13AMP
SOCKET TESTER
34279 – INSTRUCTIONS FOR USE
EN
2. Specication
Stock No. 34279
Rated Voltage: 230V
Rated Frequency: 50Hz
Test Time: 60 90seconds
Working Temperature: 0 - 40°C
Relative Humidity: <80%
Dimensions: 71 X 62 X 62mm
Net Weight: 63g
1. Product Introduction
1.1 Intended Use
This product is designed to test and nd electrical faults on 13A sockets.
A combination of the three indicator lights and the coding chart provided will
show the condition of the socket wiring. Any other application beyond the
conditions established for use will be considered misuse. Draper Tools accepts
no responsibility for improper use of this product.
Original Instructions
Version 2 June 2024
3. Health and Safety Information
Important: Read all the Health and Safety instructions before attempting to
operate, maintain or repair this product. Failure to follow these instructions may
result in injury or damage to the user, the product or the socket.
WARNING!
• The tester provides an instant reading of the socket wiring. DO NOT LEAVE
INSERTED INTO THE LIVE MAINS SOCKET FOR LONGER THAN THE
MAXIMUM TEST TIME OF 90SECONDS.
• To prevent electric shocks:
Use the correct safety measures when working with voltages above 32V
RMS, 42V AC peak or 60V DC.
DO NOT touch any conductors with hands or skin.
• If a plug adapter must be used to test a socket or a lead connection, ensure
that it is in perfect condition especially the protective conductor connection
to avoid faulty test results.
• Check the tester before each use and use if any damage, broken or DO NOT
cracked parts.
• Before use check the tester with a known voltage source to verify it is in
perfect working order.
• The tester must only be used under the conditions and for the purpose it has
been designed for.
• DO NOT use tester if wet or damaged in any way. Keep it dry and free from dust.
• The tester cannot detect between Neutral/Earth reverse.
Read this manual in full before using this product and retain it for future use. Always use the latest version of the manual.
Please visit drapertools.com/manuals for the latest version.
Helpline: +44 (0) 23 8049 4344 Sales Desk: +44 (0) 23 8049 4333 General Enquiries: +44 (0) 23 8026 6355 Website: drapertools.com Email: sales@drapertools.com
Draper Tools Limited, Hursley Road, Chandlers Ford, Eastleigh, Hampshire, SO53 1YF, UK 0624
4. Identication and Unpacking
4.1 Product Overview Fig.1
1. Indicator light
2. Indicator light
3. Indicator light
4. Coding chart
Fig. 1
(1)
(2)
(4)
(3)
1. Plug the tester into the socket to be tested.
2. The 3 lights will come on in dierent combinations to indicate the
condition of the socket wiring.
3. Refer to the coding chart on the tester and table below for an explanation
of the test results.
5. Operation
Light 1 2 3
Test Results
Coding
Chart
Column 1 Column 2 Column 3
Socket wiring is correct
Live and Neutral wire reversed
Live and Earth wire reversed
No Neutral wire
No Earth wire
No Live wire
6. Maintenance, Storage and Disposal
• When not in use, wipe over with a dry cloth and store in a cool, dry, dust free
and childproof place.
• At the end of its working life, dispose of the product responsibly and in line
with local regulations. Recycle where possible.
• DO NOT dispose of this product with domestic waste; most local authorities
provide appropriate recycling facilities.
WEEE Waste Electrical & Electronic Equipment
Do not dispose of Waste Electrical & Electronic Equipment
in with domestic rubbish
7. Warranty
Warranty period is 12 months from date of purchase. Visit drapertools.com/
warranty for full details.
Socket Tester
Stock No.34279 Part No.ST-2
Correct
L / N Reverse
L / E Reverse
Neutral Fault
No Earth
Live Fault
230V / 50HZ
means Light ON
means Light OFF