Læs gratis den danske manual til Panasonic LX101 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 12 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 6.5 anmeldelser. Har du et spørgsmål om Panasonic LX101, eller vil du spørge andre brugere om produktet?

Side 1/4
CAUTIONS2
CME-LX100 No.2137-00
LX-100
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if an AC
power supply is directly connected, the sensor may get burnt or damaged.
In case noise generating equipment (switching regulator, inverter mo-
tor, etc.) is used in the vicinity of this product, connect the frame ground
(F.G.) terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power
supply is switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the sensor.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Take care that the sensor is not directly exposed to fluorescent light
from a rapid-starter lamp or a high frequency light device.
If the surface of the sensing object has a shine,
mount the sensor inclining approx. 10 to 15 degrees
against the sensing object.
Do not touch the lens of the sensor by hand directly. If
the lens becomes dirty, wipe it off with a soft cloth gently.
When the inside lens is steamed up, unscrew the
lens to get rid of the condensation.
For bLX-101-غ-Z,
e sure to use the optional cable with connector.
Extension up to total 100m is possible with 0.3mm
2, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor, dust, etc., or
where it may come in direct contact with water, or corrosive gas.
Take care that the product does not come in direct contact with water,
oil, grease, or organic solvents, such as, thinner, etc.
Make sure that stress by forcible bend or pulling with
76N, or more, force
is not applied directly to the sensor cable joint.
This sensor cannot be used in an environment containing inflammable
or explosive gases.
Never disassemble or modify the sensor.
INSTRUCTION MANUAL
Digital Mark Sensor
Photoelectric Sensor
Thank you very much for using SUNX products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel
protection.
In case of using sensing devices for personnel protec-
tion, use products which meet standards, such as
OSHA, ANSI or IEC etc., for personnel protection ap-
plicable in each region or country.
٨
٨
WARNIN
G
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
٨
1015
SPECIFICATIONS1
Notes: 1)
2)
The connector type is 100mA.LX-101غ-Z
The connecting cable is not supplied as an accessory for the connector type
LX-101غ-Z. Make sure to use the optional cables with connector below:
CN-24B-C2 CN-24BL-C2(Straight type, 4-core, Cable length: 2m) (Elbow type, 4-core, Cable length: 2m)
CN-24B-C5 CN-24BL-C5(Straight type, 4-core, Cable length: 5m) (Elbow type, 4-core, Cable length: 5m)
Max. sink current: 50mA
Applied voltage: 30V DC or less
(between output 2 and 0V)
Residual voltage: 1.5V or less
(at 50mA sink current)
NPN
open-collector transistor
<NPN output type>
Max. source current: 50mA
Applied voltage: 30V DC or less
(between output 2 and +V)
Residual voltage: 1.5V or less
(at 50mA source current)
PNP
open-collector transistor
<PNP output type>
Incorporated
Incorporated OFF-delay timer/ON-delay timer, switchable either effective or ineffective
'RUN': Green LED, 'TEACH', 'ADJ', 'COLOR', 'TIMER', 'PRO': Yellow LED
MODE indicator
Response time
Operation indicator
Mark mode: 2-level teaching/Full-auto teaching, Color mode: 1-level teaching
Sensitivity setting
Incorporated
IP67 (IEC)
4 digits red LED display
Orange LED (lights up when output 1 is ON)
Mark mode: 45Ǵs or less, Color mode: 150Ǵs or less
Digital display
Timer function
Protection
Fine sensitivity adjustment function
Material
Ambient temperature
120g approx. 55g approx.Weight
Enclosure: PBT, Display: Polycarbonate, Operation buttons: Silicon rubber, Lens: Glass
0.2mm
2
5-core cabtyre cable, 2m long
Cable
35 to 85% RH, Storage: 35 to 85% RH
-10 to +55(No dew condensation or icing allowed), Storage: -20 to +70
Ambient humidity
Red/green/blue LEDEmitting element
Current consumption
Teaching input
Supply voltage
Setting distance
Output 1
(OUT)
Item
Normal mode: 750mW or less (Current consumption 30mA or less at 24V supply voltage)
EOC mode: 600mW or less (Current consumption 25mA or less at 24V supply voltage)
12 to 24V DC+/-10% Ripple P-P10% or less˴
10mm 3mmr
Low (ON): 0 to 2V DC
Source current 0.5mA or less
Input impedance 10k approx.ǡ
High (OFF): 5V to +V DC, or open
<NPN output type>
High (ON): 5V to +V DC
Sink current 0.5mA or less
Input impedance 10k approx.ǡ
Low (OFF): 0 to 0.6V DC, or open
<PNP output type>
Max. sink current: 50mA (Note 1)
Applied voltage: 30V DC or less
(between output 1 and 0V)
Residual voltage: 1.5V or less
㨇 㨉at 50mA (Note 1) sink current
NPN open-collector transistor
<NPN output type>
Max. source current: 50mA (Note 1)
Applied voltage: 30V DC or less
(between output 1 and +V)
Residual voltage: 1.5V or less
㨇 㨉at 50mA (Note 1) source current
<PNP output type>
PNP open-collector transistor
LX-101-P-ZLX-101-P
LX-101-ZLX-101
Connector typeCable type
NPN output
PNP output
Type
Model
No.
Mark mode: Light-ON/Dark-ON Auto-setting method on teaching,
Color mode: Coincidence-ON/
Non-coincidence-ON
Output operation
Incorporated
Short-circuit protection
Inverted operation of the output 1
Output operation
Short-circuit protection
Output 2 (Inversion output)
(OUT)
MOUNTING3
PART DESCRIPTION
4
I/O CIRCUIT DIAGRAMS5
Notes: 1)
2)
The output 2 is not incorporated to connector type LX-101غ-Z.
The current of the connector type is 100mA.LX-101غ-Z
NPN output type
D2
10kǡ
D1
1
4
12 to 24V DC
r10%
Terminal No. of Connector Color code of cable type/cable with
connector
(Brown) +V
(Black) Output 1
50mA max. (Note 2)
50mA max. (Note 2)
(White) Output 2
(Note 1)
3
Z
D1
Z
D2
(Blue) 0V
Tr1
Tr2
(Pink) Teaching input
*1
5V
2
Sensor circuit
Users' circuitInternal circuit
Load Load
Do not make the
sensor detect an
object in this di-
rection because it
may cause unsta-
ble operation.
Good
No good
Care must be taken regarding the
sensor mounting directrion with
respect to the object's direction of
movement.
The tightening torque should be
0.8Nm or less.
Sensor mounting
bracket
MS-LX-1
(Optional)
M4 screw with washers
COLOR
TIMER
OPE.
RUN
ADJ.
TEACH
Operation indicator
(Orange)
MODE/CANCEL key
OFF/ENTER key
ON/SELECT key
MODE indicator / RUN (Green)
MODE indicator / ADJ (Yellow)
MODE indicator / TEACH (Yellow)
MODE indicator /
TIMER
(Yellow)
MODE indicator /
COLOR (Yellow)
MODE indicator /
PRO
(Yellow)
Digital display (Red)
PNP output type
DIRECT CODE DISPLAY8
When MODE indicator/RUN (green) lights up, the
direct code is displayed on the digital display by
pressing 'MODE/CANCEL key' for more than 2
seconds. (The direct code is turned off when stop pressing the 'MODE/CANCEL key'. )
The current setting status can be confirmed at a glance with the direct code.
Direct code
Direct
code
STANDARD
---P
(Displayed
in percent-
age)
ON
FULL lock
Without timer
1ms
2ms
5ms
10ms
20ms
50ms
100ms
200ms
500ms
Without timer
Without timer
OFF-Delay
OFF-Delay
OFF-Delay
ON-Delay
ON-Delay
ON-Delay
RUN
TEACHIN
RUN
ADJUST
OFF OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
Mark mode
(GREEN)
Mark mode
(BLUE)
Mark mode
(RED)
Color mode
Light-ON
Light-ON
Light-ON
Dark-ON
Dark-ON
Dark-ON
C o i n c i-
dence ON
I n c o i n c i-
dence ON
COARSE
FINE
COARSE
FINE
COARSE
COARSE
FINE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
COARSE
FINE
1st figure 2nd figure 3rd figure 4th figure
Timer
period
Display
mode
Eco
mode
Display invert-
ing mode
Operation
mode
Mark/color
mode
Key lock
mode
Timer
mode
Sensing
mode
MARK/COLOR MODE SETTING
7
This product enables to select the applicable
mark/color mode depending on the using purpose.
Before carrying out teaching or each setting,
set
the mark/color mode in COLOR of NAVI mode.
Since the available functions differ depending on the selected mode, take
care when setting mode. (The factory setting of this product is mark mode.)
Mark mode: Detects incident light intensity at receiving part.
Color mode:
Detects color ratio of the sensing object. This mode can
be used when desired to detect a specific color only.
The mode is selected using either 'ON/SELECT key' or 'OFF/ENTER key'.
orPress
SELECT
ON
ENTER
OFF
(Mark mode) (Color mode)
Notes: 1)
2)
The inverting output is not incorporated to connector type LX-101غ-Z.
The current of the connector type LX-101غ-Z is 100mA.
*1
Non-voltage contact or NPN transistor input
Low (ON): 0 to 2V DC
High (OFF): 5V to +V, or open
or
*2
Non-voltage contact or PNP transistor input
High (ON): 5V to +V DC
Low (OFF): 0 to 0.6V DC, or open
or
+V
0V
OPERATION PROCEDURE6
Layout of connector pin of connector type LX-101 -Zغ
Symbols... D1, D2, 3,D D4: Reverse supply polarity protection diode
ZD1, ZD2, ZD3, ZD4: Surge absorption zener diode
Tr1, Tr2: NPN output transistor
Tr3, Tr4: PNP output transistor
1 4
3
2
0V
+V
Teaching input
Output 1
Before performing teaching or each detail setting, perform the setting of either
mark mode or color mode with mark/color mode setting of NAVI mode.
Press 'MODE/CANCEL key' to conrm.Note :
1
Z
D3
Z
D4
12 to 24V DC
r10%
(Pink) Teaching input
*2
D4
D3
10kǡ
4
3
Tr3
Tr4
50mA max. (Note 2)
(Blue) 0V
0V
2
Terminal No. of Connector Color code of cable type/cable with
connector
(Brown) V
Sensor circuit
(Black) Output 1
(White) Output 2
(Note 1)
Users' circuitInternal circuit
Load Load
NAVI mode
RunRUN
At mark mode setting:
Indicates the absolute value of emitting amount. It is possible to indicate the
relative value (percent value) against threshold value.
At color mode setting:
Indicates color matching degree with relative value.
At mark mode setting:
Sets the threshold value by '2-level teaching' or 'full-auto teaching'.
At color mode setting:
Sets the threshold value by '1-level teaching'.
Refer to ' '.TEACHING MODETeachingTEACH
At mark mode setting: Allows fine adjustment of the threshold value.
At color mode setting: Allows adjustment of sensing tolerance value.
Adjust
ADJ
COLOR
Sets mark mode or color mode.
Configures operation of the timer.
TIMER
Refer to ' '.ADJUST MODE
Mark/Color mode setting
Refer to ' MARK/COLOR MODE SETTING '.
Timer operation setting
Refer to ' TIMER OPERATON SETTING MODE'.
Press
Press
Press
Press
Press
10
11
7
PRO
Allows various detailed settings to be configured.
PRO
Refer to ' PRO MODE'.
13
For details, refer to ' '.PRO MODENote :
13
12
KEY LOCK FUNCTION9
The key operation is locked by pressing both
'MODE/CANCEL key' and 'OFF/ENTER key' for
more than 2 seconds simultaneously when
MODE indicator/RUN (green) lights up.
In order to release the key lock, press both 'MODE/CANCEL key' and
'OFF/ENTER key' for more than 2 seconds again.
COLOR
If stable sensing becomes impossible by environmental effect etc., carry out
the teaching again.
Note :
TEACHING MODE
10
The teaching setting can be done when MODE
indicator/TEACH (yellow) lights up.
T
he applicable teaching for mark mode and color mode
is differed in the teaching mode as shown below:
Mark mode : Sets either 2-level teaching or full-auto teaching.
Color mode: Sets 1-level teaching
COLOR
< >In case of 2-level teaching
Press 'MODE/CANCEL key' to light up 'MODE indica-
tor/TEACH (yellow)'.
When setting the output to ON with mark, press 'ON/SELECT
key' while aligning the beam spot, and when setting the
output to OFF, press 'OFF/ENTER key. ' ' blinks.
COLOR
or
COLOR
COLOR
COLOR
In case of mark mode
Align the beam spot to the base (non-mark area) of the mark
to be detected. When 'ON/SELECT key' is pressed at the
step , press 'OFF/ENTER key, and when 'OFF/ENTER
key' is pressed at the step , press 'ON/SELECT key'.
' ' blinks.
The threshold value is set at the mid-value between the step
and .
' ' is displayed on the
digital display.
' ' is displayed on the
digital display.
In case stable sensing is possible :
In case stable sensing is impossible:
50mA max. (Note 2)