240W Single Output Switching Power Supply
HLG- 240 H series
SPECIFICATION
MODEL
HLG-240H-24
HLG-240H-54
OUTPUT
DC VOLTAGE
24V
54V
CONSTANT CURRENT REGION
Note.4
12 ~ 24V
27 ~ 54V
RATED CURRENT
10A
4.45A
RATED POWER
240W
240.3W
RIPPLE & NOISE (max.) Note.2
150mVp-p
350mVp-p
VOLTAGE ADJ. RANGE Note.6
22.4 ~ 25.6V
50 ~ 57V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometerA type and C type only
5 ~ 10A
2.23 ~ 4.45A
VOLTAGE TOLERANCE Note.3
±1.0%
±1.0%
LINE REGULATION
±0.5%
±0.5%
LOAD REGULATION
Note.8
±0.5%
±0.5%
SETUP, RISE TIME
Note.9
1000ms,80ms/115VAC 500ms,80ms/230VAC at full load
HOLD UP TIME (Typ.)
15ms at full load 230VAC /115VAC
INPUT
VOLTAGE RANGE
Note.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input
EFFICIENCY (Typ.)
92.5%
93.5%
AC CURRENT (Typ.)
4A / 115VAC / 230VAC 1.2A / 277VAC2A
INRUSH CURRENT (Typ.)
COLD
START
75A(t
width
=570
μ
s
measured
at
50%
I
peak
)
at
230VAC
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
PROTECTION
OVER CURRENT
Note.4
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
27 ~ 34V
60 ~ 67V
OVER VOLTAGE
Protection type : Shut down and latch off o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
WORKING TEMP.
-40 ~ +70 (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
TEMP. COEFFICIENT
± 0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY &
EMC
SAFETY STANDARDS Note.7
UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750, CSA C22.2 No. 250.0-08, TUV EN61347-1, EN61347-2-13 independent
(except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67, J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC EMISSION
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria B
OTHERS
MTBF
207.9K hrs min. MIL- -217F (25 )HDBK
DIMENSION
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H-C)
PACKING
1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
NOTE
Fil
e
N am e: H L G- -S PE2 40 H
C
2017-
11
IP65 IP67
Baua rt ge pr uft
Sic h erhe it
egelm a ge
od o s
be wac g
www. tuv.c om
ID 200 00 00 000
HLG- -240H 24
HLG- -240H 54


Produkt Specifikationer

Mærke: Vivotek
Kategori: Ikke kategoriseret
Model: HLG-240H

Har du brug for hjælp?

Hvis du har brug for hjælp til Vivotek HLG-240H stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Vivotek Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer