MODELS • L900L • L1500L
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.
LOSONE SELECT
®
VENTILATORS
In-Line • 120V
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
This manual is divided into sections as follows:
“TYPICAL INSTALLATION”
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (straight-through blower discharge)
“MOUNTING OPTIONS”
“WIRING OPTIONS”
-Wiring Plate Position
“DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (right-angle blower discharge)
“USE AND CARE”
“SERVICE PARTS”
“WARRANTY”
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 3.
Page 1
MODELS • L900L • L1500L
Page 2
TYPICAL INSTALLATION
MOUNTING
(New Frame Construction)
CEILING
JOIST
(24
centers
shown)
12” ROUND
DUCT
(OUTLET)
ACCESS
PANEL
Factory-shipped unit installed in new construction.
MOUNTING
SCREWS
ACCESS
PANEL SCREW
Ventilator factory-shipped
in straight-through
discharge position.
MOUNTING
BRACKETS
MOUNTING
(Existing Frame Construction)
Factory-shipped unit installed in existing construction.
TYPICAL INSTALLATION
WIRING
WIRING
PLATE
WHITE
TO
WHITE
BLACK
TO
BLACK EDGE
OF HOUSING
120 VAC LINE IN
GROUND TO
WIRING PLATE
ACCESS
PANEL
SCREW
DUCTING
(Straight-through blower discharge)
Two ways to connect ductwork to a factory-shipped unit.
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
ROOF CAP
12ROUND
ELBOW
12
ROUND
DUCT
WALL
CAP
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
8” X 12”
TO
12ROUND
TRANSITIONS
8” X 12” TO 12” ROUND
TRANSITIONS
12” ROUND DUCT
(OUTLET)
FINISHED
CEILING
MATERIAL
Ventilator
factory-shipped
in straight-through
discharge position.
MOUNTING
BRACKETS
8” X 12” TO
12” ROUND
TRANSITIONS
CEILING
JOIST
(24” centers
shown)
ACCESS PANEL
12” ROUND
DUCT
(INTAKE)
12” ROUND
DUCT (INTAKE)
12
ROUND
DUCT
GRILLE NUT
(Install into square
holes in housing)
GRILLE NUT
(Install into
square holes in
housing)