Læs gratis den danske manual til Tripp Lite PDU3V20D354A (68 sider) i kategorien Strømskinne. Denne vejledning er vurderet som hjælpsom af 45 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 23 anmeldelser. Har du et spørgsmål om Tripp Lite PDU3V20D354A, eller vil du spørge andre brugere om produktet?

Side 1/68
1. Important Safety 2
Instructions
2. Installation 3
2.1 Mounting the ATS 3
2.2 Mounting the Power Strip 4
2.3 Connecting the Power Strip 4
to the ATS
2.4 Connecting the ATS 5
2.5 Networking the ATS 5
3. Features 6
4. Digital Display 8
5. Using the Digital Display 11
5.1 Navigating Display Menus 11
and Submenus
5.2 Navigating Config Menus 18
and Submenus
6 20. Configuration and Operation
6.1 Automatic Transfer Switch 20
7. Service 22
8. Warranty and Product 22
Registration
Español 24
Français 47
1
Owner’s Manual
PDU330AT6L15, PDU330AT6L21
(Series Number: AG-00D5)
3-Phase 1U Monitored Rack PDU
with Automatic Transfer Switch (ATS)
PDU3VD351
(Series Number: AG-00C2)
PDU3V20D354, PDU3V20D354A, PDU3V20D354B
(Series Number: AG-013C)
3-Phase Vertical Power Strip
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2015 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $50 value!
www.tripplite.com/warranty
15-05-226-933363.indb 1 6/29/2015 9:07:59 AM
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation, and storage of this product.
Failure to heed these instructions and warnings may affect the
product warranty.
The Power Strip provides the convenience of multiple outlets, but DOES NOT provide surge or
line noise protection for connected equipment.
Do not exceed the following equipment ratings:
Maximum full balanced load is 13.9A per bank when powered by a 3Φ ATS (Automatic
Transfer Switch) with a rated input of 24A.
Maximum full balanced load is 20A per bank when powered by a 3Φ ATS (Automatic Transfer
Switch) with a rated input of 35A.
The Automatic Transfer Switch and Power Strip are designed for indoor use only, in a controlled
environment, away from excess moisture, temperature extremes, conductive contaminants, dust
or direct sunlight.
Keep indoor ambient temperature between 32°F and 104°F (0°C and 40°C).
The Automatic Transfer Switch and Power Strip must be installed by a qualified technician only.
Do not attempt to mount the Automatic Transfer Switch or Power Strip to an insecure or
unstable surface.
Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
Connect the Automatic Transfer Switch to an outlet that is in accordance with your local building
codes and that is adequately protected against excess currents, short circuits and earth faults.
The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
Do not connect the Automatic Transfer Switch to an ungrounded outlet or to extension cords or
adapters that eliminate the connection to ground.
Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
Never attempt to install electrical equipment during a thunderstorm.
Individual equipment connected to the Power Strip should not draw more current than the
individual outlets rating.
The total load connected to the Power Strip must not exceed the maximum load rating for the
Automatic Transfer Switch.
Do not attempt to modify the Automatic Transfer Switch’s or Power Strip’s input plugs or power
cables.
Do not drill into or attempt to open any part of the Automatic Transfer Switch or Power Strip
housing. There are no user-serviceable parts inside.
Do not attempt to use the Automatic Transfer Switch or Power Strip if any part of it becomes
damaged.
Use of this equipment in life support applications where failure of this equipment can reasonably
be expected to cause the failure of the life support equipment or to significantly affect its safety
or effectiveness is not recommended. Do not use this equipment in the presence of a
flammable anesthetic mixture with air, oxygen or nitrous oxide.
1. Important Safety Instructions