PCE Instruments PCE-BPD-P-66A Manual

PCE Instruments Måling PCE-BPD-P-66A

Læs gratis den danske manual til PCE Instruments PCE-BPD-P-66A (32 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-BPD-P-66A, eller vil du spørge andre brugere om produktet?

Side 1/32
Impulse counters and ratemeters
Big panel displays with impulse counter, ratemeter and periodmeter funcons. Dierent formats avail-
able with 60 mm and 100 mm digit height, 4 and 6 digits, in red color. Sturdy metal housing, with full
IP65 protecon, designed for panel, wall or hanging mount. Versale and congurable, accepts all types
of impulse signals (NPN, PNP, Namur, TTL, inducve, mechanical, encoders, ...), provides excitaon volt
-
age to power the transducer, congurable fast access menu, ‘on power up’ funcon, password and 5
congurable brightness levels
. Universal AC and DC power. Accepts up to 3 output and control opons
(relays, analog retransmission, Modbus RTU, transistor outputs, RS-485 ASCII, ...). Conguraon from
frontal keypad or remote keypad.
BIG PANEL DISPLAYS
5534r03
User’s Manual
PCE-BPD-P
www.pce-instruments.com
2
PCE Instruments
1. Large display PCE-BPD-P
Big panel displays with impulse counter, ratemeter and periodmeter funcons
Big panel displays for long distance reading, for industrial
applicaons. Dierent formats available with 4 and 6 digits,
with 60 mm and 100 m digit height. Front keypad to access
the conguraon menu, and oponal remote keypad.
Instruments with 5 impulse counter modes (see secon
1.13.3), 2 ratemeter modes (see secon 1.13.9) and 1 peri
-
odmeter mode (see secon 1.13.9).
Highly congurable, accepts all types of sensors (NPN,
PNP, push-pull, Namur, inducve, pick-up, mechanical, TTL,
CMOS, ...) including single and bidireconal encoder signals.
Reading from 999999 to -199999 (or 9999 to -1999 for 4 digit
formats) with congurable decimal point, scalable reading
with congurable mulplier (1 to 999999) and divider factors
(1 to 999999). Includes internal pull-up and pull-down resis
-
tors, congurable trigger levels, detecon by rising or falling
edge, excitaon voltage congurable from 5 Vdc to 18 Vdc.
Output and control opons with 1, 2 and 3 relays, transis
-
tor outputs, controls for SSR relays, isolated analog outputs,
communicaons in Modbus RTU, RS-485 ASCII and RS-232.
Sturdy metal housing with full IP65 protecon. Internal
connecons by plug-in screw clamp terminals, and output
through cable glands. Housing prepared for panel, wall and
hanging mount.
Congurable Fast accessto selected funcons with key
‘UP’ (5) (see secon 1.13.17)
On power upfor system protecon on ‘cold’ start-up and 
control of alarm status (see secon 1.13.18)
FAST mode for fast counter applicaons (see secon
1.13.3)
SLOWmode for ratemeters applicaons at low frequen
-
cies (slow applicaons) (see secon 1.13.9)
Easy conguraon for most usual sensors at the SnSr /
Auto’ menu (see secon 1.13.14)
alarms with 1 or 2 setpoints, independent acvaon and
deacvaon delays, hysteresis, manual unlocking, ... (see
secon 1.13.15)
Mulple display lters, memory of maximum and minimum
reading, password protecon, 5 brightness levels.
1. Idenfy the instrument format (see secon 1.4)
2. Power and signal connecons
- open the instrument (see secon 1.5)
- connect the power (see secon 1.7)
- connect the signal (see secon 1.8)
- close the instrument (see secon 1.5)
3. Congure the instrument (see secon 1.13)
- select the main funcon, and the decimal point posion
(see secon 1.13.2)
- congure the main funcon selected (see secon 1.13.2)
• counter modes from secon 1.13.3
• ratemeter and periodmeter from secon 1.13.9
- congure the sensor (see secon 1.13.13)
1.1 How to use this manual
If this is the rst me you are conguring big panel display,
below are the steps to follow to install and congure the in-
strument. Read all the manual secons in order to have a
full and clear view of the characteriscs of the instrument.
Do not forget to read the installaon precauons at secon
1.17.
4. Advanced conguraon (oponal)
- congure the instrument alarms (see secon 1.13.15)
- congure the fast access (see secon 1.13.17), on power
up’ (1.13.18), key ‘LE’ (1.13.19) and password (1.13.26)
5. If the instrument includes analog output or serial commu
-
nicaons
- to include an opon to an instrument see secon 1.6
- to congure an installed opon, access the opon con
-
guraon menu (see secon 1.13.30)
6. Install the instrument
- mount on panel, wall or hanging (see secon 1.16)
- adjust the brightness level according to your environmen
-
tal needs (see secon 1.13.29)


Produkt Specifikationer

Mærke: PCE Instruments
Kategori: Måling
Model: PCE-BPD-P-66A

Har du brug for hjælp?

Hvis du har brug for hjælp til PCE Instruments PCE-BPD-P-66A stil et spørgsmål nedenfor, og andre brugere vil svare dig