CDN SD2210X Manual

CDN Køkkenvægt SD2210X

Læs gratis den danske manual til CDN SD2210X (4 sider) i kategorien Køkkenvægt. Denne vejledning er vurderet som hjælpsom af 44 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 22.5 anmeldelser. Har du et spørgsmål om CDN SD2210X, eller vil du spørge andre brugere om produktet?

Side 1/4
Features
• NSF® Certied
• Submersible (IP67: protected from water up to 3 feet
for 30 minutes, completely protected against dust)
• Programmable
• Tare function
• Backlit display
• Field calibration
• Low/high limit alerts
• Stability indication
• Overload indication
• Battery status indication
• Stainless steel housing
• Removable stainless steel platform
• On/off button
Auto-off after 2 minutes, programmable to 5 minutes;
disabled when AC adapter used
Platform Size: 7.2 W x 6.7 L (in)/18.2 W x 17.0 L (cm)
• Resolution: 0 lb:0.1 oz, 0 lb:1/8 oz, 0.005 lb,
0.05 oz, 1/8 oz, 1 g
• Rechargeable battery: 4.8V 1800mAH (built-in)
• Power Adapter: 100-240VAC 50/60Hz input, 9V DC
(1000mA) output (included)
Note: Clean the scale before each use.
Note: In the following instructions, names of the
control buttons are shown in CAPS. Function
information that appears on the display is shown in
BOLD CAPS.
Power Adapter
Before using the external power adapter, make sure
that the printed voltage complies with the local
voltage.
Note: Use only an original CDN power adapter (AD-AC1110).
The use of other adapter is subject to approval by CDN.
1. Insert the adapter plug into the jack in the rear
of the scale.
2. To turn the scale on, press the POWER button
( ) as described in Section A: On/Off. The scale will
remain on until turned off.
Note: When the power adapter is plugged in, the auto-off
feature is disabled.
Charging the Battery
The icon ( ) and appear on LOW BATTERY bAtt
the display when battery status is low and needs
to be charged. The icon ( ) ashes LOW BATTERY
continuously while charging. The battery is built-in and
does not need to be replaced.
1. Insert the adapter plug into the jack on the back
of the scale. Allow the scale to charge for
5 hours. The scale will then operate continuously for
approximately 14 hours
Operating Instructions
Place the scale gently on a hard and at surface
and make sure it is steady before use to obtain
accurate measurements.
A. On/Off
A. Press the POWER button ( ) to turn on.
The display ashes all segments and then
returns to zero.
B. The STABILITY icon ( ) appears in the lower left
corner of the display when the weight is stable.
C. Press the POWER button ( ) to turn off.
B. Auto Off
The scale automatically turns off after 2 minutes of
inactivity.
Note: Auto-off is disabled when the AC adapter is used.
Model: SD2210X
ProAccurate
®
Submersible Scale
22 pounds/10 kilograms/352 ounces
by pounds:ounces, ounces, fractional ounces and grams
C. Backlit Display
Press and hold the UNIT button for 3 seconds
to turn the backlit display on and off.
D. Unit Selection
Press the UNIT button to select the desired unit. The
display cycles through g, , , lb:oz lb:/oz lb, oz, and /oz.
E. Tare
The tare function resets the scale display to zero
in order to measure only the weight of an item. It is
frequently used to subtract the weight of containers.
1. When the scale is on, place a container on
the platform.
2. Press the TARE button to reset the display
to zero.
3. Place the item into the container or directly on
the scale platform. The weight of only the last
item added will appear on the display.
4. Continue to repeat steps and 2. 3. to measure
the respective weights of additional items.
5. To clear the tare, remove all items from the
platform and press the TARE button. The display
is reset to zero.
F. Low/High Limit Alerts
The scale may be set to alert you when an item’s
weight is under or over a set limit.
1. Press and hold the TARE button for 3 seconds.
The scale beeps as and the zero weight LOW
appears on the display.
2. Place a weight equal to the low weight limit on
the platform and press the SET button. A beep
indicates that the low limit is set.
3. HIGH appears on the display. Add weight to the
platform until the weight is equal to desired
high weight limit. Press the SET button. A beep
indicates that the high limit is set.
4. Remove all items from the platform.
5. An alert will now sound if an item placed on
platform is over or under the set limits. LOW
or appears on the left side of the display HIGH
when these conditions exist.
6. To clear the Low/High limits, press both SET and
TARE buttons simultaneously.
G. Field Calibration
1. When scale is off, press and hold POWER button
( ) until the scale turns on. When all segments
are on, release the POWER button ( )
and press the UNIT button 3 times within one
second. The display shows , then , 11111 55555
and then the version number and checksum
appear before resetting to zero.
2. Making sure there is no load on the platform,
press the SET button to save the zero value.
3. Put a 10 kg (or two 5 kg) calibration weight on
the platform.
4. Press the SET button again to start the
auto-calibration. The scale shows 5000 g
and then before automatically turning off. CAL
The calibration is complete.
H. Battery Status
Battery status is low and needs Low Battery:
to be charged. See on Charging the Battery
page 1.
I. Error Messages
oL indicates an overload when the item being
measured exceeds the capacity of the scale.
Immediately remove the overweight item to avoid
causing permanent damage to your scale.
J. Programmable Modes
The scale has been pre-congured at the factory
and should not require conguration for use in most
applications. In the event that the factory settings
do not meet the requirements of your application,
the following describes the steps
to congure the scale.
1. Units
The scale has been pre-congured at the factory
for six units of measure. In the event that these
do not meet the requirements of your application,
the following describes the steps
to limit the number of unit choices available. The
sequence of units is , , , , lb:oz lb:/oz lb oz
/oz and .g
a. Press the POWER button ( ) to turn on.
b. Press and hold the SET button for 3 seconds.
When appears on the display, release the SEt
SET button to enter the conguration mode.
UNIT appears on the display.
c. With UNIT appearing on the display, press the
SET button to select lb/OZ (pounds/ounce)
units (11 lb @ 0.1 oz). Both the unit and its
status appear on the display.
d. Press the UNIT button to toggle between
ON (enabled) and OFF (disabled).
e. Press the SET button to conrm the status
and to select the next unit in the sequence.
f. Repeat steps d. and e. for each respective
unit. Upon conrming the status for , g
UNIT appears on the display.
g. Press the UNIT button three times.
END appears on the display.
h. Press the SET button to save the settings and
return to weighing mode.
2. Auto Off
The scale has been pre-congured at the factory
to automatically turn off after 120 seconds
(2 minutes) of inactivity. In the event that your
application requires longer shut-off times or none
at all, the following describes the steps
to congure this feature.


Produkt Specifikationer

Mærke: CDN
Kategori: Køkkenvægt
Model: SD2210X

Har du brug for hjælp?

Hvis du har brug for hjælp til CDN SD2210X stil et spørgsmål nedenfor, og andre brugere vil svare dig




Køkkenvægt CDN Manualer

CDN

CDN SD2210X Manual

18 August 2024
CDN

CDN SD1110X Manual

18 August 2024
CDN

CDN SD1104 Manual

18 August 2024
CDN

CDN SD5502 Manual

18 August 2024

Køkkenvægt Manualer

Nyeste Køkkenvægt Manualer