Description
C series thermometers have a high strength, polycarbonate
case with rubber over moulding to provide durability and
protection against dust and water ingress
The Catercheck 3 is based on the C20 but has a xed probe.
C12 HACCP Thermometer
labels so that you can change the colour from blue to red,
green, yellow or orange.
Instructions
Should you wish to change the blue label on your C12
thermometer from the blue label supplied, remove the plastic
protective cover from the C12 Label at the front of the
instrument (if tted). It is not necessary to remove the label
itself. Select the new coloured label and carefully remove the
backing cover to reveal the glued area. Carefully align the
label over the old one and ax into place.
The air and penetration probes provided do not have colour
coding.
1
Overview of Display Symbols
A Main Display for Temperature
B °C Indicat or
C Sensor Type PST (Thermistor)
D Low Battery Indicator
Connecting Probes to the Thermometers
The C12 and C20 thermometer have sockets for probe
connection of Thermistor probes.
Switching On and O
The single ‘ON/OFF’ button on the keypad is used to switch
on the thermometer. After a short pause the display will show
the model of the instrument and will then revert to normal
temperature display.
2
Comark Handheld Thermometers
C12 HACCP ,
C20 and Catercheck 3
Operator Manual
Auto Switch O/Power Saving Mode
C12 and C20 series thermometers have auto-switch o
feature. This is set to 3 minutes.
Care of the Thermometer
C12 and C20 series thermometers are dust and waterproof as
stated in the specications and will withstand harsh
environments. Use a damp cloth or warm soapy water to
remove deposits and prevent them from hardening or
becoming sticky. Do not use solvent-based cleaners or
methylated spirit, etc.
C20
In particularly harsh environments care should be taken to
clean the Lumberg probe connector regularly. This should
ensure it does not become dicult to remove the probe from
the thermometer. The probe should be removed from the
instrument as frequently as necessary, the thread then
cleaned and lubricated with food safe oil.
Caution: Do not place any C12 or C20 series thermometers in
a dishwasher.
Changing the Batteries
The symbol BAT appears on the display when the battery
voltage has reduced. Battery replacement is recommended at
this time.
To replace the battery, remove the battery cover retaining
screw on the rear of the instrument, using the correct size
screwdriver. Remove the two cells, and replace with alkaline
cells only. Be careful to observe the correct polarity. Take
care not to over-tighten the screw when retting the cover.
Note: The C12 and C20 series thermometers will not work if
the battery compartment is incorrectly tted or missing. In this
instance the display will show ‘OPEn’. Please note the small
pip on the inside of the battery cover, which must t into the
hole provided in the back of the case.
3
Trim folded width to
63mm
Specications for C12, C20 and Catercheck 3
Sensor Thermistor 10 K Ohms uni-curve
Connector : 3.5mm Jack C12
C20: 6-pin Lumberg
Measurement Range -40°C to +125°C
Scale °C
Displayed Resolution 0.1°
System Accuracy at 23°C ±0.5°C -20°C to +70°C
Ambient Temperature Range -20°C to +50°C operating
Display 4 digit 12.5 mm LCD
Battery Two of type I.E.C. LR6 Size AA
Battery Life (continuous) up to 14000 Hours
Environmental Protection
C20 Certied IP67, BS 60529, IEC 529
Catercheck 3 Not Certied
C12 Not Certied
EMC Emission Tested to EN61326-1
Criteria B Performance
Dimensions (Excluding Probe)
Length 152mm/6 inches
Width 58mm/2.3 inches
Depth 22/27mm/0.9/1.1 inches
Weight 178g/6.3 ozs
4
Description
Les thermomètres série C ont un boîtier en polycarbonate
haute résistance avec surmoulage, pour garantir la durabilité
et orir une protection contre la pénétration de poussière et
d'eau
Le Catercheck 3 est articulé sur le C20, mais a une sonde
xe.
C12 HACCP Thermomètre
Le thermomètre C12 est livré avec étiquettes couleur codées
de sorte que vous pouvez changer la couleur du bleu au
rouge, vert, jaune ou orange.
Instructions
Si vous souhaitez modier l'étiquette bleue sur votre
thermomètre C12 à partir de l'étiquette bleue fournie, retirez
le couvercle de protection en plastique de l'étiquette C12 à
l'avant de l'appareil (le cas échéant). Il n'est pas nécessaire
d'enlever l'étiquette elle-même. Sélectionnez la nouvelle
étiquette de couleur et retirez avec précaution le couvercle du
support de révéler la zone collée. Alignez soigneusement
l'étiquette sur l'ancienne et xez en place.
Les sondes d'air et la pénétration prévus n'ont pas un code
de couleur.
6
Thermomètres portables Comark
Gamme HACCP C12 ,
C20 et Catercheck 3
Manuel de l'utilisateur
5
Présentation des symboles de l'acheur
A Achage principal de la température
B Indicateur en °C
C Type de capteur PST (Thermistor)
D Indicateur de faible autonomie
Raccordement des sondes aux thermomètres
Les thermomètres C12 et C20 ont des prises réservées au
raccordement des sondes à thermistor.
Mise sous tension et hors tension
Le bouton « ON/OFF » (marche/arrêt) unique du clavier
permet d'allumer le thermomètre. Après une brève pause,
l'acheur indique le modèle de l'instrument, puis revient à
l'achage normal de la température.
7


Produkt Specifikationer

Mærke: Comark
Kategori: Termometer
Model: C12

Har du brug for hjælp?

Hvis du har brug for hjælp til Comark C12 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Termometer Comark Manualer

Comark

Comark N9002 Manual

13 Juni 2025
Comark

Comark C48C Manual

11 Juni 2025
Comark

Comark KM814FS Manual

11 Juni 2025
Comark

Comark PDQ400 Manual

21 August 2024
Comark

Comark C42F Manual

21 August 2024
Comark

Comark BT250 Manual

20 August 2024
Comark

Comark N5001USB Manual

20 August 2024
Comark

Comark T220A Manual

20 August 2024
Comark

Comark KM340 Manual

20 August 2024
Comark

Comark TCF220 Manual

20 August 2024

Termometer Manualer

Nyeste Termometer Manualer

CDN

CDN DTL572 Manual

14 Juni 2025
CDN

CDN TCF400 Manual

14 Juni 2025
CDN

CDN IN1022 Manual

14 Juni 2025
CDN

CDN IN482 Manual

14 Juni 2025
CDN

CDN DTC450 Manual

14 Juni 2025
CDN

CDN TCG400 Manual

13 Juni 2025
CDN

CDN TCH130 Manual

13 Juni 2025