Læs gratis den danske manual til PCE Instruments PCE-BPD-P-66A (32 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 2 anmeldelser. Har du et spørgsmål om PCE Instruments PCE-BPD-P-66A, eller vil du spørge andre brugere om produktet?

Side 1/32
Impulse counters and ratemeters
Big panel displays with impulse counter, ratemeter and periodmeter funcons. Dierent formats avail-
able with 60 mm and 100 mm digit height, 4 and 6 digits, in red color. Sturdy metal housing, with full
IP65 protecon, designed for panel, wall or hanging mount. Versale and congurable, accepts all types
of impulse signals (NPN, PNP, Namur, TTL, inducve, mechanical, encoders, ...), provides excitaon volt
-
age to power the transducer, congurable fast access menu, ‘on power up’ funcon, password and 5
congurable brightness levels
. Universal AC and DC power. Accepts up to 3 output and control opons
(relays, analog retransmission, Modbus RTU, transistor outputs, RS-485 ASCII, ...). Conguraon from
frontal keypad or remote keypad.
BIG PANEL DISPLAYS
5534r03
User’s Manual
PCE-BPD-P
www.pce-instruments.com
2
PCE Instruments
1. Large display PCE-BPD-P
Big panel displays with impulse counter, ratemeter and periodmeter funcons
Big panel displays for long distance reading, for industrial
applicaons. Dierent formats available with 4 and 6 digits,
with 60 mm and 100 m digit height. Front keypad to access
the conguraon menu, and oponal remote keypad.
Instruments with 5 impulse counter modes (see secon
1.13.3), 2 ratemeter modes (see secon 1.13.9) and 1 peri
-
odmeter mode (see secon 1.13.9).
Highly congurable, accepts all types of sensors (NPN,
PNP, push-pull, Namur, inducve, pick-up, mechanical, TTL,
CMOS, ...) including single and bidireconal encoder signals.
Reading from 999999 to -199999 (or 9999 to -1999 for 4 digit
formats) with congurable decimal point, scalable reading
with congurable mulplier (1 to 999999) and divider factors
(1 to 999999). Includes internal pull-up and pull-down resis
-
tors, congurable trigger levels, detecon by rising or falling
edge, excitaon voltage congurable from 5 Vdc to 18 Vdc.
Output and control opons with 1, 2 and 3 relays, transis
-
tor outputs, controls for SSR relays, isolated analog outputs,
communicaons in Modbus RTU, RS-485 ASCII and RS-232.
Sturdy metal housing with full IP65 protecon. Internal
connecons by plug-in screw clamp terminals, and output
through cable glands. Housing prepared for panel, wall and
hanging mount.
Congurable Fast accessto selected funcons with key
‘UP’ (5) (see secon 1.13.17)
On power upfor system protecon on ‘cold’ start-up and 
control of alarm status (see secon 1.13.18)
FAST mode for fast counter applicaons (see secon
1.13.3)
SLOWmode for ratemeters applicaons at low frequen
-
cies (slow applicaons) (see secon 1.13.9)
Easy conguraon for most usual sensors at the SnSr /
Auto’ menu (see secon 1.13.14)
alarms with 1 or 2 setpoints, independent acvaon and
deacvaon delays, hysteresis, manual unlocking, ... (see
secon 1.13.15)
Mulple display lters, memory of maximum and minimum
reading, password protecon, 5 brightness levels.
1. Idenfy the instrument format (see secon 1.4)
2. Power and signal connecons
- open the instrument (see secon 1.5)
- connect the power (see secon 1.7)
- connect the signal (see secon 1.8)
- close the instrument (see secon 1.5)
3. Congure the instrument (see secon 1.13)
- select the main funcon, and the decimal point posion
(see secon 1.13.2)
- congure the main funcon selected (see secon 1.13.2)
• counter modes from secon 1.13.3
• ratemeter and periodmeter from secon 1.13.9
- congure the sensor (see secon 1.13.13)
1.1 How to use this manual
If this is the rst me you are conguring big panel display,
below are the steps to follow to install and congure the in-
strument. Read all the manual secons in order to have a
full and clear view of the characteriscs of the instrument.
Do not forget to read the installaon precauons at secon
1.17.
4. Advanced conguraon (oponal)
- congure the instrument alarms (see secon 1.13.15)
- congure the fast access (see secon 1.13.17), on power
up’ (1.13.18), key ‘LE’ (1.13.19) and password (1.13.26)
5. If the instrument includes analog output or serial commu
-
nicaons
- to include an opon to an instrument see secon 1.6
- to congure an installed opon, access the opon con
-
guraon menu (see secon 1.13.30)
6. Install the instrument
- mount on panel, wall or hanging (see secon 1.16)
- adjust the brightness level according to your environmen
-
tal needs (see secon 1.13.29)