
This product MUST be used responsibly.
Please read these Instructions carefully
Refer to your Information Guide for:
• SECURITYBUTTONSEQUENCE
• WHYISASERIESOFTREATMENTS
• YOURQUESTIONSANSWERED
SCANNING HAIR REMOVER x60
• Readallinstructionsthoroughlyandretainforfuturereference.
• Not suitable for Afro-Caribbean, black skincomplexions or forGreyHair.
See“SuitableSkinTypes”inInformationGuide.
• Laserhairremovalshouldnotcausediscomfort,youmayfeelindividualhairs
beingtreated,whichislikeamildpinprick,andaslightwarmingofthearea.
Ifyoufeelanydiscomfortorsorenessthesettingmaybetoohigh.
• Inbuiltsafety featuresprotecttheeyebeing exposedtothelaser,however,
neveraimtheWandatorneareyes.
• DoNOTusenearflammablematerials.
• Keeptheproductoutofreachofchildrenandpets.
• ReflectionHazard:Pleaseremovealljewelleryinthevicinityofthetreatment
• Whennotinuse,storethekeyresponsiblyinasafeplaceawayfromchildren.
• Donottreatthesamehairrepeatedlyinanyonesession.
• Donotuseafterdrinkingalcoholorifyouarefeelingunwellorfatigued.
• Donottreatthefollowingareas:tattoos,permanentmake-up,pimples,warts,
haironblackspotsormoles,darkfreckles,skindisease,birthmarks,burns,
lips,nipples,genitalor analareas,eczema,eyelashes,eyebrows, nearthe
• Thisisa sensitivelaser scanningproduct.Careshouldbetakentoavoid
damagetothemechanismintheWand.
• This appliance is not intended for use bypersonswithreduced physical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unless
they have been given supervision or instruction concerning use of the
appliancebyapersonresponsiblefortheirsafety.
• DoNOT dismantleorrepair.Ifyou haveany problemsusingtheproduct,
contactourCustomerCareDepartment.
• Misuseoftheunitcancauseharm.
• DoNOToverrideanysafetyfeaturesoropentheunitorwand.
• OnlyusethisproductwiththeMainsAdaptersupplied.
• KeepWandawayfromstrongelectromagneticfieldsandmagnetsduringuse.
IMPORTANT:24hoursbeforetreatmentitisveryimportanttodoapatchtest.
Thepatchtestwillconfirmthemaximumpowerlevelforyourskintype.Eacharea
tobetreatedmustbecheckedasskincolourcanvary.Pleaserefertothe‘PATCH
TEST’sectionintheInformationGuideandontheDVDforinstructions.
Aslightrednessmayoccur,butnot always,withinanhouroftreatment.This
localisedrednessiscausedbythedestructionofthehairfolliclesandisquite
normal.However,ifanyrednessremainsafter24hoursthiswouldindicatethe
powerlevelselectedwastoohighforyourskintype.
Please ensure you read the Information Guide and understand the
‘Warnings’ and ‘Product Safety’ sections before proceeding.
• Shavetheareatobetreated.Thisensuresthatthelasergoesdirectly
tothehairrootandavoidshairburningonthesurface.
• Removealljewelleryinthevicinityofthetreatmentarea.
• Pleaseensureyouhavepatchtestedtheareatobetreated24hours
ConnectMainsAdapterintotheDCPowerSocket at
thebackoftheunitandplugintotheMains.
Unlock with Key to turn on. The light around the
Keyswitchwillflashgreen.
Enterthe“SECURITYBUTTONSEQUENCE”.
You will find the Security Button Sequence in the
ThegreenlightaroundtheKeyswitchwillfullyilluminate.
Thelightsaroundthex60SCAN,x20SCANandSINGLE
buttonswillflashbluereadyforselection.Thebottom
PowerLevelIndicatorlightwillilluminate.
Usethe+/- buttonstoselectthe correctpowerlevel
foryourskintype.Refertothe‘PatchTest’sectionof
theInformationGuideforskintypes.
Each time the power setting is adjusted, you will
need to reselect x60 SCAN, x20 SCAN or SINGLE
Note: Ifno buttons are pressedafter20 minutes the Unit willenter energy
saving mode. The orange light will flash and power level1will remainon.
TorestartturnkeyoffandbackonagainandstartatStep3.
Turn the Keyswitch anticlockwise to lock the unit.
RemovetheKeytoasafeplaceawayfromchildren.
Note: Ifyouexperienceunexpectedbehaviourofthisproductthenitispossible
someexternalelectromagneticinterferenceisresponsiblee.g.electricmotors/
loudspeakersetc.Youshouldremovethis sourceandrestartthe productto
restorefulloperation.Atnotimewillthelaserfireunintentionally.
Youcanopttotreatsingle hairsusing
Press the ‘SINGLE’ button once.
TheSINGLEbuttonwillilluminateblue.
The orange light on the Wand
FollowthesameprocedureforSCANtreatmentfromStep6,butthistime
pressing the SINGLE button.
In SINGLEmode, the blue lightaround theSINGLE
Referto‘TreatmentArea’section,SINGLEmode.
Asaguidetothetreatmentarea,asmallindentationmarkwillbeleftby
pressingthe Wanddownontheskin.Inx60SCAN mode,overlapping
theindentationmarkslightlywhenmovingtheWandineachdirectionwill
ensureeffective coverage. Inx20SCANmode, overlaptheindentation
SCANmodessequentiallytargetsinglehairsineachtreatment.
SINGLEmodeisfortreatingindividualhairs.Thetreatmentareaisinthe
centreoftheindentationguideandmeasures1mmx1mm.
Press the x60 SCAN button once. The
blue light around the button will fully
illuminate.Theorangelightonthewand
Alternatively,pressthex20SCANbuttononce.
Placethewandontheskinovertheareayouwishtotreat,
ensuringtheTouchPinsareincontactwiththeskin.
TheorangelightwillturnOFFandthewhite‘ready’light
Thebluelights around theSCAN button will rotate to
indicatetreatmentisreadytostart.
Press and HOLD the Laser Button on the top of the
wandtostartlasertreatment.
The white light will flash on and off to indicate laser
treatmentisinprogressandtheunitwillbeeprepeatedly
(thiscanbemuted).Youwillnotbeabletoseethelaser.
You may feel individual hairs being treated, whichis
likeamildpinprick,and aslightwarmingof thearea
Whenthe laser treatmentceases, theorangelightwill
comebackon.Youcannowmoveontothenextareaof
Whenmoving thewand tothenextarea ofhairstobe
treated the Touch Pins must beremovedbriefly from
Refertoscanmodesin‘treatmentarea’section.
IMPORTANTNOTES - please read carefully
• DoNOTmovethewandduringtreatment.Youmaynoticethewandbecomes
warmduringusethisisquitenormal.
• IfcontactislostbetweentheTouchPinsandskinduringtreatment,thewand’s
orangelightwillcomeon.Treatmentwillresumewhencontactismadeagain.
• Foryoursafety,ifthewandisnotpositionedcorrectlyontheskinsurfacefor
treatment,thewhiteandorangelightswillflashalternatelyandoperationof
thelaserwillbedisabled.
• Sometimesyou can smell faint burning or even see a very, smallline of
smokeasthehairistreated.
• Successfullytreatedhairsdonotalwaysfalloutimmediately,butare shed
over time as they are released from the hair follicle, light rubbing can
• Youmayfeela‘pinprick’sensationduringtreatment.Anylocalisedrednessafter
treatmentiscausedbythedestructionofthehairfolliclesandisquitenormal.If
anyrednessremainsafter24hoursthiswouldindicatethepowerlevelselected
wastoohighforyourskintype.Pleaserefertothe‘PatchTest’sectioninthe
InformationGuide.Anylongerlastingrednesswillalsodisappear.
L A S E R H A I R T R E A T M E N T
PresstheMUTEbuttononthebackoftheUnittoturn
offtheBeepnoises.Pressagaintoturnbackon.
Note: Thisdoesn’tturnoffwarningbleeps.
resettingafter‘lockout’
If you experience a ‘lockout’ as indicated by
repeated flashingof any ofthe bluepower lights,
simply resetby turning the unit off usingthekey,
waiting5secondsandturningtheunitonagain.
Periodically check whether there are any smoke
deposits on the Laser Aperture. A build up of
depositswillaffecttheefficiencyofthelaser.Ifyou
noticeanydeposits,switchtheunitOFFandunplug
themainsadapter.Thensimplycleanwithalintfree
clothorcottonbud,ensuringnofibresareleftinthe
Rio,Dezac,SalonLaserScanningHairRemoverx60andLaserSafeTechnologyaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2011anufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
g. Power Increase Button (+)
h. Power Decrease Button (-)