Læs gratis den danske manual til BTI Aqua-Solutions FLC1000 (2 sider) i kategorien Vandfilter. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 2 anmeldelser. Har du et spørgsmål om BTI Aqua-Solutions FLC1000, eller vil du spørge andre brugere om produktet?

Side 1/2
FILTRATION SYSTEM INSTALLATION INSTRUCTIONS
ITEM FL1000
www.btiaquasolutions.com
REV / /1811 19
Remove mounting-bracket from
Filtration System Head. Select Snap
Fit (two outside screws) or Rotary
(one center screw) bracket mounting.
The Rotary bracket mounting should
Filtration System is required in cabinet.
SPECIFICATIONS
NSF/ANSI 42 & 53 CERTIFIED
0.5 MICRON CARBON-BLOCK FILTER
.55 US GAL/2.1L GPM FLOW RATE
1500 US GAL/5,678 L CAPACITY
3-STAGE FILTER
3 x 11 SPACE SAVING DESIGN
BUILT-IN PRV
SQC HEAD
ECO-FRIENDLY, RECYCLABLE
TOOLS REQUIRED:
PENCIL, SCREWDRIVER
TO VIEW INSTALLATION VIDEO VISIT
www.btiaquasolutions.com
1 2
Measure and mark screw hole(s) for
your desired lter location.
Make sure Location-Lug on bracket
is on top.
3
A
Position Filtration System with label and
black location arrow facing you.
Push the lter head into bracket until you
feel it click into place.
It will only t one way, with label and
black location arrow facing you.
4
Push one end of tubing (F) into angle shut-
off valve (D). Push other end of tubing into
L-Fitting, pre-installed in the inlet on top
of lter.
Push one end of tubing (F) into outlet
connector on top of lter. Connect other end
of tubing to faucet-stem of ltration faucet.
If using a BTI Filtration Faucet, all items for
connection are supplied with faucet.
To remove a tube, push down on the collet
while pulling on the tube.
Turn on the water supply and check for
leaks. Flush at least one gallon of water
through the system before use. Write the
installation and lter change dates on the
label for future reference.
Location-Lug
NOTE: If using with a BTI
Hot/Cold Filtration Faucet, skip to Step 5.
Install angle shut-off valve (D) supplied with
BTI Filtration System.
Shut-off cold-water supply (E). Disconnect
line/hose (C) to kitchen faucet from cold-water
supply shut-off valve (E).
Connect angle shut-off valve (D) to cold-water
supply shut-off valve (E). Connect line/hose
from kitchen faucet (C) to angle shut-off valve
(D).
Cut the 1/4 O.D. inlet/outlet tubing (supplied)
to the correct lengths, ensuring the cut ends
are square and clean.
(A) FILTRATION FAUCET
(B) BTI FILTRATION SYSTEM
(C) LINE/HOSE TO KITCHEN FAUCET
(D) ANGLE SHUT-OFF VALVE (supplied)
(E) COLD-WATER SUPPLY SHUT-OFF VALVE
(F) 1/4 O.D. TUBING (supplied)
B
C
D
E
F
F
FILTRATION SYSTEM INSTALLATION WITH COLD ONLY FILTRATION FAUCET
FILTRATION SYSTEM INSTALLATION INSTRUCTIONS, continued
ITEM FL1000
www.btiaquasolutions.com
REV / /1811 19
A
5
Connect 3/8 Female Side of adapter (G)-
(supplied) to braided blue label
cold-water in hose. Push one end of tubing
(F) into 1/4 Push-Fit Side of adapter (G).
Push other end of tubing (F) into “outlet”
connector on top of filter.
To remove a tube, push down on the collet
while pulling on the tube.
Turn on the water supply and check for
leaks. Flush at least one gallon of water
through the system before use.
Write the installation and filter change dates
on the label for future reference.
Install angle shut-off valve (D) supplied with
BTI Filtration System.
Shut-off cold-water supply (E). Disconnect
line/hose (C) to kitchen faucet from cold-water
supply shut-off valve (E).
Connect angle shut-off valve (D) to cold-water
supply shut-off valve (E). Connect line/hose
from kitchen faucet (C) to angle shut-off valve
(D).
Cut the 1/4 O.D. inlet/outlet tubing (supplied)
to the correct lengths, ensuring the cut ends
are square and clean.
Push one end of tubing (F) into angle shut-
off valve (D). Push other end of tubing into
L-Fitting, pre-installed in the inlet on top
of lter.
(A) FILTRATION FAUCET
(B) BTI FILTRATION SYSTEM
(C) LINE/HOSE TO KITCHEN FAUCET
(D) ANGLE SHUT-OFF VALVE (supplied)
(E) COLD-WATER SUPPLY SHUT-OFF VALVE
(F) 1/4 O.D. TUBING (supplied)
(G) w/faucet3/8 / 1/4 ADAPTER (supplied )
B
C
D
E
F
F
FILTRATION SYSTEM INSTALLATION W BTI HOT/COLD FILTRATION FAUCET/ AQUA-SOLUTIONS
ITEMS:
HC2100, HC2200, HC2400
G


Produkt Specifikationer

Mærke: BTI Aqua-Solutions
Kategori: Vandfilter
Model: FLC1000

Har du brug for hjælp?

Hvis du har brug for hjælp til BTI Aqua-Solutions FLC1000 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Vandfilter BTI Aqua-Solutions Manualer

Vandfilter Manualer

Nyeste Vandfilter Manualer