StarTech.com IES1G52UPDIN Manual
StarTech.com
Ikke kategoriseret
IES1G52UPDIN
Læs nedenfor 📖 manual på dansk for StarTech.com IES1G52UPDIN (2 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 2 personer og blev bedømt med 5.0 stjerner i gennemsnit af 1.5 brugere
Side 1/2

Quick-Start Guide
To view manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support.
Manual Revision: June 10, 2020
5 Port Unmanaged Industrial-Grade Switch 10/100/1000 Mbps + 2 Open SFP & DIN Input
Product Diagram (IES1G52UPDIN)
Front View
Side View
Component Function
1
Power (PW) LED
Indicators
• Color - Green
• DIN P3 (top), Terminal P2 (middle), Terminal P1
(bottom)
• On - is connectedPW1/2/3
• O - is not connectedPW1/2/3
2RLY LED Indicator
• Color - Amber
• On - shortAlarm Relay
• O - openAlarm Relay
3
F5/6 Port LED
Indicators
• Color - Green
• F5 (top), F6 (bottom)
• On - link/connection is detectedSFP
• O - link/connection is not detectedSFP
• Flashing - is activeSFP
9
10 11
4PoE Ports
• Connect any to provide an Network Device Ethernet
Connection Network Devices to up to 4
• Provide a ( to 4 Power over Ethernet PoE) Connection
Devices
• Maximum power budget is 30W per port up to a PoE
total overall power budget of 126W
5
SFP Slots F6 (Left) and
F5 (Right)
• Supports 100/1000Base-X SFP Transceiver Modules
6DIP Switches • Enable or SFP Slot F5 T5 Network Port
7Non-PoE Port
• Provide an to one Ethernet Connection Network
Device
• Connect using a or Fiber Copper Network Cable
8
PoE Port LED
Indicators
• Indicates the link and statusPoE Powered Device (PD)
LNK(Green)
• On - Network connection detected
• O - Network connection not detected
PoE (Amber)
• On - is detectedPoE PD
• O - is not detectedPoE PD
9DIN Power Port • Connect a DIN Connector Terminated Power Supply
10
Terminal Block Power
Input Port
• Provides power to the PoE Ports
• Supported power input voltage range is 48-56V
11 Grounding Screw
• Attach a to protect Grounding Wire Network
Equipment
Requirements
For the latest requirements, please visit .www.startech.com/IES1G52UPDIN
• DC Power Supply x (up to) 2
• (Optional) DIN Connector Terminated Power Supply x 1
• PoE Powered Device x (up to) 4
• RJ45 Terminated UTP/STP Cat 5e (or better) Network Cable x (up to) 5
• MSA-Compliant 100/1000Base-X SFP Transceiver Module x (up to) 2
• Fiber Cable x (up to) 2
• Earth Ground Connection x 1
4
1
5 6
32
7 8

FCC Compliance Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modications not expressly approved by StarTech.com could void the user’s authority to operate the equipment.
Industry Canada Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe [A] est conforme à la norme NMB-003 du Canada.
CAN ICES-3 (A)/NMB-3(A)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may
cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d’en compromettre le fonctionnement.
Use of Trademarks, Registered Trademarks, and other Protected Names and Symbols
This manual may make reference to trademarks, registered trademarks, and other protected names and/or symbols of third-
party companies not related in any way to StarTech.com. Where they occur these references are for illustrative purposes only
and do not represent an endorsement of a product or service by StarTech.com, or an endorsement of the product(s) to which
this manual applies by the third-party company in question. StarTech.com hereby acknowledges that all trademarks, registered
trademarks, service marks, and other protected names and/or symbols contained in this manual and related documents are the
property of their respective holders.
PHILLIPS® is a registered trademark of Phillips Screw Company in the United States or other countries.
Warranty Information
This product is backed by a two-year warranty.
For further information on product warranty terms and conditions, please refer to .www.startech.com/warranty
Limitation of Liability
In no event shall the liability of StarTech.com Ltd. and StarTech.com USA LLP (or their ocers, directors, employees or
agents) for any damages (whether direct or indirect, special, punitive, incidental, consequential, or otherwise), loss of prots,
loss of business, or any pecuniary loss, arising out of or related to the use of the product exceed the actual price paid for the
product. Some states do not allow the exclusion or limitation of incidental or consequential damages. If such laws apply, the
limitations or exclusions contained in this statement may not apply to you.
Safety Measures
• If product has an exposed circuit board, do not touch the product under power.
Mesures de sécurité
• Si l’un des circuits imprimés du produit est visible, ne pas touchez le produit lorsqu’il est sous tension.
安全対策
• 製品に露出した状態の回路基盤が含まれる場合、電源が入っている状態で製品に触らないでください。
Misure di sicurezza
• Se il prodotto p2-ha un circuito stampato visibile, non toccare il prodotto quando è acceso.
Säkerhetsåtgärder
• Rör aldrig vid enheter med oskyddade kretskort när strömmen är påslagen.
FR: startech.com/fr
DE: startech.com/de
ES: startech.com/es
NL: startech.com/nl
IT: startech.com/it
JP: startech.com/jp
StarTech.com Ltd.
45 Artisans Cres
London, Ontario
N5V 5E9
Canada
StarTech.com Ltd.
Unit B, Pinnacle 15
Gowerton Rd,
Brackmills
Northampton
NN4 7BW
United Kingdom
StarTech.com LLP
2500 Creekside
Parkwy
Lockbourne, Ohio
43137
U.S.A.
• Grounding Wire x 1
• (Optional - for power) Flat Head Screwdriver x 1
• (Optional - for mounting) #2 Phillips Head Screwdriver x 1
• (Optional - for mounting) Screws for Wall Mounting x 2
Installation
Grounding the Switch
Connect a to the on the and to the Grounding Wire Grounding Point Switch Earth
Ground Connection.
Connect the Redundant Power Sources
Terminal Block
Connecting and installing the Terminal Block must be completed by a licensed
Electrician.
Notes: Make sure that you turn o the power source before connecting the power wire
to the Terminal Block.
Do not exceed the recommend voltage as it may result in personal or product damage.
This unit includes an additional . When two 24V@1A Relay Circuit Terminal Power
Sources Relay Open Mode Power Source are connected the stays in . If only one is
connects the switches to . Relay Short Mode
1. Connect the from a or the provided Power Wires DC Power Source (48 - 56V DC)
Barrel Power Connector Adapter Terminal Block Connectors Switchto the on the .
The terminals are marked on the exterior of the (connect the to Switch Positive Wire
V+ Negative Wire V- and the to ).
• Secure the by tightening the in the with a Wires Screws Terminal Block Flat
Head Screwdriver
2. (Optional) Repeat step 1 to add a redundant . Power Source
DIN Power
Connect a to an available DIN Connector Terminated Power Supply Power Source
and to the DIN Power Port Switchon the .
Power Pinout Diagram
Select the Default Function and Speed using the DIP Switches
Toggle the up and/or down to select the DIP Switches SFP Slot F5 (Right) or T5
Network Port Network Speed and the .
Note: If DIP 1 is set to T5 then DIP 2 must be set to 1000M.
Produkt Specifikationer
Mærke: | StarTech.com |
Kategori: | Ikke kategoriseret |
Model: | IES1G52UPDIN |
Kode for international beskyttelse (IP): | IP30 |
Bredde: | 105 mm |
Dybde: | 142 mm |
Højde: | 36.2 mm |
Vægt: | 492 g |
Produktfarve: | Sort |
Pakkevægt: | 737 g |
Pakkedybde: | 162 mm |
Pakkebredde: | 211 mm |
Pakkehøjde: | 64 mm |
Opbevaringstemperatur (T-T): | -40 - 85 °C |
Relativ luftfugtighed ved drift (H-H): | 5 - 95 % |
Driftstemperatur (T-T): | -40 - 75 °C |
Husmateriale: | Stål |
Hurtig start guide: | Ja |
Certificering: | CE, RoHS, FCC, UL |
Strømforbrug (maks.): | 126 W |
Netværksstandarder: | IEEE 802.3, IEEE 802.3ab, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z |
Understøttede netværksprotokoller: | CSMA/CD |
LED-indikatorer: | Link, PoE, Power |
Kan monteres på væggen: | Ja |
Harmoniseret systemkode (HS): | 85176990 |
Hovedkassen højde (udvendigt): | 225 mm |
Hovedkassens længde (udvendigt): | 345 mm |
Hovedkassens bredde (udvendigt): | 355 mm |
DC indgangsspænding: | 48 - 56 V |
Produkter pr. hovedkasse (udvendigt): | 10 stk |
Fuld duplex: | Ja |
Strøm over Ethernet (PoE): | Ja |
Gennemsnitstid mellem fejl (MTBF): | 525058 t |
Switch-type: | Ikke administreret |
Total Power over Ethernet (PoE): | 120 W |
Power over Ethernet plus (PoE+) porte, antal: | 4 |
Power over Ethernet (PoE) effekt pr. port: | 30 W |
10G understøttelse: | Ingen |
Auto MDI/MDI-X: | Ja |
Flowkontrol support: | Ja |
Kobber ethernet kabelteknologi: | 10BASE-T, 10BASE-TX, 1000BASE-T, 1000BASE-TX |
Basis omskiftning RJ-45 Ethernet porte, antal: | 5 |
Basis omskiftning RJ-45 Ethernet porttype: | Gigabit Ethernet (10/100/1000) |
MAC adresselabel: | - entries |
Switch kapacitet: | 12 Gbit/sek. |
Jumbo Frames support: | Ja |
Jumbo rammer: | 9000 |
Stativ-montering: | Ingen |
Antal SFP modulslots: | 2 |
Sikkerhed: | EN60950-1, MET (UL) 60950-1 |
DIN-skinne montering: | Ja |
Auto-forhandling: | Ja |
Pakke bufferlager: | 1 MB |
Klemrække port: | Ja |
Klemrække inkluderet: | Ja |
Overspændingsbeskyttelse: | 2 kV |
Beskyttelse ved overspænding: | Ja |
Har du brug for hjælp?
Hvis du har brug for hjælp til StarTech.com IES1G52UPDIN stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret StarTech.com Manualer

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025
Ikke kategoriseret Manualer
- Ikke kategoriseret Coline
- Ikke kategoriseret EVE
- Ikke kategoriseret Swissvoice
- Ikke kategoriseret Leynew
- Ikke kategoriseret Teesa
- Ikke kategoriseret Renegade
- Ikke kategoriseret Girmi
- Ikke kategoriseret PATLITE
- Ikke kategoriseret Skymaster
- Ikke kategoriseret Cherub
- Ikke kategoriseret Carmen
- Ikke kategoriseret Naxa
- Ikke kategoriseret Kelvinator
- Ikke kategoriseret IXS
- Ikke kategoriseret Lasko
Nyeste Ikke kategoriseret Manualer

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025

7 Juni 2025