Læs gratis den danske manual til Advantech AMAX-4817 (4 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 3.6 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Advantech AMAX-4817, eller vil du spørge andre brugere om produktet?

Side 1/4
AMAX-4817/4820 Startup Manual 1
Before installation, please check that the following items are
included in the shipment:
1. AMAX-4817/4820 module
2. Terminal blocks (see Specications for more details)
3. Startup Manual
If any of these items are missing or damaged, contact your
distributor or sales representative immediately.
For more detailed information about this product, download
The AMAX-4817/4820 ESI le can be downloaded from
the Advantech website at http://www.advantech.com.
Every EtherCAT SubDevice information (ESI) le con-
tains the conguration data of an EtherCAT SubDevice
module. Various EtherCAT communication settings can
be dened from the ESI les of connected SubDevice
units as well as the network connection information. ESI
les are saved to the conguration tool to provide net-
work conguration data. Subsequently, the network
conguration data can be downloaded to the EtherCAT
MainDevice unit for conguring an EtherCAT network.
AMAX-4817/4820
Industrial EtherCAT SubDevice Modules
Startup Manual
The AMAX-4817/4820 series comprises industrial EtherCAT
SubDevice modules equipped with the EtherCAT protocol.
The modules compact size and integrated DIN-rail mount
kit ensure easy installation in cabinets. The modules also
feature euro-type pluggable terminal blocks and LED in-
dicators that facilitate system setup and maintenance. All
modules are equipped with an isolation circuit that ensures
current protection for demanding industrial applications.
General
• Connectors
- N x 10-pin terminal block (3.81 mm)
(AMAX-4817 N = 2, AMAX-4820 N = 1)
- 2 x 3-pin screw terminal blocks (3.81 mm)
- 2 x RJ-45 (EtherCAT)
• Dimensions:120 x 120 x 40 mm
3
• OperatingTemperature: -20 ~ 60 °C (32 ~ 140 °F)
• StorageTemperature:-40 ~ 70 °C (-40 ~ 158 °F)
• StorageHumidity:5 ~ 95% RH (non-condensing)
• PowerSupply:10 ~ 30 V
DC
Communications
• Interface:EtherCAT
• DataTransferMedium:Ethernet/EtherCAT cable (CAT5
min.), shielded
• DistanceBetweenModules:100 m max. (100BASE-TX)
• CommunicationCycleTime100 μs
• DataTransferRates:100 Mbps
• Conguration:Not required
AnalogInput(AMAX-4817)
• Channels: 8 channels
• Resolution: 16-bit
• InputVoltageRange:0 ~ 10 V, ±10 V, 0~20 mA, ±20 mA
• Common-ModeInputVoltageRange:±275 V
• MeasuringError: < ±0.1%
• IsolationProtection: 2,500 V
DC
• Bandwidth(-3dB):1.375 kHz/ch
PackingList
For more information on this and other Advantech
products, please visit our website at:
http://www.advantech.com
http://www.advantech.com/eplatform
For technical support and service, please visit our
support website at:
http://support.advantech.com
This manual is for the AMAX-4817 and 4820 modules.
Part No. 2001481702
Printed in China
Edition 3
May 2023
Specications
Overview
UserManual
EtherCATSubDeviceInformationFile


Produkt Specifikationer

Mærke: Advantech
Kategori: Ikke kategoriseret
Model: AMAX-4817

Har du brug for hjælp?

Hvis du har brug for hjælp til Advantech AMAX-4817 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Advantech Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer