StarTech.com RK619WALL Manual


Læs gratis den danske manual til StarTech.com RK619WALL (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 25 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 13 anmeldelser. Har du et spørgsmål om StarTech.com RK619WALL, eller vil du spørge andre brugere om produktet?

Side 1/4
Quick-Start Guide
Manual Revision: August 29, 2023 9:24 AM
To view manuals, FAQs, videos, drivers, downloads, technical drawings, and more, visit www.startech.com/support
Product ID
RK619WALL
Product Diagram
Front - Angled View
Rear - Angled View
6U 19in Wall Mount Server Rack Cabinet
Component Function
1Window Area Enables monitoring of the at Mounted Equipment
a glance
2Door Lock Locks the using the included Door Keys
3Top and Bottom Vents Vented panel to promote airow
4Cooling Fan Top-mounted helps to regulate the 120mm Fan
temperature of the Mounted Equipment
5Cable Routing Holes Removable pre-installed cover. Enables convenient
passage for cables
6Wall-Mounting Holes
Used to fasten the onto a wallWall-Mounted Rack
Horizontal distance between the Wall-Mounting
Holes is 16 in (40.6 cm)
7Secondary Fan Hole Removable pre-installed cover. Enables installation
of (not included)120mm Fan
8Mounting Posts For mounting 19in Rack Equipment
Product Information
For the latest manuals, product information, technical specications, and declarations of
conformance, please visit: www.StarTech.com/RK619WALL
Requirements
Phillips Head Screwdriver
Mounting Hardware (not included)
Spirit/Bubble Level
(Optional) Wrench
(Optional) Cage Nut Tool
How to Identify the LOT Code Revision Number
The Revision Number (Rev #) appears as the fth and sixth digits of the LOT code,
located on the sticker axed to the product and its packaging. If the LOT code sticker
is missing, the product is Rev 01.
1
*Product may vary from image
4
5
2
3
8
7
6
5
3
4. Insert the (x 4) through the (x 4) on the M5 Screws Mounting Holes Rack
Equipment M5 Cage Nuts M5 Screw , and into the (x 4). Tighten each (x 4) using a
Phillips Head Screwdriver Rack Equipment Mounting Posts to fasten the to the .
Reverse the Door
To accommodate dierent rack congurations, you can reverse the door to open to the
left or right of the rack. The door uses spring-loaded pins located at the top and bottom
corners of the door.
1. While holding the , the in the of the Door Pull Pin Handle Down Inside Top Corner
Door Pull Top Corner Door Door Frame. the of the slightly away from the . (Figure 1)
Figure 1
2. In the of the of the , the and remove Bottom Corner Inside Door Pull Pin Handle Up
the . Retain the from the , for re-installation of the . Door Washer Bottom Corner Door
The may be located on the or the on the Washer Pin Lower Hinge Hole Door Frame
(Figure 2).
Figure 2
3. theRe-orientate Door so that the are located on the , with the Pins Opposite Side
Front Door Facing Outwards of the . (Figure 3)
Warnings!
Read the entire manual and ensure the instructions are fully understood before
assembling and/or using this product.
StarTech.com Ltd. is not responsible for any property damage and/or personal injury
resulting from the installation procedures outlined in this technical document.
Mounting hardware is not included with this product. Make sure to source
appropriate mounting hardware that is capable of supporting the weight of a loaded
Rack, and is adequate for the wall type the rack is going to be mounted on.
If you lack the necessary expertise required to attach this product to the wall structure
or to assess the suitability of the hardware provided, please contact a professional
installer.
Before adding equipment to this product, ensure this product has been properly mounted.
Never operate this product if parts are missing or damaged.
Ensure the weight of the equipment does not exceed the weight capacity of this product.
If the weight capacity is exceeded, personal injury or damage to the equipment are
possibilities. This product can support the following weight: up to 110.2lbs (50kg).
Wall structures vary. Ensure the type of wall structure and mounting hardware will
properly support the mounted equipment. Failure to do so might result in personal injury
and/or equipment damage. The wall structure should be capable of supporting at least
four times the weight of the mounted equipment.
Package Contents
6U Equipment Rack x 1
Set of Keys x 1
M5 Screws x 20
M5 Cage Nuts x 20
Installation
Mount the 6U Equipment Rack to a Mounting Surface
1. Place the against the Mounting Surface, in the location it will be 6U Equipment Rack
mounted (ensure it is level, using a ).Spirit/Bubble Level
2. Use the (x4), located on the as a Wall-Moutning Holes Wall Mount Server Rack
template, and mark the surface in all four locations where the mounting hardware
will be installed.
3. Use the appropriate to fasten the to Mounting Hardware Wall Mount Server Rack
the Mounting Surface.
Install the Cage Nuts
1. Install the into the on the . If M5 Cage Nuts Mounting Holes Mounting Posts
available, use a or your preferred installation method to install the Cage Nut Tool
Cage Nuts.
2. Repeat as many times as needed to install the number of Step 1 M5 Cage Nuts
required for the application.
3. Align the on the with the installed Mounting Holes Rack Equipment M5 Cage Nuts
on the .Mounting Posts


Produkt Specifikationer

Mærke: StarTech.com
Kategori: Ikke kategoriseret
Model: RK619WALL
Type: Vægmonteret stativ
Vekselstrømsindgangsspænding: 115 V
Bredde: 561 mm
Dybde: 398 mm
Højde: 332 mm
Vægt: 10500 g
Produktfarve: Sort
Pakkevægt: 13800 g
Pakkedybde: 450 mm
Pakkebredde: 465 mm
Pakkehøjde: 675 mm
Materiale: Stål
Certificering: RoHS, CE, UL, TAA
Harmoniseret systemkode (HS): 85381000
Monteringssæt: Ja
Produktdesign: 2-stolper
Antal blæsere: 1 blæser(e)
Maksimal vægtkapacitet: 50 kg
Overholdelse af branchestandarder: EIA-310-D
Rammetype: Lukket
Skruer inkluderet: Ja
Ventilator diameter: 120 mm
Kølingstype: Aktiv
Indre bredde: 550 mm
Forbedret kabelstyring: Ingen
Rackkapacitet: 6U
Montage hul form: Firkant
Indvendig dybde: 377 mm
Indre højde: 304.8 mm
Montering - dybde (maks): 286 mm
Antal skruer: 20
Nøglelås: Ja
Aftagelig hoveddør: Ja
Møtrikker inkluderet: Ja
Dørkonstruktion: Stål
Dørlås til hoveddøren: Ja
Sidepanel nøglelås: Ingen
Justerbare monteringsskinner: Ingen
Antal møtrikker: 20

Har du brug for hjælp?

Hvis du har brug for hjælp til StarTech.com RK619WALL stil et spørgsmål nedenfor, og andre brugere vil svare dig