SIME MURELLE.HT Manual


Læs gratis den danske manual til SIME MURELLE.HT (92 sider) i kategorien Vandvarmer & kedel. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.1 stjerner ud af 2 anmeldelser. Har du et spørgsmål om SIME MURELLE.HT, eller vil du spørge andre brugere om produktet?

Side 1/92
Fonderie SIME S.p.A.
6330337B - 07/2025 - R12
C od.
USER, INSTALLATION AND SERVICING INSTRUCTIONS
MURELLE.HT
Condensing wall mounted boiler
EN
TRANSLATION OF THE ORIGINAL ITALIAN INSTRUCTIONS
Visit our website:
www.sime.it
It is compulsory to
read the instructions.
2
RANGE RATED CERTIFICATION
The maximum power, in heating mode, of
MURELLE.HT
boilers
can be adapted, during the installation, to the thermal needs
of the system by modifying the setting of PAR 19 in the
0 .. 100
range.
The setting of PAR 19 = 100 is the factory setting that allows
the boiler to deliver its maximum power in heating mode. It
can be reduced by modifying the setting of PAR 19 as shown in
the table appearing below.
Once the new setting of PAR 19 has been made, the reduced
maximum power value (kW) MUST MANDATORILY be applied
beside the boiler’s data plate. For checks and adjustments af-
ter the modification, refer to the new value for the maximum
power.
The useful nominal power levels used are those relative to the
operating conditions (80-60°C) (Pn min - Pn max).
Example for
MURELLE.HT 25
boiler:
default heating power range: 1,65 - 24,2 setting of PAR 19 = 100
“reduced” heating power range: 1,65 - 19,7 setting PAR 19 = 80
DESCRIPTION
MURELLE.HT
25 30 35
Setting of PAR 19
Min Max Min Max Min Max
A - Factory power range (heating) kW 1,65 24,2 1,93 29,1 2,33 33,9
100
B - Reduced power ranges for maximum
power reduction (heating)
kW 1,65 21,9 1,93 26,4 2,33 30,7
90
kW 1,65 19,7 1,93 23,7 2,33 27,6
80
kW 1,65 17,4 1,93 20,9 2,33 24,4
70
kW 1,65 15,2 1,93 18,2 2,33 21,3
60
kW 1,65 12,9 1,93 15,5 2,33 18,1
50
kW 1,65 10,7 1,93 12,8 2,33 15,0
40
Boiler technical data plate
m
CAUTION
The grey fields must be filled in by the installer.
Range Rated label
A
B
A
Factory power range
B
Reduced power range for maximum power reduction