ASI TURBO-Pro 10-0196-1-41 Manual

ASI Ikke kategoriseret TURBO-Pro 10-0196-1-41

Læs gratis den danske manual til ASI TURBO-Pro 10-0196-1-41 (8 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 81 personer og har en gennemsnitlig bedømmelse på 4.9 stjerner ud af 41 anmeldelser. Har du et spørgsmål om ASI TURBO-Pro 10-0196-1-41, eller vil du spørge andre brugere om produktet?

Side 1/8
1
PLEASE CAREFULLY READ THROUGH THIS MANUAL BEFORE USING THE PRODUCT.
OBSERVING ALL SAFETY INFORMATION, WARNINGS AND CAUTIONS WILL PROTECT
YOURSELF AND OTHERS. PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE.
www.americanspecialties.com
AMERICAN SPECIALTIES, INC.
441 Saw Mill River Road, Yonkers, NY 10701 (914) 476-9000
MODEL # 0196-1
MODEL # 0196-2
MODEL # 0196-3
DIM’S
inch[mm]
ITEM CATEGORY
Operating Voltage, 0196-1
Operating Voltage, 0196-2
Operating Voltage, 0196-3
Output Warm Air Volume
Output Warm Air Temp
Output Air Speed
Sound Pressure
Motor Type
Motor Thermal Protection
Heater Element
Heater Thermal Protection
Drying Time
Standby Power
Circuit Operation
Sensor Range
Timing Protection
Timing Duration
Cover Type
Cover Finish
Net Weight
Shipping Weight
Unit Size
PERFORMANCE DATA
TECHNICAL SPECIFICATIONS
120 VAC, 50/60 Hz, 1.0 kW
240 VAC, 50/60 Hz, 1.0 kW
277 VAC, 60 Hz, 1.0 kW
32 - 42 CFM {55 - 72 m³/h}, Adjustable by Owner
131°F {55°C} at ambient T = 77°F {25°C}, MAX, Adjustable by Owner
208 mph (305 ft/s) [93 m/s {335 km/h}] - 257 mph (378 ft/s) [115 m/s {414 km/h}], Adjustable by Owner
68 to 73.8 dB-A @ 2m, Adjustable by Owner
0.67 HP, 16 - 29 krpm, Adjustable, Brush Type, Dual Ball Bearings
120 VAC, Auto Resetting Thermostat turns unit off at 203°F {95°C}
240 VAC, Auto Resetting Thermostat turns unit off at 203°F {95°C}
ON/ OFF Heating options; Range Adjustable by Owner, 325 - 500 W
Auto Resetting Thermostat turns heater element off at 185°F {85°C}, Resets at
167°F {75°C},Thermal cut-off at 288°F {142°C}
Less than 15 seconds
Less than 0.5W
Infrared Automatic, self adjusting
Standard 6-11/16" ± 25/32" [170 ± 20] , Adjustable, range 3-15/16" to 9-1/16" [100 to 230]
60 seconds auto shut off
2 seconds delayed turn off after last sensor read
18 gauge (.047" [1.2]) thick drawn steel or 304 series stainless steel
Powder coating white or matte black on steel or satin on stainless steel
9.3 lbs {4.2 kg}
10.4 lbs {4.7 kg}
8-5/8" W x 13-9/16" H x 4" D [219 x 345 x 101]
1705120000 Rev C 05 July 2018
Patented
8-5/8
[219]
4″
[101]
13-9/16″
[345]
Operating Instructions and Parts Manual
Hand Dryer Surface-mounted -compliant hand dr yer ADA
2www.americanspecialties.com
VAC
110
115
120
208
220
230
240
277
Motor Heater
Vac
110
115
120
208
220
230
240
240
Inrush A(W)
5.73 (630)
5.99 (689)
6.25 (750)
2.71 (563)
2.86 (630)
2.99 (689)
3.13 (750)
3.13 (750)
Operating A (W)
3.82 (420)
3.99 (459)
4.17 (500)
1.81 (376)
1.91 (420)
2.00 (459)
2.08 (500)
2.08 (500)
3.82 (420)
3.99 (459)
4.17 (500)
1.81 (376)
1.91 (420)
2.00 (459)
2.08 (500)
2.08 (500)
Vac
110
115
120
208
220
230
240
240
Total
Inrush A(W)
9.55 (1050)
9.98 (1148)
10.42 (1250)
4.51 (939)
4.77 (1050)
4.99 (1148)
5.21 (1250)
5.21 (1250)
Operating A(W)
7.64 (840)
7.99 (918)
8.33 (1000)
3.61 (751)
3.82 (840)
3.99 (918)
4.17 (1000)
4.17 (1000)
0196-1
0196-1
0196-1
0196-2
0196-2
0196-2
0196-2
0196-3
ModelInput
Operating A(W)
Installation
1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with
the current edition of the local wiring regulations code having jurisdiction. Installation should be
performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at knockout (KO) location.
For two or more dryers, dryers should be no closer than 24" [610] on center.Note:
3. Remove and retain two (2) Main cover screws and Main cover.
4. a. For in-wall (concealed) power supply - (See MT & IG 1705120001)
Provide supply wire to KO location according to local code and attach securely to chassis at KO
with appropriate strain relief connector (not supplied).
b. For Surface Mounted Conduit (exposed) power supply -
Provide appropriate conduit to entry location according to local code and attach securely to chassis
with correct strain relief connector (not supplied).
5. Drill four (4) holes at locations A, B, C and D of 5/16" Diameter x 1-3/8" deep [Ø8 x 35] if using
wall anchors (not supplied). Install anchors flush with wall face, or install other fastening
system suitable for wall conditions (not supplied). Attach dryer to wall. For wood wall/studs, use 1/4"
dia. (M6) screws at length that will ensure 1" [25] min. stud penetration. For masonry walls,
use expansion bolts or anchors (not supplied) for 1/4" dia (M6) screws to ensure penetration 1/4" [6]
deeper than anchor. Shim if necessary to ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to
terminal block where indicated and connect ground wire to base plate with ground screw.
Connections:
. Connect the live wire (colored Brown, Red or Black) to the terminal block marked "L".A
. Connect the neutral wire (colored Black, Blue, White or Grey) or connect the second live wireB
(colored Red or Orange) to the terminal block marked "N".
. Connect the ground wire to the terminal block marked " " or to the green screw marked " ".C
Bare grounding (earth) wires should be sleeved with green and yellow or green tubing.
Colors of live and neutral wires depend on voltage of supply service and requirements of Building
and Electrical Code having jurisdiction.
7. Replace cover and reinstall screws retained in Step 3 above. Do not over-tighten screws.
Installation Kit Included (find in carton)
Service Tool Included (with installation kit)
Security hex driver 4 mm x 1 pc (5/32" pin-hex will work if tool is lost)
Please unpack the unit and check the quantity of the above tool and kit.
1. Self-Threading screws 1/4" x 1-1/2" [M6 x 38] x 4 pcs 3. Nylon bushing x 4 pcs
2. Metal Washer 3/8" I.D. x 7/8" O.D. x 1/16" thick [Ø10 x Ø22 x 1.6] x 4 pcs
4. Crimp-on terminal wire tip x 3 pcs
Operating Instructions and Parts Manual
Hand Dryer Surf ace-mounted -com p li ant hand dr yer ADA
NOTE: All Dim’s Inch [mm]
1705120000 Rev C 05 July 2018