Avantco SS-PT-27-HC Manual
Læs gratis den danske manual til Avantco SS-PT-27-HC (16 sider) i kategorien Køleskab. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om Avantco SS-PT-27-HC, eller vil du spørge andre brugere om produktet?
Side 1/16

User Manual
www.AvantcoRefrigeration.com
04/2023
#178SSPT27HC
#178SSPT36HC
#178SSPT48HC
#178SSPT60HC
#178SSPT72HC
#178SSPT27MHC
#178SSPT36MHC
#178SSPT48MHC
#178SSPT60MHC
#178SSPT72MHC
#178SSPPT60GHC
#178SSPPT80GHC
#178SSPTM4812
#178SSPT488
#178SSPT6010
#178SSPT7112
#178SSPTM6015
#178SSPTM7118
Base Models:
SS Series Prep Tables
178SSPT48MHC
( Variations listed on page 3 )
Please read the manual thoroughly prior to equipment set-up, operation, and maintenance.
Note:

2
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Table of Contents
Model Variations ................................................................................................................. 3
Safety .................................................................................................................................... 4
Installation ............................................................................................................................ 5
Uncrating .............................................................................................................................. 5
Cabinet Location Guidelines ........................................................................................... 5
Electrical ............................................................................................................................... 6
Adjusting Temperature ..................................................................................................... 6
Defrost System ................................................................................................................... 7
Loading Food Pans ............................................................................................................ 7
Safety / Warning ................................................................................................................. 7
Operation / Maintenance ................................................................................................. 8
Condensor Coil Cleaning Instructions .......................................................................... 9
Layouts .................................................................................................................................. 10-13
Troubleshooting ................................................................................................................ 14-16
Please Read Handbook Before
using Equipment and Keep for Future use.
NOTICE – USE THIS APPLIANCE FOR ITS INTENDED PURPOSES AS DESCRIBED IN THIS USER MANUAL.
A PROPERLY MAINTAINED UNIT WILL GIVE YOU MANY YEARS OF TROUBLE FREE SERVICE.

3
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Base Model Left Middle Right
Corresponding Models
178SSPPT1
Drawer 178SSPPT1A
178SSPPT260
178SSPPT260
178SSPPT260
Slim Door
Slim Drawer
Slim Drawer
Drawer
Drawer
Door
178SSPPT260B
178SSPPT260C
178SSPPT260D
178SSPPT2
178SSPPT2
178SSPPT2
Door
Drawer
Drawer
Drawer
Drawer
Door
178SSPPT2B
178SSPPT2C
178SSPPT2D
178SSPPT3
178SSPPT3
178SSPPT3
178SSPPT3
178SSPPT3
178SSPPT3
178SSPPT3
Door
Door
Door
Drawer
Drawer
Drawer
Drawer
Door
Drawer
Drawer
Drawer
Door
Door
Drawer
Drawer
Door
Drawer
Drawer
Door
Drawer
Door
178SSPPT3E
178SSPPT3F
178SSPPT3G
178SSPPT3H
178SSPPT3I
178SSPPT3J
178SSPPT3K
Standard
Top
ADA
Height
Extended
Cutting
Board
Both
178SSPT27HC
178SSPT27A 178SSPT27C 178SSPT27AC
178SSPT36HC
178SSPT36A 178SSPT36C 178SSPT36AC
178SSPT48HC
178SSPT48A 178SSPT48C 178SSPT48AC
178SSPT60HC
178SSPT60A 178SSPT60C 178SSPT60AC
178SSPT72HC
178SSPT72A 178SSPT71C 178SSPT71AC
Mega
Top
ADA
Height
Extended
Cutting
Board
Both
178SSPT27MHC
178SSPT27MA 178SSPT27MC
178SSPT27MAC
178SSPT36MHC
178SSPT36MA 178SSPT36MC
178SSPT36MAC
178SSPT48MHC
178SSPT48MA 178SSPT48MC
178SSPT48MAC
178SSPT60MHC
178SSPT60MA 178SSPT60MC
178SSPT60MAC
178SSPT72MHC
178SSPT72MA 178SSPT71MC
178SSPT72MAC
Standard Kit with Refrigerated Topping Rail, Sneeze Guard
178SSPPT60GHC
178SSPPT60GK
178SSPPT80GHC
178SSPPT80GK
Standard Top
with workstation
ADA
Height
Extended
Cutting
Board
Both
--
-- -- --
--
-- -- --
178SSPT488
178SSPTA488 178SSPTC488 178SSPTAC488
178SSPT6010
178SSPTA6010 178SSPTC6010 178SSPTAC6010
178SSPT7112
178SSPTA7112 178SSPTC7112 178SSPTAC7112
Mega Top
with workstation
ADA
Height
Extended
Cutting
Board
Both
--
-- -- --
--
-- -- --
178SSPTM4812
178SSPTAM4812 178SSPTCM4812 178SSPTACM4812
178SSPTM6015
178SSPTAM6015 178SSPTCM6015 178SSPTACM6015
178SSPTM7118
178SSPTAM7118 178SSPTCM7118 178SSPTAC7118
Sandwich Prep Tables
Mega Top Prep Tables
Pizza Prep Tables
Granite Top Pizza Prep Tables

4
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Warning
DANGER – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY
TRAINED SERVICE PERSONNEL. DO NOT PUNCTURE REFRIGERANT TUBING.
PELIGRO – RRIESGO DE INCENDIO O EXPLOSION. REFRIGERANTE INFLAMABLE UTILIZADO. PARA
SER REPARADO SOLAMENTE POR PERSONAL DE SERVICIO CALIFICADO. NO PINCHAR LA TUBERÍA
REFRIGERANTE.
DANGER – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONFIER LES
RÉPARATIONS À UN TECHNICIEN SPÉCIALISÉ. NE PAS PERFORER LA TUBULURE CONTENANT LE
FRIGORIGENE.
CAUTION – RISK OF FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. CONSULT REPAIR MANUAL/
OWNER’S GUIDE BEFORE ATTEMPTING TO SERVICE THIS PRODUCT. ALL SAFETY PRECAUTIONS MUST BE
FOLLOWED.
ATENCION – RIESGO DE INCENDIO O EXPLOSIÓN. REFRIGERANTE INFLAMABLE UTILIZADO.
CONSULTE EL MANUAL DE REPARACIÓN / GUÍA DEL PROPIETARIO ANTES DE INTENTAR DAR SERVICIO A
ESTE PRODUCTO. DEBEN CUMPLIR CON TODAS LAS PRECAUCIONES DE SEGURIDAD.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION. LE FRIGORIGÈNE EST INFLAMMABLE. CONSULTER LE
MANUEL DU PROPRIÉTAIRE/GUIDE DE RÉPARATION AVANT DE TENTER UNE RÉPARATION. TOUTES LE
MESURES DE SÉCURITÉ DOIVENT ÊTRE RESPECTÉES.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO PUNCTURE OF REFRIGERANT TUBING; FOLLOW
HANDLING INSTRUCTIONS CAREFULLY. FLAMMABLE REFRIGERANT USED.
ATENCION – RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A LA PERFORACION DE LA TUBERÍA
REFRIGERANTE; SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO. REFRIGERANTE
INFLAMABLE UTILIZADO.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LA TUBULURE CONTENTANT LE FRIGORIGÈNE EST
PERFORÉE; SUIVRE LES INSTRUCTIONS DE MANUTENTION AVEC SOIN. LE FRIGORIGÈNE EST
INFLAMMABLE.
CAUTION – RISK OF FIRE OR EXPLOSION DUE TO FLAMMABLE REFRIGERANT USED.
FOLLOW HANDLING INSTRUCTIONS CAREFULLY IN COMPLIANCE WITH LOCAL GOVERNMENT
REGULATIONS.
ATENCION – RIESGO DE INCENDIO O EXPLOSIÓN DEBIDO A REFRIGERANTE INFLAMABLE UTILIZADO.
SIGA LAS INSTRUCCIONES DE MANIPULACIÓN CON CUIDADO CONFORME A LAS REGLAS DE LA
MUNICIPALIDAD.
ATTENTION – RISQUE DE FEU OU D’EXPLOSION SI LE FRIGORIGÈNE EST INFLAMMABLE. SUIVRE LES
INSTRUCTIONS DE MANUTENTION AVEC SOIN CONFORMÉMENT AUX RÈGLEMENTATION
GOUVERNEMENTALE LOCAUX.
Safety

5
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
This unit is intended for use in a temperature-controlled environment less than 75 degrees
Fahrenheit and 60% relative humidity. Malfunction due to improper conditions is not covered
under warranty.
IMPORTANT – Please Read Before Installation:
• If the shelf has a raised lip, the lip needs to be installed facing up towards the rear of the cabinet to
promote proper air flow. Failure to install the shelves properly is considered user error and is not
covered by warranty.
• If the unit has recently been transported on its side, please let the unit stand still for a minimum of
24 hours before plugging it in.
• Make sure that the unit has reached the desired temperature before loading the unit with products.
This unit is meant for keeping cold products cold, not chilling warm products.
• Make sure that there is proper ventilation around the unit in the area where it will operate.
• Make sure all accessories are installed (i.e., shelves, shelf clips, casters) before plugging the unit in.
• Do not attempt to remove or repair any component of the unit. Consult an authorized service
technician for servicing/repair.
• Do not hang on doors or stand inside the unit.
• Do not store flammable, explosive, or corrosive liquids or gas in or near the cooler.
• Please read through the manual in its entirety.
• This unit is designed to perform in a temperature-controlled environment at 60% relative humidity.
The unit should be located away from doors, air ducts, and fans that could disrupt airflow and
negatively impact performance.
Installation
Cabinet Location Guidelines
• Install the unit on strong and leveled surfaces.
- If the surface is uneven, the unit may be noisy.
- The unit may malfunction if the surface is uneven.
- Keep the cooler stable to avoid vibration and noise.
• Install the unit in an indoor, well-ventilated area.
- For best performance, please maintain clearance of 3” on the back of the unit.
- Do not use outdoors. For indoor use only.
- Avoid direct sunlight.
- Unit should be placed far from any heating source to avoid decrease of refrigeration eciency.
• Avoid installation in a high humidity and/or dusty area.
- Humidity above 60% can cause the unit to rust, to collect condensation, and may decrease eciency.
- Dust collected on condenser coil will cause unit to malfunction.
• Malfunction due to temperatures above 75 degrees Fahrenheit, humidity above 60%, or improperly
maintained condenser coil will void the warranty.

6
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
• Select a location away from heat and moisture-generating equipment.
- Ambient temperatures above 75 degrees Fahrenheit may cause the compressor to malfunction.
- Using this unit in consistent ambient temperatures above 75 degrees Fahrenheit will void the warranty.
Any exposure to ambient temperatures of 90 degrees Fahrenheit or above will also void the warranty.
- Do not install the unit inside a closet or alcove.
• For optimal performance, 3” of clearance is required around all louvered or vented panels, to allow for
proper air flow.
- Component failure due to improper installation is not covered under the warranty.
• Please ensure that the required voltage is being supplied at all times.
• The unit should be plugged into a grounded and properly-sized electrical outlet with appropriate
over-current projection. Please refer to the electrical requirements on the unit’s nameplate.
• This unit should have its own dedicated outlet.
• Do not use extention cords.
• Ensure the unit is not resting on or against the electrical cord.
• If the unit is not in use for a long period of time, please unplug the unit from the outlet.
• To avoid shock and fire hazards, do not plug in or unplug the unit with wet hands.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
Electrical
Digital Control Units
• Hold “SET” for 1 sec. The display will flash the current minimum temperature.
• Use the arrow buttons to adjust the minimum temperature you want it to run at.
• Press “SET” again to save your settings.
Always remember to calculate the dierential if you change the minimum temperature setting. The cabinet
temperature will fluctuate up to +7 degrees over your set minimum temperature as the compressor runs and
shuts o. Setting the temperature too high will result in unsafe maximum temperatures and possible health
code violations.
Your new refrigerator is already factory-set to run at
optimum temperatures for food safety and should
require no adjustments.
Refrigerators are set to cycle between a minimum temperature of 33 degrees Fahrenheit and a maximum
temperature of 40 degrees Fahrenheit.
Adjusting the temperature changes the minimum temperature your unit will run at. Your unit will not run
constantly at this setting. To change it, follow these instructions:
Adjusting Temperature
set
mute

7
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Pizza prep units and sandwich prep units are designed to function with all pans in place, even if some pans
are to be left empty. For maximum food freshness, fill the pans only with an amount that can be used in a
specific usage period. During non-use, please close the insulated lid cover.
Loading Food Pans
Defrost System:
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-o water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for
a pre-determined duration.
Please pay close attention to the safety notices in this section. Disregarding these notices may lead to seri-
ous injury and/or damage to the unit.
ATTENTION
• To minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for
your unit.
• Do not use extension cords.
• Do not put your hands under the unit while it is being moved.
• When the unit is not in use for a long period of time, please unplug the unit from the outlet.
• After unplugging the unit, wait at least 10 minutes before plugging it back in. Failure to do so could
cause damage to the compressor.
UNPLUG CORD
• To minimize shock and fire hazards, please do not plug or unplug the cord with wet hands.
• During maintenance and cleaning, please unplug the unit.
Safety / Warning
PROPER GROUNDING REQUIRED
To minimize shock and fire hazards, make sure that the unit is properly grounded.
WARNING
• Do not attempt to remove or repair any component unless instructed by factory.
• Make sure that the unit is not resting on or against the electrical cord and plug.
• To minimize personal injury, do not hang on the doors.
• Do not store any flammable and explosive gas or liquids inside the unit.
• Do not attempt to alter or tamper with the electrical cord.

8
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
WARNING
DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.
Loading Product
• Make sure there is at lease four inches of clearance from the evaporator.
• Ensure all shelves are sitting level and properly secured before loading products.
• Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Condenser Coil
• For ecient operation, keep the condenser surface free of dust, dirt, and lint.
• We recommend cleaning the condenser coil at least once per month.
Cleaning the Fan Blades and Motor
• If necessary, clean the fan blades and motor with a soft cloth.
• If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.
Cleaning the Interior of the Unit
• When cleaning the cabinet interior, use a solvent of warm water and mild soap.
• Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
• Wash door gaskets on a regular basis, preferably weekly. Simply remove the door gasket from the
frame of the door, soak in warm water and soap for thirty (30) minutes, dry it with a soft cloth, and
replace it.
• Check door gaskets for proper seal after they are replaced.
• Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm
water. To remove the pilasters, first, remove the shelves and shelf brackets. Then, simply lift the
pilaster up and out.
Operation / Maintenance

9
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Condenser Coil Cleaning Instructions:
A dusty condenser may lead to high energy consumption, less cooling eectiveness,
and compressor damage.
The condenser coil is located at the bottom behind the panel.
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and/or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a
vertical direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment
retailer. Ex. Noble Chemical Tech Line
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.

10
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Food Pan Layouts: SPPT
14.5”
13.375”
13.375”
12.75”
12.75”
13.375”
12.75”
24.25”
42.5”
56.25”
66”
6.5” 6.5” 6.5” 6.5” 6.5” 6.5”
33”
6.5” 6.5”4.33”
7”
7”
7”
7” 7” 7” 7” 7” 2.5” 7” 7” 7” 7”
7” 7” 7” 7” 7” 7” 7”
7” 7” 7” 7” 7”
7”
14.5”
7” 7”
(6) 1/6 Size, (2) 1/9 Size
178SSPT27
(12) 1/6 Size, (6) 1/3 Size
178SSPT48
(16) 1/6 Size, (8) 1/3 Size
178SSPT60
(18) 1/6 Size, (9) 1/3 Size
178SSPT71
(10) 1/6 Size
178SSPT36

11
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Food Pan Layouts: SPPT-M
(9) 1/6 Size, (3) 1/9 Size
178SSPT27M
(18) 1/6 Size
178SSPT48M
(24) 1/6 Size
178SSPT60M
(30) 1/6 Size
178SSPT71M
(15) 1/6 Size
178SSPT36M
21.5”21.5”21.5”21.5”
7” 7”7”7” 7”7”
24.25”
42.25”
56.25”
66”
2.5”
3.3”
6.5”
6.5”
6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5”
6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5”
6.5” 6.5” 6.5” 6.5” 6.5”
6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5” 6.5”4.33”
33”
21.5”
7” 7”7”
7”7”7”
7”7”7”

12
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Food Pan Layouts: SPPT1
178SSPPT260
(7) 1/3 size
44.5”
63.3”
84.5”
13.25”
13.25”13.25”
8.9”
7.15”
7.15”
7.15”
7.15”
7.15”8.9”
7”
7” 7” 7” 7” 7” 7” 7” 7” 7” 7”
7” 7” 7” 7” 7” 7”
8.9” 8.9”
7”
6”
6” 6” 6”
6” 6”
7” 6”
8.9”
(5) 1/3 Size
178PICL1
(9) 1/3 Size
178PICL2
(12) 1/3 Size
178PICL3
44.5”
63.3”
84.5”
13.25”
13.25”
13.25”
8.9”
7.15”
7.15”
7.15”
7.15”
7.15”8.9”
7”
7” 7” 7” 7” 7” 7” 7” 7” 7” 7”
7” 7” 7” 7” 7” 7”
8.9” 8.9”
7”
6”
6” 6” 6”
6” 6”
7” 6”
8.9”
(5) 1/3 Size
178PICL1
(9) 1/3 Size
178PICL2
(12) 1/3 Size
178PICL3
44.5”
63.3”
84.5”
13.25”13.25”
13.25”
8.9”
7.15”
7.15”
7.15”
7.15”
7.15”8.9”
7”
7” 7” 7” 7” 7” 7” 7” 7” 7” 7”
7” 7” 7” 7” 7” 7”
8.9” 8.9”
7”
6”
6” 6” 6”
6” 6”
7” 6”
8.9”
(5) 1/3 Size
178PICL1
(9) 1/3 Size
178PICL2
(12) 1/3 Size
178PICL3
PICL2-60
52.6"
13.25"
7.16 7 7 7 7 7 10.4
7

13
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Drawer Pan Layouts: SPPT
178SSPPT1 178SSPPT260
ELEVATION
PLAN
1130
1399
SECTION VIEW
800
875
50
640
582
638
178SSPPT2
ELEVATION SECTION VIEW
PLAN
800
1726
1399
875
50
640
582
638
638
400
178SSPPT3
ELEVATION
PLAN
2383
1399
SECTION VIEW
800
875
50
640
582
638
638
638
400
ELEVATION SECTION VIEW
PLAN
800
1524
1399
875
50
640
582
436
638
400
SLIM DRAWER

14
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Item # Size
178SSPT27HC 178SSPT36HC 178SSPT48HC 178SSPT60HC 178SSPT72HC
178SCLB15354
13⁄" x ⁄" 2 2
178SCLB15327
12⁄" x ⁄" 2 2 2
178SCLB25354
13⁄" x 1" 3 4
178SCLB25327
12⁄" x 1" 5 7 7
178SCLB90354
12⁄" x 3⁄" 1
Item # Size
178SSPT27MHC
178SSPT36MHC 178SSPT48MHC 178SSPT60MHC 178SSPT72MHC
178SCLB15532
20⁄" x ⁄" 2 2
178SCLB25532
20⁄" x 1" 3 4 6 8 11
178SCLB9032
20⁄" x 3⁄" 1
178SCLB10853
20⁄” x 4⁄” 1
Item # Size 178SSPPT1 178SSPPT260 178SSPPT2 178SSPPT3
178PICB15331
13" x ⁄" 2 2 2 2
178PICB25331
13" x 1" 3 5 6 10
Large Divider Bar
13" x 2⁄" 1 1 ( 13” x 4⁄”) 1 ( 13” x 5⁄”) 1
Food Pan Layouts: SS-PT
Food Pan Divider Bars: SS-PT-M
Food Pan Divider Bars: SSPPT

15
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Troubleshooting
Problem Possible Solution
Compressor is
Not Running
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker
Power cord unplugged
Plug in power cord
Thermostat set too high
Set thermostat to lower temperature
Cabinet in defrost cycle
Wait for defrost cycle to finish
Cabinet Temperature
is too Warm
Thermostat is set too high
Set thermostat to lower temperature
Airflow is blocked
Re-arrange products to allow for proper airflow
Make sure there is at least four inches of clearance from the evaporator
Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker
Dirty condenser coil
Clean the condenser coil
Evaporator coil iced over
Ensure doors are closed when not in use
Avoid opening doors for long periods of time
Low refrigerant levels
Contact a service technician to check refrigerant levels
Door is slightly ajar
Make sure doors are completely closed

16
User Manual
www.AvantcoRefrigeration.com
Refrigerated Prep Tables
Troubleshooting
Problem Possible Solution
Condensing Units Run
for Long Periods of Time
Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down
Prolonged door opening or door ajar
Ensure doors are closed when not in use
Avoid opening doors for long periods of time
Door gasket(s) not sealing peroperly
Ensure gaskets are snapped in completely
Remove gasket and replace if necessary
Dirty condenser coil
Clean the condenser coil
Evaporator coil iced over
Unplug unit and allow coil to defrost
Make sure thermostat is not set too cold
Ensure that door gasket(s) are sealing properly
Condensation is
Collecting on the
Cabinet and/or Floor
Gasket is not sealing properly
Clean, repair, or replace the gasket as necessary
Relative humidity is above 60%
Move unit to area below relative humidity or lower humidity level
Produkt Specifikationer
Mærke: | Avantco |
Kategori: | Køleskab |
Model: | SS-PT-27-HC |
Har du brug for hjælp?
Hvis du har brug for hjælp til Avantco SS-PT-27-HC stil et spørgsmål nedenfor, og andre brugere vil svare dig
Køleskab Avantco Manualer
16 Juni 2025
15 Juni 2025
15 Juni 2025
14 Juni 2025
14 Juni 2025
14 Juni 2025
14 Juni 2025
14 Juni 2025
14 Juni 2025
14 Juni 2025
Køleskab Manualer
- Snaigė
- Delfield
- GOTIE
- Samsung
- Becken
- Orbegozo
- Junker
- Kenmore
- Telefunken
- InAlto
- Salton
- Frilec
- Paulmann
- Airflo
- Ilve
Nyeste Køleskab Manualer
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025
19 Juni 2025