Draper 70155 Manual


Læs gratis den danske manual til Draper 70155 (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 4.0 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Draper 70155, eller vil du spørge andre brugere om produktet?

Side 1/1
Draper Tool Limis ted, Hu y Rrsle oa Chan erd, dl s Ford, Eastleigh, Hampsh O53 1YF, UKire, S
Delta International, Delta International BV, Oude Graaf 8, 6002 NL, Weert, Netherlands
GAS WELDING AND
CUTTING EQUIPMENT
SAFETY INSTRUCTIONS
TAJB0421
Helpline: +44 (0) 23 8049 4344 Sales Desk: +44 (0) 23 8049 4333 General Enquiries: +44 (0) 23 8026 6355 internet: drapertools.com email: sales@drapertools.com
material
sparks and flames. Respiratory protection should be used where necessary.
3. Cylinders must be properly secured in an upright position.
4. Regulators must be correct for the gas and the pressure range required. They should be examined for
leaks and any form of damage, particularly to gauges before use.
5. Flashback Arrestors should be fitted to the outlet of the regulator.
attaching the regulators) and regulator bullnosed nipples, seatings and threads must be free from
damage.
through to remove any dirt or dust before fitting nut and hose nipple to 'regulator end' and HCV or
Flashback Arrestor 'blowpipe end' of hose.
8. All hose connections must be free from dirt, in good condition and properly tightened.
oxygen supplies.
10. The regulator P.A. (pressure adjusting) screw must be in the unscrewed (zero pressure) position before
opening the cylinder valve.
11. Blowpipe valves must be in the closed position before opening cylinder valves.
12. The cylinder valves must be opened slowly to prevent a pressure surge and an approved cylinder key
must be used. The key should be left on the cylinder.
13. The regulators must be correctly adjusted to give the manufacturer's recommended pressures for the
cutting or welding nozzles being used and the work to be done. Setting should be carried out in the
flow condition.
14. The hoses must be purged individually, away from naked light, before lighting the blowpipe.
15. The blowpipe should be examined to ensure that it has no leaks before being lit.
16. To light the blowpipe, ignite fuel gas first and then open oxygen valve until a neutral flame is obtained.
experienced close oxygen valve first.
18. The oxygen and fuel gas cylinder valves should be closed firmly.
19. Pressure in the hoses should be released by opening and then closing each blowpipe valve in turn.
20. The regulator P.A. screws should be unscrewed into the zero pressure position.


Produkt Specifikationer

Mærke: Draper
Kategori: Ikke kategoriseret
Model: 70155

Har du brug for hjælp?

Hvis du har brug for hjælp til Draper 70155 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Draper Manualer

Draper

Draper Expert 58140 Manual

9 December 2025
Draper

Draper 29358 Manual

9 December 2025
Draper

Draper Expert 75170 Manual

5 December 2025
Draper

Draper 34570 Manual

4 December 2025
Draper

Draper 34964 Manual

3 December 2025
Draper

Draper Expert 58138 Manual

3 December 2025
Draper

Draper 78641 Manual

3 December 2025
Draper

Draper 78639 Manual

2 December 2025
Draper

Draper 29098 Manual

3 Oktober 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Waterstone

Waterstone 7800 Manual

11 December 2025
Kwikset

Kwikset 258 Manual

11 December 2025
Schlage

Schlage F170 Manual

11 December 2025
Moen

Moen Align 7565EV Manual

11 December 2025
ALNO

ALNO MC10244 Manual

11 December 2025
JET

JET TAK-ZX Manual

11 December 2025
Waterstone

Waterstone 1455 Manual

11 December 2025
Laica

Laica NE2015 Manual

11 December 2025