Ashland UT56 Manual


Læs gratis den danske manual til Ashland UT56 (18 sider) i kategorien Vandpumpe. Denne vejledning er vurderet som hjælpsom af 26 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 13.5 anmeldelser. Har du et spørgsmål om Ashland UT56, eller vil du spørge andre brugere om produktet?

Side 1/18
• Thankyouforpurchasingthispump.Takethetimeto
 readtheinstructionscarefullybeforeusingthis
 product.Westronglyrecommendthatyoukeepthis
 instructionmanualinasafeplaceforfuturereference.
• PleaserefertoourwebsiteandtheProductsCenterfor
 additionalinstallationandoperationinstructions.
• Refertothewebsiteforreplacementpartsinformation.
Danger indicates an
imminent hazardous situation
which, if not avoided, WILL result in death or
serious injury.
Caution indicates a
potentially hazardous situation
which, if not avoided, MAY result in minor or
moderate injury.
OPERATION,PERFORMANCE,
ANDSPECIFICATIONS
Submersible
Utility Pump
MARKS AND MEANING:
LIMITED WARRANTY
Thispumpiswarrantedtobefreefromdefectsinmaterialandworkmanship
andtoperformwithinapplicablespecicationsforaperiodofoneyearfrom
dateofinstallationor18monthsfromdateofmanufacture,whichevercomes
rst.Obligationunderthiswarrantyislimitedtorepairingorreplacinganypart
thereof,whichshallwithinoneyearbereturnedtouswithtransportationcharges
prepaid,andprovedtobedefective.
Theabovelimitedwarrantytakestheplaceofallotherwarranties,expressor
impliedandcorrectionofsuchdefectsbyreplacementorrepairshallconstitute
afulllmentofallobligationsunderthetermsofthewarranty,whichspecically
EXCLUDESanyincidentaldamagescausedbyorassociatedwiththisproductor
itsuse.Thewarrantydoesnotcoveranyunitwhichhasbeendamagedeitherin
transitorbymisuse,accidentornegligence.Nowarrantyorrepresentativenot
containedhereinshallbebinding.
PERFORMANCE
    GPMatTotalFeetofHead  Max. 
 Model HP 0’ 5’ 10’ 15’ 20’ Head 
 
UT56 1/3 48 42 31 22 13 25’
UT80 1/2 52 45 36 27 16 27’ 
ModelUT56/80
WARNING
CAUTION
DANGER
Warning” indicates an
imminent hazardous situation
which, if not avoided, MAY result in death or
serious injury.
1
DANGER
Beforeinstallation,readthefollowinginstructionscare-
fully.Failuretofollowinstructionandsafetyinformation
couldcauseseriousbodilyinjury,deathand/orproperty
damage.EachAshlandPumpisindividuallyfactorytested
toensureproperperformance.Closelyfollowingthese
instructionswilleliminatepotentialoperatingproblems
assuringyearsoftrouble-freeservice.
Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for
losses, injury or death resulting from failure to observe
these safety precautions, misuse, abuse or misapplica-
tion of pumps or equipment.
All returned products must
be cleaned, sanitized, or
decontaminated prior to shipment, to
ensure employees will not be exposed to
health hazards in handling said materials.
All applicable laws and regulations shall apply.
Bronze/brassfittedpumpsmay 
  containleadlevelshigherthancon-
sideredsafeforpotablewatersystems.Government
agencieshavedeterminedthatleadedcopperalloys
shouldnotbeusedinpotablewaterapplications.
  Installation,wiring,andjunction
connectionsmustbeinaccord- 
ancewiththeNationalElectricCodeandallapplicable
stateandlocalcodes.Requirementsmayvarydepend-
ingonusageandlocation.
  Installationandservicingistobe
  conductedbyqualiedpersonnelonly.
Rotating machinery. Amputation
or severe lacerations can
result. Keep clear of suction and
discharge openings. DO NOT insert
fingers into pump with power connected.
  Alwaysweareyeprotectionwhen
  workingonpumps.Donotwearloose
clothingthatmaybecomeentangledinmovingparts.
Pumpsbuildupheatand 
pressureduringoperation.
Allowtimeforpumpstocoolbeforehandlingorser-
vicing.
Hazardous Voltage can shock,
burn or cause death. Thispumpis
not intendedforuseinswimmingpoolsor
 waterinstallationswherehumancontactwith
 pumpedfluidispossible.
Riskofelectricalshock.To 
reduceriskofelectricalshock, 
 alwaysdisconnectpumpfrompowersource
 beforehandling. Lock out power & tag.
2
WARNING
 DoNotusethesepumpsinwater
 over145°F.Donotexceedmanu-
facturesrecommendedmaximumperformance,asthis
couldcausethemotortooverheat.
WARNING
WARNING
WARNING
WARNING
DANGER
DANGER
DANGER
ThesepumpsareNOTtobe 
installedinlocationsclassified 
ashazardousinaccordancewiththe 
 NationalElectricCode,ANSI/NFPA70.
WARNING
 Utilitypumpsoftenhandlematerials
 whichcouldcauseillnessordisease.
Wearadequateprotectiveclothingwhenworkingona
usedpumporpiping.Neverenterabasinafterithas
beenused.
WARNING
 Donotintroduceintoanysewer,
 eitherdirectly,orthroughakitchen
wastedisposalunitortoilet:SeafoodShells,Aquarium
Gravel,CatLitter,PlasticObjects,SanitaryNapkinsor
Tampons,Diapers,Rags,DisposableWipesorCloth,
Medications,FlammableMaterial,OilorGrease,
StrongChemicals,Gasoline.
DANGER
DANGER
  Donotlift,carryorhangpumpby
theelectricalcables.Damageto 
 theelectricalcablescancauseshock,burnsor
 death.Neverhandleconnectedpowercords
 withwethands.Useappropriateliftingdevice.
DANGER
Failuretopermanentlygroundthe
  pump,motorandcontrolsbefore
 connectingtopowercancauseshock,burns
 ordeath.
DANGER
 Makesureliftinghandlesaresecurely
 fastenedeachtimebeforelifting.
CAUTION
• Operationagainstacloseddischargevalvewillcause
 prematurebearingandsealfailureonanypump.
• Anywiringofpumpsshouldbeperformedbya
 qualiedelectrician.
• Cableshouldbeprotectedatalltimestoavoid
 punctures,cuts,bruises,andabrasions-inspect
 frequently.
• Neverhandleconnectedpowercordswithwethands.
• Neverletcordsorplugslieinwateroutsidethesump
 pit.
Submersible Utility Pumps
Model: UT56 & UT80 Series
General Safety Information


Produkt Specifikationer

Mærke: Ashland
Kategori: Vandpumpe
Model: UT56

Har du brug for hjælp?

Hvis du har brug for hjælp til Ashland UT56 stil et spørgsmål nedenfor, og andre brugere vil svare dig