Sharp EL-501W Manual

Sharp kalkulator EL-501W

Læs gratis den danske manual til Sharp EL-501W (8 sider) i kategorien kalkulator. Denne vejledning er vurderet som hjælpsom af 23 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 12 anmeldelser. Har du et spørgsmål om Sharp EL-501W, eller vil du spørge andre brugere om produktet?

Side 1/8
EL-501W
SCIENTIFIC CALCULATOR
OPERATION MANUAL
MODEL
ENGLISH
INTRODUCTION
Thank you for purchasing the SHARP Scientific Calculator
Model EL-501W.
About the calculation examples (including some formulas
and tables), refer to the reverse side of this English manual.
Refer to the number on the right of each title on the
manual for use.
After reading this manual, store it in a convenient location for
future reference.
Operational Notes
Do not carry the calculator around in your back pocket, as
it may break when you sit down. The display is made of
glass and is particularly fragile.
Keep the calculator away from extreme heat such as on a
car dashboard or near a heater, and avoid exposing it to
excessively humid or dusty environments.
Since this product is not waterproof, do not use it or store
it where fluids, for example water, can splash onto it.
Raindrops, water spray, juice, coffee, steam, perspiration,
etc. will also cause malfunction.
Clean with a soft, dry cloth. Do not use solvents or wet
cloth.
Do not drop it or apply excessive force.
Never dispose of batteries in a fire.
Keep batteries out of the reach of children.
This product, including accessories, may change due to
upgrading without prior notice.
SHARP will not be liable nor responsible for any inciden-
tal or consequential economic or property damage caused
by misuse and/or malfunctions of this product and its
peripherals, unless such liability is acknowledged by law.
Press the RESET switch (on the back), with the tip of a
ball-point pen or similar object, only in the following cases.
Do not use an object with a breakable or sharp tip. Note
that pressing the RESET switch erases all data stored in
memory.
When using for the first time
After replacing the batteries
To clear all memory contents
When an abnormal condition occurs and all keys are
inoperative.
If service should be required on this calculator, use only a
SHARP servicing dealer, SHARP approved service facility,
or SHARP repair service where available.
Hard Case
(During actual use not all symbols are displayed at the same time.)
If the value of mantissa does not fit within the range
±0.000000001 ±9999999999, the display changes to scien-
tific notation. The display mode can be changed according to
the purpose of the calculation.
2ndF : Appears when @ is pressed, indicating that the
functions shown in orange are enabled.
HYP : Indicates that h has been pressed and the hy-
perbolic functions are enabled. If are@ H
pressed, the symbols appear, indicat-2ndF HYP
ing that inverse hyperbolic functions are enabled.
DEG/RAD/GRAD: Indicates angular units and changes each
time is pressed. The default setting is DEG.G
( ) : Appears when a calculation with parentheses is per-
formed by pressing (.
BIN : Indicates that has been pressed.@ ê
Binary system mode is selected.
OCT : Indicates that has been pressed.@ î
Octal system mode is selected.
HEX : Indicates that has been pressed.@ ì
Hexadecimal system mode is selected.
CPLX : Indicates that has been pressed.@ π
Complex number mode is selected.
STAT : Indicates that @ Æ has been pressed.
Statistics mode is selected.
M : Indicates that a numerical value is stored in the
independent memory.
E : Appears when an error is detected.
PRINTED IN CHINA / IMPRIMÉ EN CHINE / IMPRESO EN CHINA
04AGK (TINSE0496THZZ)
BEFORE USING THE CALCULATOR
Key Notation Used in this Manual
In this manual, key operations are described as follows:
To specify A (HEX): A
To specify π: @ V
To specify Exp : E
Functions that are printed in orange above the key require
@ to be pressed first before the key. Numbers are not
shown as keys, but as ordinary numbers.
Power On and Off
Press ª to turn the calculator on, and F to turn it off.
Clearing Numbers
Press ª to clear the entries except for a numerical
value in the independent memory and statistical data.
Press æ to clear the number entered prior to use of
function key.
In case of one digit correction of the entered number, press
ø (right shift key).
DISPLAY
Symbol
Mantissa Exponent
Floating point system
Scientific notation system
INITIAL SET UP
Mode Selection
Normal mode: ª
Used to perform arithmetic operations and function calcula-
tions. , , , and BIN OCT HEX CPLX STAT are not displayed.
Binary, Octal, Decimal, or Hexadecimal system mode:
@ê @î , , or
Complex number mode: @π
Used to perform arithmetic operations with complex numbers.
To clear this mode, press @π.
Statistics mode: @Æ
Used to perform statistical calculations. To clear this mode,
press @Æ.
When executing mode selection, statistical data will be cleared
even when reselecting the same mode.
By pressing or Automatic power off function, theF
mode is cleared and returned to the normal mode.
Priority Levels in Calculation
This calculator performs operations according to the following
priority:
1 Functions such as sin, x2, and %
2 yx, x¿y
3 ×, ÷
4 +, –
5 =, M+ and other calculation ending instruction
Calculations which are given the same priority level are
executed in sequence.
If parentheses are used, parenthesized calculations have
precedence over any other calculations.
Parentheses can be continuously used up to 15 times un-
less pending calculations exceed 4.
DEG ( )°
GRAD RAD (g)
100000 3=÷
[Floating point] ª / =100000 3 33333.33333
[TAB set to 2] @i 2 33333.33
[Scientific notation] 3.33 04
[Floating point] ∞@i. 33333.33333
If the value for floating point system does not fit in the
following range, the calculator will display the result using
scientific notation system:
0.000000001 | x | 9999999999
Determination of the Angular Unit
In this calculator, the following three angular units (degrees,
radians, and grads) can be specified.
Press G
(rad)
Selecting the Display Notation and Decimal Places
When calculation result is displayed in the floating point
system, pressing displays the result in the scientific
notation system.
Pressing once more displays the result again in the
floating point system.
Pressing @i and any value between 0 and 9 speci-
fies the number of decimal places in the calculation result.
To clear the setting of decimal places, press @ i
..
SCIENTIFIC CALCULATIONS
Calculate in the normal mode.
In each example, press ª to clear the display.
Arithmetic Operations
The closing parenthesis ) = ; just before or
may be omitted.
When entering only a decimal place, it is not necessary to
press 0 before ..
Random Numbers
A pseudo-random number with three significant digits can be
generated by pressing @ ` . Random number gen-
eration is not possible when binary/octal/hexadecimal sys-
tem mode is set.
Angular Unit Conversions
Each time are pressed, the angular unit changes@ g
in sequence.
Memory Calculations
This calculator has one independent memory (M). It is avail-
able in the normal mode and binary, octal, hexadecimal
system mode.
The independent memory is indicated by the three keys:
O R ;, , .
Before starting a calculation, clear the memory by press-
ing ª and O.
A value can be added to or subtracted from an existing
memory value. When subtracting a number from the
memory, press ± and ;.
The contents of the memory are retained even when the
calculator is turned off. A value stored in memory will thus
remain until it is changed or until the batteries run out.
Chain Calculations
This calculator allows the previous calculation result to be
used in the following calculation.
The previous calculation result will not be recalled after en-
tering multiple instructions.
Time, Decimal and Sexagesimal Calculations
This calculator performs decimal-to-sexagesimal conversion
and sexagesimal-to-decimal conversion. In addition, the four
basic arithmetic operations and memory calculations can be
carried out using the sexagesimal system.
Notation for sexagesimal is as follows:
123.404080
degree second
minute
Note: When the calculation or conversion result is con-
verted, a residual may occur.
Constant Calculations
In the constant calculations, the addend becomes a con-
stant. Subtraction and division are performed in the same
manner. For multiplication, the multiplicand becomes a
constant.
Functions
Refer to the calculation examples of each function.
For most calculations using functions, enter numerical
values before pressing the function key.


Produkt Specifikationer

Mærke: Sharp
Kategori: kalkulator
Model: EL-501W

Har du brug for hjælp?

Hvis du har brug for hjælp til Sharp EL-501W stil et spørgsmål nedenfor, og andre brugere vil svare dig




kalkulator Sharp Manualer

Sharp

Sharp EL-W535B Manual

9 Oktober 2024
Sharp

Sharp EL-2196BL Manual

23 September 2024
Sharp

Sharp EL-125A Manual

22 September 2024
Sharp

Sharp EL-6061H Manual

19 September 2024
Sharp

Sharp EL-W535X Manual

8 September 2024
Sharp

Sharp EL-509W Manual

8 September 2024
Sharp

Sharp EL-1750V Manual

26 August 2024
Sharp

Sharp EL-520WG Manual

24 August 2024
Sharp

Sharp EL-334R Manual

14 August 2024
Sharp

Sharp EL-124A Manual

12 August 2024

kalkulator Manualer

Nyeste kalkulator Manualer