DSC HS2ICN Manual

DSC Alarmsystem HS2ICN

Læs gratis den danske manual til DSC HS2ICN (40 sider) i kategorien Alarmsystem. Denne vejledning er vurderet som hjælpsom af 11 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 6 anmeldelser. Har du et spørgsmål om DSC HS2ICN, eller vil du spørge andre brugere om produktet?

Side 1/40
English, Français, Español, Português
WARNING: Refer to the PowerSeries Neo Reference manual for information on limitations regarding product use and function, and information on the limitations as to the liability of the manufacturer.
NOTE: These instructions must be used in conjunction with the system installation manual of the control panel with which this equipment is intended to be used. This installation sheet applies to the fol-
lowing models: HS2LED, HS2ICN, HS2ICNP, HS2ICNRFx, HS2ICNRFPx, HS2LCD, HS2LCDP, HS2LCDRFx and HS2LCDRFPx; x = 9 where the system operates in 912-919MHz, 8 where the
system operates in 868MHz band, and 4 where the system operates in 433MHz band. The Model HS2LED, HS2LCD(P), HS2ICN(P), HS2LCDRF(P)8, HS2ICNRF(P)8 keypads have been certified by
Telefication according to EN50131-1:2006 + A1:2009, EN50131-3:2009 for Grade 2, Class II.
HS2LED/HS2ICN(P)(RF)x/HS2LCD(RF)(P)x v1.0
Installation Instructions, Instructions d’Installation, Instrucciones de instalación,
Instruções de Instalação
The HS2LED/HS2ICN(P)(RF)x/HS2LCD(RF)(P)x keypads are
compatible with the PowerSeries Neo HS2016/32/64, HS2014-
4* and HS2128 panels. The RF keypads combine a wireless
transceiver with the respective HS2 keypad.
* Model not UL/ULC listed.
Specifications
* Zone not to be programmed as Fire type or 24h type.
NOTE: Keypads contain no serviceable parts.
NOTE: Only models operating in band 912-919MHz are UL/
ULC listed.
Unpack
The keypad package includes the following:
Mount
Mount the keypad where it is accessible to designated points of
entry and exit. Once a dry and secure location is selected, per-
form the following steps to mount the keypad.
Disassemble Keypad
1. Insert the tip of a flat-head screwdriver into the slots at the
bottom left and right of the keypad.
2. Gently pry open the faceplate. This will remove it and allow
access for mounting.
Mount and Wire Keypad
1. Secure keypad to wall using mounting holes. Use all four
screws provided unless mounting on a single gang box. Use
the plastic anchors supplied if the unit is to be mounted on
drywall.
2. If using the keypad tamper, secure the tamper plate to the
wall with a screw.
NOTE: For UL/ULC listed commercial burglary installations,
the use of the keypad tamper is mandatory.
3. Run wire through wiring slot or knockouts. Connect Corbus
and PGM/Zone wiring to keypad. Place tamper switch into
tamper hole on backplate.
4. Place keypad into backplate, ensuring the wire is pushed
back into the wall as much as possible. Route the wire inside
the keypad, ensuring high components are avoided. Snap the
front assembly closed, ensuring that there is no pressure to
the keypad from the wire below.
Installation Instructions
Temperature range: -10°C to +55°C (14°F to 131°F); Tem-
perature range for UL/ULC:C to +49°C (32°F to 120°F)
Humidity (MAX): 93%R.H. non-condensing
Plastic enclosure protection degree: IP30, IK04
Voltage rating: 13.8VDC nominal (power provided by the
compatible control panel)
Connects to control panel Corbus via 4 wires
1 configurable zone input or PGM output*
HS2LED/ HS2ICN(P)/HS2LCD(P)/HS2ICNRF(P)/
HS2LCDRF(P) Current draw:55mA(min)/105mA(max)
Wall-mount tamper
5 programmable function keys
Ready (Green LED), Armed (Red LED), Trouble (Yellow
LED), AC (Green LED)
Dimensions (L x W x D): 168mm x 122mm x 20 mm
Weight: 260g
Low temperature sensor
Frequency: 433 MHz (HS2ICNRF4/HS2LCDRF4)
868 MHz (HS2ICNRF8/HS2LCDRF8)
912-919MHz (HS2ICNRF9/HS2LCDRF9)
Up to 128 wireless zones
HS2LED/ICN(RF)/
LCD(RF) HS2ICN(RF)P/LCD(RF)P
1 keypad 1 keypad
4 mounting screws 4 mounting screws
2 end-of-line resistors 2 end-of-line resistors
Keypad inner door
labels
Keypad inner door labels
1 tamper switch 1 tamper switch
Installation Instructions Installation Instructions
Mini Proximity (prox) tag
(MPT)
Table 1: Compatible Devices
Wireless PG smoke detector PGx926UL
Wireless PG smoke and heat detector PGx916UL
Wireless PG CO detector PGx913
Wireless PG PIR motion detector PGx904(P) UL
Wireless PG PIR + camera motion detector PGx934(P)UL
Wireless PG curtain motion detector PGx924UL
Wireless PG dual tech motion detector PGx984(P)
Wireless PG mirror motion detector PGx974(P) UL
Wireless PG outdoor motion detector PGx994UL
Wireless PG glass break detector PGx912
Wireless PG shock detector PGx935UL
Wireless PG flood detector PGx985UL
Wireless PG temperature detector (indoor) PGx905UL
Outdoor temperature probe (requires PGx905) PGTEMP-
PROBE
Wireless PG key PGx939UL
Wireless PG key PGx929UL
Wireless PG panic key PGx938UL
Wireless PG 2-button key PGx949 UL
Wireless PG indoor siren PGx901 UL
Wireless PG outdoor siren PGx911UL
Wireless PG repeater PGx920UL
Wireless PG door/window contact PGx975UL
Wireless PG door/window contact w/AUX PGx945 UL
NOTE: In this chart, x in the model number represents the
operating frequency of the device as follows: 9 (912-919 MHz),
8 (868MHz), 4 (433MHz).
NOTE: Only models operating in the band 912-919 MHz are
UL/ULC or cUL listed where indicated. Only UL approved
devices are to be used with UL/ULC listed systems.
wiring slot
knockout
tamper
mounting holes
mounting holes
latchlatch


Produkt Specifikationer

Mærke: DSC
Kategori: Alarmsystem
Model: HS2ICN

Har du brug for hjælp?

Hvis du har brug for hjælp til DSC HS2ICN stil et spørgsmål nedenfor, og andre brugere vil svare dig




Alarmsystem DSC Manualer

DSC

DSC HS2128 Manual

3 August 2024
DSC

DSC HS2ICN Manual

30 Juli 2024
DSC

DSC PTK5507 Manual

25 Juli 2024

Alarmsystem Manualer

Nyeste Alarmsystem Manualer