Camille Bauer SIRAX BT5600 Manual

Camille Bauer Måling SIRAX BT5600

Læs gratis den danske manual til Camille Bauer SIRAX BT5600 (28 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 2 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 1.5 anmeldelser. Har du et spørgsmål om Camille Bauer SIRAX BT5600, eller vil du spørge andre brugere om produktet?

Side 1/28
Device handbook
SIRAX BT5600
Operating Instructions SIRAX BT5600
Camille Bauer Metrawatt AG
Aargauerstrasse 7
CH-5610 Wohlen/Schweiz
Tel: +41 56 618 21 11
Fax: +41 56 618 21 21
info@cbmag.com
www.camillebauer.com
PM 1002799 000 00 Device handbook SIRAX BT5600 2/28
Contents
1. Legal informations ……………………………………………………………………………………………………… 3
1.1 Safety and warning notices ………………………………………………………………………………………………… 3
1.2 Qualified personnel ……………………………………………………………………………………………………… 3
1.3 Intende use ……………………………………………………………………………………………………………… 3
1.4 Disclaimer of liability ……………………………………………………………………………………………………… 3
1.5 Feedback ……………………………………………………………………………………………………………… 3
1.6 Repair work and modifications …………………………………………………………………………………………… 3
1.7 Calibration and new adjustment …………………………………………………………………………………………… 3
1.8 Cleaning ………………………………………………………………………………………………………………… 4
1.9 Disposal ………………………………………………………………………………………………………………… 4
1.10 Return ………………………………………………………………………………………………………………… 4
2. Introduction ……………………………………………………………………………………………………………… 4
2.1 Purpose of this document ………………………………………………………………………………………………… 4
2.2 Scope of supply ………………………………………………………………………………………………………… 4
2.2 Further documents ……………………………………………………………………………………………………… 4
3. Functional description ………………………………………………………………………………………………… 4
3.1 Measurement reading screen ……………………………………………………………………………………………… 5
4. Mechanical mounting …………………………………………………………………………………………………… 5
4.1 DIN Rail Mounting ………………………………………………………………………………………………………… 5
4.2 Panel Mounting ………………………………………………………………………………………………………… 6
5. Electrical connections …………………………………………………………………………………………………… 6
5.1 General safety notes ……………………………………………………………………………………………………… 6
5.2 DIN Rail version …………………………………………………………………………………………………………… 7
5.3 Panel version …………………………………………………………………………………………………………… 7
5.4 Measuring output leads ………………………………………………………………………………………………… 8
5.5 Power supply …………………………………………………………………………………………………………… 8
5.6 Measurement connection diagram ………………………………………………………………………………………… 8
5.7 Modbus/RTU interface RS485 ……………………………………………………………………………………………… 8
5.8 USB programming interface ……………………………………………………………………………………………… 9
6. Commissioning ………………………………………………………………………………………………………… 9
7. Programming ……………………………………………………………………………………………………………10
7.1 Password protection ………………………………………………………………………………………………………10
7.2 Setup Menu selection ……………………………………………………………………………………………………10
7.2.1 RS485 Modbus/RTU address setting ……………………………………………………………………………………… 11
7.2.2 RS485 Modbus/RTU baud rate setting ……………………………………………………………………………………11
7.2.3 RS485 Modbus/RTU parity selection setting ………………………………………………………………………………11
7.2.4 High TAP (maximum TAP number) setting …………………………………………………………………………………12
7.2.5 Low TAP (minimum TAP number) setting …………………………………………………………………………………12
7.2.6 High input (IP) resistance limit setting ……………………………………………………………………………………13
7.2.7 Low input (IP) resistance limit setting ……………………………………………………………………………………13
7.2.8 Output 1 (OP 1) type setting ……………………………………………………………………………………………14
7.2.9 Output 1 (OP 1) higher limit setting ………………………………………………………………………………………14
7.2.10 Output 1 (OP 1) lower limit setting ………………………………………………………………………………………15
7.2.11 Output 2 (OP 2) type setting ……………………………………………………………………………………………15
7.2.12 Output 2 (OP 2) higher limit setting ……………………………………………………………………………………… 16
7.2.13 Output 2 (OP 2) lower limit setting ………………………………………………………………………………………16
7.2.14 Open circuit (OC) value of output 1 (OP 1) setting …………………………………………………………………………17
7.2.15 Open circuit (OC) value of output 2 (OP 2) setting …………………………………………………………………………17
7.2.16 System type setting ……………………………………………………………………………………………………18
7.2.17 Lead resistance setting …………………………………………………………………………………………………18
7.2.18 Startup (St) value of OP 1 setting ………………………………………………………………………………………19
7.2.19 Startup (St) value of OP 2 setting ………………………………………………………………………………………19
7.2.20 Auxilary supply frequency setting ………………………………………………………………………………………20
7.2.21 Password (code) setting ………………………………………………………………………………………………20
7.2.22 Default setting …………………………………………………………………………………………………………20
7.2.23 Out (Exiting) from setup setting …………………………………………………………………………………………21
8. Interface definition Modbus/RTU (RS485) ………………………………………………………………………………21
8.1 Accessing 3X and 4X register for reading measured values …………………………………………………………………22
8.2 Accessing 4X register for reading & writing settings …………………………………………………………………………23
9. Technical data ……………………………………………………………………………………………………………25


Produkt Specifikationer

Mærke: Camille Bauer
Kategori: Måling
Model: SIRAX BT5600

Har du brug for hjælp?

Hvis du har brug for hjælp til Camille Bauer SIRAX BT5600 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Camille Bauer Manualer

Måling Manualer

Nyeste Måling Manualer

IFM

IFM SU8631 Manual

13 September 2025
IFM

IFM SV8151 Manual

13 September 2025
IFM

IFM SV7051 Manual

13 September 2025
IFM

IFM SU8030 Manual

13 September 2025
Chauvin Arnoux

Chauvin Arnoux C.A 6524 Manual

12 September 2025
Chauvin Arnoux

Chauvin Arnoux C.A 6117 Manual

12 September 2025
Chauvin Arnoux

Chauvin Arnoux C.A 6526 Manual

12 September 2025
Chauvin Arnoux

Chauvin Arnoux C.A 6532 Manual

12 September 2025
Janitza

Janitza UMG 96-EL Manual

11 September 2025