Chauvin Arnoux C.A 5277 Manual


Læs gratis den danske manual til Chauvin Arnoux C.A 5277 (36 sider) i kategorien Multimeter. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om Chauvin Arnoux C.A 5277, eller vil du spørge andre brugere om produktet?

Side 1/36
AC+DC TRMS MULTIMETER
C.A 5277
E NGLI S H
User’s manual
2
PRECAUTIONS FOR USE
This instrument is compliant with the NF EN 61010-1 + NF EN -2-030 safety standard for 1000 V voltages in category 61010
III or 600 V in category IV at an altitude below 2000 m, indoors, and with a maximum pollution level of 2.
Failure to comply with safety instructions can create a risk of electric shock, re, explosion destruction of the instrument and
or the installations.
Do not use the instrument in an explosive atmosphere or in the presence of inammable gas or smoke.
Do not use the instrument on networks with a rated voltage or category higher than those mentioned.
Respect the maximum rated voltages and currents between terminals and in relation to the earth.
Do not use the instrument if it seems damaged, incomplete or incorrectly closed.
Before each use, check the condition of the cable insulation, the unit and the accessories. All elements on which
the insulation is damaged (even partially) must be put out of service for repair or disposed of as waste.
Use cables and accessories for voltages according to IEC 61010-031 and measurement categories at least equal to
those of the instrument.
Respect the environmental conditions of use.
Strictly comply with the fuse specications. Disconnect all cables before opening the fuse access cover.
Do not modify the instrument and do not replace components using equivalent parts. Repairs and adjustments must be
carried out by qualied, approved personnel.
Replace the battery as soon as the symbol appears on the display. Disconnect all cables before opening the
battery access cover.
Use personal protection equipment when conditions require it.
Do not place your hands close to instrument terminals that are in use.
When handling sensors or test probes, do not place ngers beyond the physical nger guard.
MEASUREMENT CATEGORI ES
CAT II: Test and measurement circuits directly connected to points of use (power outlets and other similar points) on the
low-voltage network.
E.g. Measurements on circuits i network for household appliances, portable tools and other similar instruments.n
CAT III: Test and measurement circuits connected to parts of the building low-voltage network installation. 's
E.g. Measurements on distribution switchboards (including secondary meters), the circuit breakers, cabling including cables,
busbars, junction boxes, circuit breakers, power outlets in the fixed installation and industrial instruments and other
equipment such as motors permanently connected to the fixed installation
CAT IV: Test and measurement circuits connected to the source of the building low-voltage network installation. 's
E.g. Measurement on equipment installed upstream of the main fuse or building installation cut-off switch.
You have just purchased a multimeter and we thank you for your condence in our products. C.A 5277
To obtain the best service from your instrument :
Read these instructions carefully;
Respect the precautions for use.
Meanings of the symbols used on the instrument.


Produkt Specifikationer

Mærke: Chauvin Arnoux
Kategori: Multimeter
Model: C.A 5277

Har du brug for hjælp?

Hvis du har brug for hjælp til Chauvin Arnoux C.A 5277 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Multimeter Chauvin Arnoux Manualer

Multimeter Manualer

Nyeste Multimeter Manualer

Draper

Draper 52320 Manual

8 Juni 2025
VOREL

VOREL 81780 Manual

7 Juni 2025
Brymen

Brymen BM878 Manual

7 Juni 2025
Brymen

Brymen BM789 Manual

6 Juni 2025
Draper

Draper 16232 Manual

6 Juni 2025
Draper

Draper 41822 Manual

6 Juni 2025
Draper

Draper 41820 Manual

6 Juni 2025
Brymen

Brymen BM805s Manual

6 Juni 2025
Brymen

Brymen BM785 Manual

6 Juni 2025
Brymen

Brymen BM239R Manual

3 Juni 2025