395823110a 3
SAFETY NOTICE
The authority having jurisdiction (such as municipal building department, fire
department, fire prevention bureau, etc.) should be consulted before installation to
determine the need to obtain a permit.
If your Efel Stove is not properly installed, a house fire may result. For your
safety, follow the installation directions. Contact local building or fire officials
about restrictions and installation requirements in your area.
ENSURE THAT THIS MANUAL REMAINS WITH THE APPLIANCE AND IS
PASSED ON TO THE USER AFTER INSTALLATION.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
WARNING:
Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to this manual for assistance or consult a
qualified (experienced) installer.
SPECIAL NOTE:
Crazing of Porcelain Enamel:
Porcelain enamel, when heated to high temperature, is subject to crazing. Crazing is
a normal occurrence when enamel is exposed to high temperatures. Your enamel
finish will not be harmed nor will the function of the stove be impaired.
SPECIAL NOTE:
A barometric damper is recommended for installations of stoves in areas that may
have high winds, which can affect the draft. The installation must be only in units
with a newly constructed chimney, free of creosote deposits. The barometric damper
is an automatic device designed to regulate the draft in a heating appliance, which in
turn, stabilizes the chimney temperatures, lessening the potential of over-firing. Do
not place the barometric damper greater than 24 inches (610 mm) above the unit.
Excessive draft will lead to poor control of the burning rate and possible over-firing of
the stove and damage to the cast iron firebox. Most barometric dampers are
calibrated in inches of water column and can be set to draft requirements of -.03 to -
.08 inches (-7.5 to -20 Pa). It is recommended that the barometric dampers to be set
between -.05 and -.06 inches.
THE RECOMMENDED DRAFT REQUIREMENTS FOR EFEL STOVES IS NO LESS
THAN -.04 AND NO GREATER THAN -.08.
OPERATION OF YOUR STOVE WITH A DRAFT GREATER THAN -.08 CAN
POSSIBLY CAUSE DAMAGE TO THE STOVE AND VOID THE WARRANTY.