hat is a programmable room
...an explanation for householders
A programmable room thermostat is both a programmer
and a room thermostat. A programmer allows you to set
‘On’ and ‘Off ’ time periods to suit your own lifestyle. A room
thermostat works by sensing the air temperature, switching
on the heating when the air temperature falls below the
thermostat setting, and switching it off once this set
temperature has been reached.
So, a programmable room thermostat lets you choose what
times you want the heating to be on, and what temperature
it should reach while it is on. It will allow you to select
different temperatures in your home at different times of the
day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher
setting will not make the room heat up any faster. How
quickly the room heats up depends on the design of the
heating system, for example, the size of boiler and radiators.
Neither does the setting affect how quickly the room cools
down. Turning a programmable room thermostat to a lower
setting will result in the room being controlled at a lower
temperature, and saves energy.
The way to set and use your programmable room
thermostat is to find the lowest temperature settings that
you are comfortable with at the different times you have
chosen, and then leave it alone to do its job. The best way to
do this is to set low temperatures first, say 18C, and then
turn them up by one degree each day until you are
comfortable with the temperatures. You won’t have to adjust
the thermostat further. Any adjustments above these settings
will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will
usually be only one programmable room thermostat to
control the whole house. But you can have different
temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators. If you don’t
have TRVs, you should choose a temperature that is
reasonable for the whole house. If you do have TRVs, you can
choose a slightly higher setting to make sure that even the
coldest room is comfortable, then prevent any overheating in
other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating
programme, for example, ‘Override’, ‘Advance’ or ‘Boost’.
These are explained in the manufacturer
Programmable room thermostats need a free flow of air to
sense the temperature, so they must not be covered by
curtains or blocked by furniture. Nearby electric fires,
televisions, wall or table lamps may prevent the thermostat
wer supply 2 X AA 1.5V 230V AC 50Hz
Battery life 3 years typical –
Heating (switch N.O.) 16(2)A 230 Vac
Switch type SPDT (voltage free contacts)
Min. recommended current 10mA @24Vac (inductive)
Ambient temperature Operating 0°C to 50°C
(non condensing). Storage 15% to 95%
Temperature range 0°C to 32°C
Accuracy (between 7°C & 32°C) 0.5°C
Timing resolution 1 minute
Temperature resolution 0.1°C
Rated impulse voltage 2.5KV
Pollution situation Degree 2
Wiring : Designed for fixed wiring only,
to comply with IEE wiring regulations
f you wish to change any of the Installer Options as shown
below, enter the Installer Option Menu from Auto mode by
ressing < and + simultaneously for 5 seconds.
ressing < and + again for 5 seconds will exit the Menu and
Once the Installer Options screen has been selected (Fig 8), the
and > buttons allow you to scroll through the Menu (shown
elow). The + and - allow you to change values. Once a value
as been changed pressing > before exiting the Menu will save
the new setting. (Fig 9 shows Option 1 OFF).
The access protection lock allows the installer to lock the
Digistat+3 so that the user cannot make any adjustments.
he default is OFF mode allowing the users to adjust the
Digistat+3 (see User Guide).
ettings enter the Installer Options Menu
(Refer to Installer Option 1) and select On and press > to accept.
Once the Installer Options Menu is exited all buttons will be
To switch off the Protection Lock enter the Installer Menu and
change to OFF. Press > to accept.
Once the Installer Menu is exited all buttons will be free to adjust.
Freeze protection will switch on the heating if the room
temperature falls to 5ºC and will then control the temperature at
Digistat+3 is in OFF mode.
The freeze protection default is ON.
To switch off the Freeze protection mode enter the Installer
Options Menu (Refer to Installer Options 2) and change to OFF.
Low and High Limit set points.
The user temperature set points defaults are High 32ºC and Low
7ºC, to change these limits enter the Installer Options Menu
(Refer to Installer Options 3 & 4).
Intelligent Delayed Start (Energy saving feature).
The Intelligent Delayed Start is an energy saving feature which
automatically reduces the warm up time for the heating system.
As the weather becomes milder, Intelligent Start will delay the
heating start times so that fuel is not wasted bringing the room
up to temperature earlier than necessary.
Note: Intelligent Delayed Start only applies in Auto mode.
Intelligent Delayed Start default is in OFF mode.
To switch on Intelligent Delayed Start enter the Installer Options
efer to Installer Options 5).
Note the Intelligent Delayed start option is not suitable for
Hydronic underfloor application.
Ensure Installer option 5 is set to Off before final commissioning
for Hydronic underfloor application.
In some hydronic heating systems there may be a requirement to
protect the valve by operating it once a day
without bringing on the heating system.
If valve protection is selected the valve will be operated for a
period as shown in Valve protection time (mins).
Valve protection time every day at 10.00am.
Valve protection default is OFF.
o enable the valve protection mode enter the Installer Options
Menu (Refer to Installer Option 6)
alve protection time (mins).
Valve protection time can be set between 1 and 5 minutes
To change this once a day on time enter the Installer Options
efer to Installer Option 7).
ptions What is it Select between Default
1 Access protection lock On Off Off
2 Freeze protection On Off On
Low limit set point ºC 7 High limit 7
High limit set point ºC Low limit 32 32
(Energy saving feature) On Off Off
Valve protection On Off Off
Valve protection time (Mins) 1 5 3
Sensor fault function On Off Off
hen the display shows an error code (E1) or (E2) this indicates
sensor fault and the heating system will
(E1) = internal sensor and (E2) = external sensor.
f (E2) is shown, first check the external sensor terminal block
onnections before replacing the
Sensor fault function allows you to temporally set the
o cycle the heating system 30% On and 70% Off until you have
his can be done by entering the installer Option Menu (Option
8) and selecting On. Press > to accept.
o reset to default Off, entering the installer Option Menu
Option 8) and selecting Off. Press > to accept.
Battery) can be used for radiator or Hydronic underfloor
In installer Option select:
Mains) can also be used for electric heat applications.
adiator and electric heat.
To change application enter the installer Option Menu and refer
Drayton – day 5:2 day Programmable RoomDigistat+3 7
Allowing different programs for weekdays and weekends and
lso every day of the week can be programmed differently.
(Fig 11) (Fig 12) (Fig 13)
rogram 1 (9 till 5) as shown below
ime 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 20.0 16.0 16.0 16.0 21.0 7.0
ime 7:00 9:00 12:00 14:00 16:00 23:00
Temperature C 20.0 18.0 21.0 18.0 21.0 7.0
rogram 2 (Home for lunch)
Time 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 21.0 16.0 21.0 16.0 21.0 10.0
Time 7:00 9:00 12:00 14:00 16:30 23:00
emperature C 21.0 18.0 21.0 18.0 21.0 10.0
:00 8:30 12:00 14:00 17:30 22:30
Temperature C 21.0 19.0 21.0 19.0 21.0 16.0
Time 7:00 9:00 12:00 14:00 16:30 23:00
Temperature C 21.0 18.0 21.0 18.0 21.0 16.0
ow to change the pre-set time/temperature program to my
Press > to select the day function. Now press + to select the day
r days you wish to change. The days can be selected as blocks or
s individual days (figs 11 to 13).
ig 11 showing Monday to Friday as one block.
ig 12 showing Saturday and Sunday as one block.
Fig 13 showing Monday through to Sunday as individual days.
Once you have selected the required day or days, press > to
view the existing time/temperature event (1). (Fig 14) time will
flash. Press > again to view the temperature setting, temperature
will flash. Press > again to view the second time temperature
When you get to the event you wish to change press + or - to
change the required time, then Press > to accept. Use + or - to
select the required temperature, then > to accept.
will now show the next time/temperature event
until you return to Auto mode.
How to change User Options.
If you wish to change any user options 1 to 8 shown in table 1
they can be accessed from Auto or Man by pressing < and >
simultaneously for 3 seconds. Once you have accessed the user
setting Menu (Fig 15) press > to scroll through selectable
options 1 to 8. The settings for each option can be changed by
pressing + or - as required. Press > to accept the change and
move to the next option. T
o exit press < and > simultaeously for
3 seconds. Alternatively, not pressing any buttons for 2 mins will
Digistat+3 to return to Auto. (Fig 15a) shows option 1
Only selected options which have been accepted by pressing >
How to change from 24hr to 12hr clock (Option 1).
Enter user options, select option 1 and use + and – keys to select
desired option, 12 = 12hr and 24 = 24hr. Press > to accept change.
How to change the default manual set-point temperature
Enter user options, select option 2 and use + and – keys to set
desired temperature. Press > to accept desired change.
How to change to another predefined program 1, 2 or 3
Enter user options, select option 3 and use + and – keys to select
desired program 1, 2 or 3. 1 = program 1, 2 = program 2 and
3 = program 3. Press > to accept desired change.
How to change the number of program events per day
Enter user options, select option 4 and use + and – keys to select
desired option. 2 = 2 time / temp events per day, 4 = 4 time /
temp events per day and 6 = 6 time / temp events per day. Press
> to accept desired change.
How to switch on/off the automatic summer / winter time
Twice a year the actual time is automatically changed to keep it in
line with the summer / winter time change. Default setting is On.
If you wish to disable / enable this feature enter user options,
select option 5 and press – or + key to display Off or On as
desired. Press > to accept desired change.
How to change temperature offset (Option 6).
The temperature displayed on the thermostat may not match
that of other temperature measuring devices in the controlled
space, because of its location. The displayed and set
temperature may be offset to bring it in line with other devices.
To adjust the temperature, enter the user options, select option
6. The temperature may be offset by +/- 5 degrees by pressing
the + and – keys. Press > to accept the desired change.
How to restore the built in time temperature programs
Enter user options, select option 7 and use + and – keys to
select desired option. Off = current programs retained. On =
restore factory program settings. Press > to select the desired
Please note enabling this function will lose any user
changes to the preset programs.
How to switch the and heating system offDigistat+3
To switch the and the heating system off you need toDigistat+3
enable the Off function. Enter user options, select option 8 and
use + or – keys to select On to enable the Off function .The
thermostat and heating system will now be Off unless the
temperature in the controlled space falls below 7
protection set-point. The LCD will display Off and room
temperature only and the keys will not function. To switch On
Digistat+3 enter user options select option 8 and use + or –
keys to select Off to disable the Off function. The thermostat
will now regulate the heating system in line with the currently
selected program. Please note this does not effect the operation
of domestic hot water where provided.
options What is it Min Max Default
1 Change 12h or 24h clock 12 24 24
5 Switch on/off automatic
summer/winter time change On Off On
6 Change temperature offset
7 Restore pre-set programme On Off Off
8 To enable Off function On Off Off
06490044001 Digistat+3 update 7/3/06 11:19 am Page 2