AVTech - Velleman CAMCOLD-CK Manual


Læs gratis den danske manual til AVTech - Velleman CAMCOLD-CK (20 sider) i kategorien Sikkerhed. Denne vejledning er vurderet som hjælpsom af 12 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 6.5 anmeldelser. Har du et spørgsmål om AVTech - Velleman CAMCOLD-CK, eller vil du spørge andre brugere om produktet?

Side 1/20
CAMCOLD/CK_v2 1 VELLEMAN
CAMCOLD/CK – CONTROLLER KEYBOARD FOR DOME CAMERA
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on this unit or the package indicates that disposal of this unit after its lifecycle could harm the
environment.
Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be brought to a specialized
company for recycling.
This unit should be returned to your distributor or to a local recycling service.
Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities
Thank you for buying the CAMCOLD/CK! If the device was damaged in transit, contact your dealer.
2. Features
Can control up to 99 cameras
Ability to control 99 normal scanner heads, 1 scanner head, low speed scanner head (less than 24°/sec),
variable speed scanner head
Joystick makes for easy manipulation
Each scanner head can have 64 pre-programmed positions
Delay time can be set between 1~60 sec
Presets: only available on dome cameras disposing of the preset function
Clearly legible LCD display
RS-485 interface
Normal scanner head / control electronic lens and scanner head via decoder (each decoder has 2 ON/OFF
switches)
Normal recording/lens all in one scanner head
Low speed scanner head can have 64 pre-positions, slow speed control (<24°/sec)
High speed, variable speed scanner head can have 64 preset points, variable speed control
3. Specifications
Power: adapter 9-12VDC / 400mA (not included)
Control protocol: RS-485
Transfer speed: 9600 bit/sec
Dimensions: 265 x 175 x 80mm
Weight: 0.95kg
4. Connection
1 (grey), 2 (white) – DC 9V-12V
3 (black), 4 (red) – RS485 control A
5 (green), 6 (yellow) – RS485 control B
7 (blue), 8 (brown) - Ground
CAMCOLD/CK_v2 2 VELLEMAN
ATTENTION: Please be careful on the sequence of pin wires - colour
Signal A: Connect all cameras together on connector RS-485-A (connector K2)
Signal B: Connect all cameras together on connector RS-485-B (connector K2)
Do not inverse A with B.
Connect all connections from keyboard connector A with camera connector 1A, camera connector 2A, …
1. Control wires: Connect the RS485 A and B wires from the keyboard to the A and B wires respectively
from the camera, the A and B wires respectively from the port of the scanner head, etc.
2. Terminal resistance: Connect a terminal resistance of 120 to the 2 extreme points of the decoder or
scanner head. Other components do not need resistance.
3. Matching resistance of 120: Wires or ON/OFF switches are on the keyboard. Jumper K4 in the
keyboard is for the matching resistance. When switched to ON, the resistance is connected to the
extremity; otherwise, on effect.
1. Connecting 1 dome camera (with PELCO-D protocol)
1. Connect controller signal A to camera signal A.
2. Connect controller signal B to camera signal B.
3. Establish the camera address as address 1 (00000001) see 4.1
4. Establish the camera protocol (standard protocol is PELCO-D protocol). Usually, you do not need to change
the protocol because the controller uses the Pelco-D protocol.
See 4.1 to change the protocol.
You can also modify the protocol by using the “F4” button on the controller.
4.1 How to set up the PELCO-D protocol
On the camera (bottom of the camera) there is a DIP switch enabling you to adjust the address and the
protocol of the camera. The first six switches are for the address (from 1 to 63). It is possible to connect 64
cameras. The last 2 switches serve to set up the protocol.
12345678 = DIP switch nr.
Address 1 => 00000001 Characters in bold and italic: Pelco-D protocol
Address 2 => 10000001 78
Address 3 => 01000001 01
Address 4 => 11000001
Address 5 => 00100001
Address 6 => 10100001
Address 7 => 01100001
Address 8 => 11100001
Address 9 => 00010001
Address 10 => 10010001
Etc.….
‘1’ in the table means the switch is ON; ‘0’ in the table means the switch is OFF.
4.2 How to set up the PELCO-P protocol
12345678 = DIP switch nr.
Address 1 => 00000010 Characters in bold and italic: Pelco-P protocol
Address 2 => 10000010 78
Address 3 => 01000010 10
Address 4 => 11000010
Address 5 => 00100010