MODEL 751
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. To reduce the risk of electrical shock, do not use this fan with
any solid-state speed control.
10. Not for use in kitchens.
11. Do not install in a ceiling insulated to a value greater than R-40.
12. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further information
and requirements.
VENTILATION FAN
WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site,
install housing during the rough-in construction of the building. The
blower unit, reflector and grille should be installed after the finished
ceiling is in place.
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4” round duct.
2. Plan duct run from discharge opening of fan to the outside. For
best fan performance, make duct run as short as possible and
use minimum number of elbows.
3. Use optional Broan ducting accessories as needed.
WIRING
Plan to run 120 VAC house wiring (with ground) from power source,
through wall switch, to junction box in housing. For separate control
of fan and light use an optional Broan switch.
IMPORTANT: Use wire suitable for 90
o
C.
Wiring
Knockouts
FIGURE 1
Housing
Scroll
Slots
Power/Blower
Unit
Reflector
Assembly
Acorn Nut
Grille/Lens
Assembly
Mounting
Springs (2)
Duct
Collar
Tabs
Hanger Bars
Page 2
MODEL 751
INSTALLATION IN A
NEW CONSTRUCTION SITE
PREPARATION
1. Refer to Figure 1. Remove power unit/blower assembly from
housing.
A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds
power/blower unit mounting plate in place. Save screw.
C. Lift mounting plate at end near the plug-in receptacle until blower
wheel clears the scroll.
D. Remove plate by pulling its tabs out of slots in housing. Set power/
blower unit aside until needed.
MOUNTING THE HOUSING
MOUNTNG USING MOUNTING TABS
Refer to Figure 2.
1. Locate fan housing next to ceiling joist.
2. Use wood screws (not provided) to loosely attach housing to
ceiling joist through the keyhole slots in mounting tabs.
3. Adjust housing so that it will be flush with finished ceiling. For the
grille to fit properly, the housing’s rim must not extend beyond
finished ceiling surface.
4. When housing is properly adjusted, tighten screws in slots.
MOUNTING USING HANGER BARS
Refer to Figure 3.
1. Insert hanger bars in slots provided in housing.
2. Locate fan housing between joists so that the bottom of the
housing is even with the planned finished ceiling. Extend the
hanger bars to the joists.
3. Use screws or nails (not provided) to secure hanger bars to ceiling
joists.
INSTALLING DUCTWORK
1. Refer to Figure 2. Place duct collar over flanges at discharge
opening of fan. Secure collar by snapping tabs into slots in flanges.
2. Run 4” round duct from fan’s discharge opening to the outside
and terminate.
3. Connect duct to fans duct collar.
WIRING
All wiring must comply with local codes and unit must be
properly grounded.
1. Run 120vAC house wiring (with ground) from wall switches to
fan location.
2. Insert and secure an approved box connector into wiring entrance
hole.
3. Pull wires through box connector and into junction box. Tighten
box connector.
4. Refer to Figure 4. Connect white wires from the fan and light
wire from fan receptacle (black) to wire from fan switch. Connect
blue wire from light receptacle (white) to wire from light switch.
5. Connect the green (or bare) ground wire to the green ground
lead.
B
L
U