The following symbols may appear on the product:
This symbol means read the instructions for use, before
using the appliance (Fig. 2).
This symbol means to use the indicated power supply
1 Align the brush head so the bristles point in the same
direction as the front of the handle (Fig. 4).
2 Press the brush head down onto the metal shaft until
there is a small 1-2 mm gap (Fig. 5).
Note: It is normal to see a slight gap between the brush
head and the handle. This allows the brush head to
Charging your Philips Sonicare
1 Place the power toothbrush handle on the charger
2 Connect the charger to a 5V USB wall adapter.
3 Your toothbrush continues to charge until it is fully
-When the toothbrush is charging, the battery
indicator pulsates green.
-When fully charged, the battery indicator will light
up solid green for 30 seconds before turning o.
Note: It can take up to 10 hours to fully charge the
battery, but you can use the toothbrush before it is fully
Using your Philips Sonicare toothbrush
If you are using your Sonicare toothbrush for the rst
time, it is normal to feel more vibration than when using
a non-electric toothbrush. It is common for rst time
users to apply too much pressure. Only apply gentle
pressure and let the toothbrush do the brushing for you.
Please follow brushing instructions below for the best
1 Wet the bristles and apply a small amount of
2 Place the toothbrush bristles against the teeth at a
slight angle (45 degrees) (Fig. 7). The handle has two
45 - degree indication bars to help guide your Bass
brushing technique. Press the brush head gently
against the gum to make the bristles reach the gum
line or slightly beneath the gum line (Fig. 8).
3 Press the power on/o button to turn on the Philips
Note: Keep the center of the brush in contact with the
4 Gently keep the bristles placed on the teeth and in
the gumline. Brush your teeth with small back and
forth motion so the bristles reach between the teeth.
Continue this motion throughout your brushing cycle.
Note: The bristles should slightly are. Do not scrub. It is
not recommended to scrub as you would with a manual
5 To clean the inside surfaces of the front teeth, tilt the
brush handle semi-upright and make several vertical
overlapping brushing strokes on each tooth (Fig. 9).
Note: To make sure you brush evenly throughout the
mouth, divide your mouth into 4 sections using the
QuadPacer feature (see chapter ‘Features’).
6 Begin brushing in section 1 (outside upper teeth) and
brush for 30 seconds before you move to section 2
(inside upper teeth). Continue brushing in section 3
(outside lower teeth) and brush for 30 seconds before
you move to section 4 (inside lower teeth) (Fig. 10).
7 After you have completed the brushing cycle, you can
spend additional time brushing the chewing surfaces
of your teeth and areas where staining occurs. You
can also brush your tongue, with the toothbrush
turned on or o, as you prefer (Fig. 11).
Your Philips Sonicare toothbrush should be safe to use
on braced (brush heads wear out sooner when used on
braces) and dental restorations (llings, crowns, veneers)
if they are properly adhered and not compromised.
If a problem occurs, please follow up with a dental
This Philips Sonicare toothbrush is designed to provide
at least 80 brushing sessions after fully charged for 10
hours, each session lasting 2 minutes. When the battery is
low, the battery indicator starts to ash amber.
Note: When the battery is completely empty, the
toothbrush switches o. Place the handle on the charger
Note: To keep the battery fully charged at all times,
you may keep your Philips Sonicare toothbrush on the
Note: Battery usage time is expected to reduce over
Your power toothbrush is equipped with three dierent
For exceptional everyday cleaning (2 minutes).
For invigorating and thorough cleaning (3 minutes).
For gentle cleaning of gums (2 minutes).
Note: When you use the toothbrush for the rst time, the
To toggle between the brushing modes:
-Press the power on/o button once to turn on the
-Press a second time to change the within 2 seconds
-After the toothbrush has been on for more than 2
seconds, if you want to change modes, you'll need to
pause the toothbrush rst (click the mode button),
then press the mode button .within 2seconds
This Philips Sonicare model comes with the EasyStart
feature activated. The EasyStart feature gently increases
the power over the rst 14 brushings to help you get
used to brushing with the Philips Sonicare. The EasyStart
feature works with Clean mode only.
To deactivate EasyStart see 'Activating or deactivating
The Smartimer indicates that your brushing cycle is
complete by automatically turning o the toothbrush at
the end of the brushing cycle.
Dental professionals recommend brushing no less than 2
The Quadpacer is an interval timer that beeps every
30 seconds to remind you to brush all teeth evenly by
dividing your mouth into 4 sections (Fig. 10).
Your Sonicare toothbrush measures the pressure you
apply while brushing to protect your gums and teeth
If you apply excess pressure, the handle changes its
vibration until you reduce the pressure.
Activating or deactivating features
You can activate or deactivate the following features of
-Pressure Sensor Feedback
To activate or deactivate these features, follow the
1 Put the handle on the plugged-in charger.
2 Keep the power on/o button pressed until you hear
3 Release the power on/o button.
-Triple tone of low-medium-high means the
EasyStart feature has been activated. The battery
indicator blinking green twice shows the EasyStart
-Triple tone of high-medium-low means the
EasyStart feature has been deactivated. The
battery indicator blinking amber once shows the
EasyStart is deactivated.
Note: To achieve optimal ecacy, EasyStart needs to be
1 Put the handle on the plugged-in charger.
2 Keep the power on/o button pressed until you hear
3 Release the power on/o button.
-Triple tone of low-medium-high means the
Pressure Sensor Feedback feature has been
activated. The battery indicator blinking green
twice shows the Pressure Sensor Feedback is
-Triple tone of high-medium-low means the
Pressure Sensor Feedback feature has been
deactivated. The battery indicator blinking amber
once shows the Pressure Sensor Feedback is
You should clean your Philips Sonicare toothbrush
regularly to remove toothpaste and other residue. Failure
to clean your Philips Sonicare toothbrush may result in an
unhygienic product and damage to it may occur.
Warning: Do not clean brush heads, the handle or
the charger in the dishwasher.
Warning: Do not clean with boiling hot water.
1 Remove the brush head and rinse the metal shaft area
with warm water (Fig. 12). Make sure you remove any
Caution: Do not push on the rubber seal on the metal
shaft with sharp objects, as this may cause damage.
2 Wipe the entire surface of the handle with a damp
Caution: Do not tap the handle on the sink to remove
1 Rinse the brush head and bristles after each use
2 Remove the brush head from the handle and rinse the
brush head connection with warm water at least once
1 Unplug the charger before you clean it.
2 Wipe the surface of the charger with a damp cloth.
If you are not going to use the product for a long time,
unplug it, clean it (see chapter 'Cleaning') and store it in a
cool and dry place away from direct sunlight.
Replace Philips Sonicare brush heads every 3 months
to achieve optimal results. Use only Philips Sonicare
Locating the model number
Look on the bottom of the Philips Sonicare toothbrush
handle for the model number HX507x.
This chapter summarizes the most common problems you
could encounter with the appliance. If you are unable
to solve the problem with the information below, visit
www.philips.com/support for a list of frequently asked
questions or contact the Consumer Care Center in your
Problem Possible cause Solution
Problem Possible cause Solution
If you need information or support, please visit
www.philips.com/support or read the international
The terms of the international warranty do not cover the
-Damage caused by use of unauthorized replacement
-Damage caused by misuse, abuse, neglect, alterations
-Normal wear and tear, including chips, scratches,
abrasions, discoloration or fading.
-This symbol means that electrical products and
batteries shall not be disposed of with normal
household waste (Fig. 14).
-Follow your country’s rules for the separate collection
of electrical products and batteries.
Removal of built-in rechargeable
CONTAINS LITHIUM ION RECHARGEABLE CELL. MUST BE
RECYCLED OR DISPOSED OF PROPERLY.
The built-in rechargeable battery must only be removed
by a qualied professional when the appliance is
discarded. Before removing the battery, make sure that
the appliance is disconnected from the wall socket and
that the battery is completely empty.
Take any necessary safety precautions when you
handle tools to open the appliance and when you
dispose of the rechargeable battery. Be sure to
protect your eyes, hands, ngers, and the surface
When you handle batteries, make sure that your
hands, the product and the batteries are dry.
To avoid accidental short-circuiting of batteries
after removal, do not let battery terminals
come into contact with metal objects (e.g.
coins, hairpins, rings). Do not wrap batteries in
aluminum foil. Tape battery terminals or put
batteries in a plastic bag before you discard them.
Only remove the rechargeable battery when you discard
the product. Before you remove the battery, make sure
that the product is disconnected from the wall socket and
that the battery is completely empty.
1 Remove the inner body from the handle.
2 Remove the rechargeable battery from the inner
www.philips.com/welcome 上注册
Congratulations on your purchase and welcome
to Philips! To fully benet from the support
that Philips oers, register your product at
Important safety information
Only use the product for its intended purpose. Read this
information carefully before you use the product and its
batteries and accessories, and save it for future reference.
Misuse can lead to hazards or serious injuries.
-Only use original Philips accessories or consumables.
If supplied, only use the original USB cable and USB
-This appliance contains no user-serviceable parts. If
the appliance is damaged, stop using it and contact
the Consumer Care Center in your country (see
-If the USB cable or USB power supply unit is damaged,
-Keep the charger away from water.
-After cleaning, make sure the charger is completely
dry before you connect it.
-Do not clean any part of the product in the
-Rinse the handle, especially the brush head
connection. Gently clean around the rubber seal.
-Make sure the handle is completely dry before you
-This appliance can be used by children and persons
with reduced physical, sensory or mental capabilities
or lack of experience and knowledge if they have
been given supervision or instruction concerning use
of the appliance in a safe way and understand the
hazards involved. Cleaning and user maintenance
shall not be made by children without supervision.
-Children should be supervised to ensure that they do
not play with the product.
-Do not use adapters and chargers outdoors or near
-This appliance has only been designed for cleaning
-Replace the brush head every 3 months or sooner if
signs of wear appear. Stop using a brush head with
crushed or bent bristles.
-If your toothpaste contains peroxide, baking soda
or bicarbonate (common in whitening toothpastes),
thoroughly clean the brush head with soap and water
after each use. This prevents possible cracking of the
-Avoid direct contact with products that contain
essential oils or coconut oil. Contact may result in
-The maximum altitude of use is 4500 meters.
-This appliance is a personal care device and is not
intended for use on multiple persons.
-Stop using the appliance and consult your dentist/
doctor if excessive or prolonged bleeding occurs after
use, or if you experience discomfort or pain during
-If you have a pacemaker or other implanted device,
contact your doctor or the manufacturer of the
implanted device prior to use.
Battery safety instructions
-This appliance contains batteries that are only
removable by skilled persons.
-Only use the product for its intended purpose. Read
this information carefully before you use the product
and its batteries and accessories, and save it for future
reference. Misuse can lead to hazards or serious
injuries. Accessories supplied may vary for dierent
-Only use original Philips accessories and consumables.
-To charge the product, only use a certied safety extra
low voltage (SELV) supply unit with output rating
5 V, ≥2W. If you need support nding the correct USB
supply unit, contact the Consumer Care Center in your
country (see the international warranty leaet for
contact details). Using a non-certied supply unit may
cause hazards or serious injuries.
-Charge, use and store the product at a temperature
-Keep product and batteries away from re and do not
expose them to direct sunlight or high temperatures.
-If the product becomes abnormally hot or smelly,
changes color or if charging takes longer than usual,
stop using and charging the product and contact
-Do not place products and their batteries in
microwave ovens or on induction cookers.
-Do not open, modify, pierce, damage or dismantle the
product or battery to prevent batteries from heating
up or releasing toxic or hazardous substances. Do not
short-circuit, overcharge or reverse charge batteries.
-If batteries are damaged or leaking, avoid contact
with the skin or eyes. If this occurs, immediately rinse
well with water and seek medical care.
-This appliance contains batteries that are non-
replaceable. When the battery is at end of life, the
appliance shall be properly disposed of, see section on
Storage and transportation conditions
Temperature -10°C to +60°C (14 °F to 140 °F).
Electromagnetic elds (EMF)
This Philips appliance complies with all applicable
standards and regulations regarding exposure to
Your Philips Sonicare (Fig. 1)
4 Power on/o and mode button
Note: Appearance may slightly dier, depending on the
Note: Wall adapter not included. You can use any
compatible IPX4 splash-proof adapter (identiable by the
"IPX4" text or symbols on the adapter).
300014409641_Venus Youth IFU_GC.indd 1
300014409641_Venus Youth IFU_GC.indd 1
300014409641_Venus Youth IFU_GC.indd 1
300014409641_Venus Youth IFU_GC.indd 1300014409641_Venus Youth IFU_GC.indd 1
2024/12/19 11:05:54
2024/12/19 11:05:54
2024/12/19 11:05:54
2024/12/19 11:05:542024/12/19 11:05:54