Viking VMOR506SS Manual


Læs gratis den danske manual til Viking VMOR506SS (28 sider) i kategorien Mikrobølgeovn. Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 18 anmeldelser. Har du et spørgsmål om Viking VMOR506SS, eller vil du spørge andre brugere om produktet?

Side 1/28
Installation Guide
Convection Microwave Hood
VMOR506
E1
Mounting Space
This Convection Microwave Hood requires a mounting
space on a wall as shown in figure 1. It is designed to
be used with standard 12-inch wall cabinets.
For proper installation and servicing, a 2-inch space is
necessary between the top of the range backguard and
the bottom of the Convection Microwave Hood.
Wall Construction
This Convection Microwave Hood should be mounted
against and supported by a flat vertical wall. The wall
must be flat for proper installation. If the wall is not flat,
use spacers to fill in the gaps. Wall construction should
be a minimum of 2" x 4" wood studding and 3/8" or more
thick dry wall or plaster/lath. The mounting surfaces must
be capable of supporting a weight of 110 poundsthe
oven and contentsAND the weight of all items which
would normally be stored in the top cabinet above the
unit.
The unit should be attached to a minimum of one 2" x
4" wall stud or two 2" x 3" wall studs.
To find the location of the studs, one of the following
methods may be used:
Use a stud finder, a magnetic device which locates the
nails in the stud.
Use a hammer to tap lightly across the mounting
surface to find a solid sound. This will indicate stud
location.
The center of the stud can be located by probing the
wall with a small nail to find the edges of the stud and
then placing a mark halfway between the edges. The
center of any adjacent studs will normally be 16" or 24"
to either side of this mark.
IMPORTANTPlease Read and Follow!
Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are
recommended to install this product.
If a new electrical outlet is required, its installation should be completed by a qualified electrician before
the Convection Microwave Hood is installed. See ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
Backguard
At least 2"
15.5"
30"
12"
36" or more
from cooking
surface
72" or more
from floor
1


Produkt Specifikationer

Mærke: Viking
Kategori: Mikrobølgeovn
Model: VMOR506SS

Har du brug for hjælp?

Hvis du har brug for hjælp til Viking VMOR506SS stil et spørgsmål nedenfor, og andre brugere vil svare dig




Mikrobølgeovn Viking Manualer

Viking

Viking VMDD5306SS Manual

16 Januar 2024
Viking

Viking VMOS501SS Manual

12 November 2023
Viking

Viking RVMTK330SS Manual

15 Februar 2023
Viking

Viking CVMOS201 Manual

10 Februar 2023
Viking

Viking RVM320SS Manual

9 Januar 2023
Viking

Viking PMF302TKSS Manual

18 December 2022
Viking

Viking VMOR506SS Manual

1 December 2022
Viking

Viking VMOS201 Manual

30 November 2022
Viking

Viking RVMHC330SS Manual

28 Oktober 2022

Mikrobølgeovn Manualer

Nyeste Mikrobølgeovn Manualer