CAUTION! IMPORTANT
This Instant Hot Shower is a single point
system and the “Water Outlet” can only be fitted
to the Hose and Handshower set
provided. MUST NO O CONNECT T T
CONTROL VALVE OR FITTING CAN BE
FITTED O THE WATER OUTLET. T
4.1 Connect the 3 in 1 Stop Valve to the Water
Inlet with washer. Use correct tools to tighten
and be careful not to over tighten and damage
the plastic nut.
4.2 Connect the incoming water piping to the
3 in 1 Stop Valve (1/2” BSP).
Make sure to put the Mesh Filter between 3
in 1 Stop Valve and incoming water piping.
4.3
If in any case, the 3 in 1 Stop Valve is not
use or omitted, make sure to put the Mesh
Filter between the Instant Hot Shower inlet
pipe and incoming water pipe.
4.4 Turn on the water mains to drain out all
plumbing dirts before connecting the water
supply to the Instant Hot Shower, the water
supply to the Instant Hot Shower must be free
from mud and dirt. Always KEEP
the water supply to the Instant Hot Shower free
from mud and dirt at all time during usage.
THE HEATER TANK MUST BE FILLED UP WITH
WATER BEFORE TURNING ON THE POWER
SUPPLY O PREVENT ANY DRY BURNT T
DAMAGE O THE HEATING ELEMENT. T
4.5 Connect the Hose and Handshower to
the outlet of Instant Hot Shower, be sure to put in
the Washer in between the connection. (Fig. 2)
4.6 Hook the Handshower to the Slider Rail
Shower Holder and adjust to your ideal position.
4.7 Check if any water leakage.
4.8 Do not use white tape during piping
installation.
4.9 THE WATER INLET AND OUTLET MUST BE
INSTALLED CORRECTLY, OTHERWISE
INSTANT HOT SHOWER WILL NOT FUNCTION.
4.10 DO NOT APPLY PLUMBING CEMENT ON
CONNECTION. WHENEVER NECESSARY, USE
ONLY THREAD OR SEALING TAPE.
WARNING!
Voltage Power Current
(AC) (kW) (A)
3.6 15.0 4.0 7 / 0.85mm 56 / 0.30 mm 20 20
240V ~
50/60 Hz
Conductor Size (csa)
mm Conduit Cable Flexible Cable
On/ Off Fuse /
Switch (A) MCB (A)
(Malaysia Model)
2
7. TEST RUN
7.1 Turn on the water supply and 3 in 1
Stop Valve, the water will flow through the
Handshower.
7.2 Switch on the power supply. The 2
LED Indicator light shall run ON/OFF 3
times in sequences to indicate the set are
self checking.
If the Instant Hot Shower is not earthed
properly, the Earth Led indicator light will
OFF, during usage or standby. Earth Led
indicator light also OFF if Live & Neutral
reverse connection.
7.3 Turn the Temperature Control Knob to
‘ON’, the Red indicator light (HEATER POWER)
will turn on, (ELCB/Power Led indication are
combine Led indicator light- ELCB is GREEN
& Power is RED) hot water will flow out within
a few seconds. The more Temperature Control
Knob being turned in clockwise direction, the
hotter is the water.
7.4 The Instant Hot Shower might not be hot
enough even at the ‘MAX’ position if incoming
water supply from the mains is too cold or the
pressure of water is too high. In this case, you
may adjust the 3 in 1 Stop Valve to reduce the
water inflow in order to get the desired
showering temperature. (Recommended flow
rate of below 6litre/min)
7.5 Check the Built-in ELCB as following:
- Press the “TEST” Button, the Built-in ELCB
should trip and cut off the power supply,
ELCB and Power Indicators should light off.
-Press the “RESET” Button, the 2 LED
Indicator light shall run ON/OFF 3 times in
sequences to indicate self checking as in 7.2
above and the Instant Hot Shower should
resume normal function, the Green LED
Indicator should light on. If procedures stated
above prevailed, the ELCB is functioning in
normal condition.
7.6 The height and direction of Shower
Holder are adjustable by releasing the shower
holder knob clockwise and anticlockwise.
7.7 Move the Handshower to the desired
angle. A ratchet mechanism in the Shower
Holder will hold the Handshower in selected
position.
7.8 It is unnecessary to turn the Temperature
Control Knob to “OFF” position when the
Instant Hot Shower is not in use.
7.9 Switch OFF the power supply after shower.
7.10 For Pump model:
The pump will auto ON when power ON and
3 in 1 stop valve open (and there is water supply)
7.11 Booster Pump Function:
After incoming power supply is ON, and water
supply flow through 3 in 1 stop valve while open
position but the water flow rate is not sufficient to
activate the flow sensor, Booster Pump Function
can be useful to help to increase the incoming water
flow rate. Press the pump button to activate the booster
pump function. The booster pump function will be ON to
increase the incoming water flow rate. While the Booster
Pump Function is working and the incoming water flow
rate can be maintained above flow sensor activation level,
the Electric Water Heater will be resumed working
continuously as normally. If the incoming flow rate can
not be maintained above flow sensor activation level,
the Booster Pump Function will be auto OFF and the
Electric Water Heater will not be able to function normally
due to incoming flow rate is too low. (Advisable to avoid
applying Booster Pump Function to increase the incoming
water flow rate more than 3 times of each showering).
8. HANDSHOWER SPRAY
9. MAINTENANCE
Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
Fig. 8 Fig. 9
FILTER UNIT CLEANING
CLOSEOPEN
INTERNAL
STRAINER
OPEN CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
This Innovative adjustable Handshower has 5 different spray patterns (STANDARD, JUMBO, SOOTHE, MIX
and MASSAGE. The patterns are described as following:
Fig. 7
STANDARD SPRAY SOOTHE SPRAY JUMBO SPRAY MIX SPRAY MASSAGE SPRAY
9.1 TEST THE ‘ELCB’ REGULARLY
(This procedure is highly recommended test at
least once a month)
Turn on the power supply and water supply, both
Red (HEATER) and Green (ELCB) Indicators will
light up if the Temperature Control Knob is in ‘ON’
position. Press the ELCB Test Button, both
HEATER and ELCB Indicators should go off.
Press the Reset Button to resume the power
supply.
9.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent
blockage (Fig. 8) . Remove the Built-in Filter by
turning its cap anticlockwise. Whenever need
flush the internal stainer with water to remove any
trapped sediments. Whenever fixing back the
Built-In Filter, beware of the alignment of Internal
Strainer. Use the protruded guideline within Stop
Valve to position the Internal Strainer.
Read the section ‘ SAFETY INFORMATION ’ first. WARNING!
9.3 If the HEATER Indicator does not go off
when you press the ELCB Test Button, switch
OFF the mains supply and contact Electrolux
Consumer Care Centre for repair service.
Special skill is required for repairing. NEVER
try to repair the unit by yourself.
9.4 CLEANING PRECAUTION !
Do not use thinner,alcohol,petrol or any other
organic solutions to clean the set. Use only
damped cloth with mild detergent.
10. WIRING DIAGRAM
* Manual Reset (90° C Thermostat)Thermostat
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced
ce permanently tripped.
WIRING DIAGRAM -WITH ELCB, AC PUMP DPDT MODEL
LIVE
NEUTRAL
TRIAC
Relay 1 Lout
Relay 2 Nout
(N
in
)
(L
in
)
Auto-Reset * Ma nua l-Reset
Power Supply
220/230/240 V~a.c.
Double A ction Th ermostat
T2
G
Electronic
ELCB,15mA
Sensiti vity
Reset
Test
Heater Control
On/Off Switch
Power On/Off
Temperature Control
Pump M otor
PUM P
WIRING DIAGRAM -WITH ELCB, DC PUMP DPDT MODEL
LIVE
NEUTRAL
TRIAC
Relay 1 Lout
Relay 2 Nout (N
in
)
(L
in
)
Auto-Reset * Ma nua l-Reset
Power Supply
220/230/240 V~a.c.
Double A ction Th ermostat
T2
G
Electronic
ELCB,15mA
Sensiti vity
Reset
Test
Heater Control
On/Off Switch
Power On/Off
Temperature Control
SMPS PCB
ASSY
Silent Pump
WIRING DIAGRAM -WITH ELCB, NO PUMP DPDT MODEL
LIVE
NEUTRAL
Power On/Off
Temperature Control
TRIAC
Lout
Nout
(N
in
)
(L
in
)
Auto-Reset * Ma nua l-Reset
Power Supply
220/230/240 V~a.c.
Double A ction Th ermostat
Electronic
ELCB,15mA
Sensiti vity
Reset
Test
T2
G
Heater Control
On/Off Switch
Rela y 1
Rela y 2
Pump Button
Pump Button
on
11.
ELECTRICAL SPECIFICATION
Note : The specification, actual product’s cosmetic design and accessories parts shown are
correct at the time of printing and may be subjected to change without prior notice.
2.5 kg - ELCB , DPDT , AC PUMP
2 Litre / min
ELECTRONIC POWER CONTROLTYPE
ELECTRICAL LOADING
Min. WATER FLOW RATE
WATER CONNECTION
DIMENSIONS
NET WEIGHT
3.6kW 240Va.c. 50/60Hz
1/2” BSP SINGLE POINT SYSTEM
220 (W) X 401 (H) X 90 (T) mm
6.0 Bar (0.6 MPa ; 87.02 psi)
Max. INLET WATER PRESSURE
Min. INLET WATER PRESSURE
0.1 Bar (10 kPa ; 1.45 psi)
2.0 kg - ELCB , DPDT , DC PUMP
1.5 kg - ELCB , DPDT , NO PUMP
CONSUMER CARE
Indonesia
Hotline service: 08041119999
PT. Electrolux Indonesia
Electrolux Building
Jl.Abdul Muis No.34, Petojo Selatan,
Gambir Jakarta Pusat 10160
Email:customercare@electrolux.co.id
SMS & WA : 0812.8088.8863
Malaysia
Consumer Care Center Tel: 1300-88-11-22
Electrolux Home Appliances Sdn. Bhd.
Corporate Office Address: Unit T2-7, 7th Floor, Tower 2 ,
Jaya33 Hyperoffice, No. 3, Jalan Semangat, Seksyen 13,
46100 Petaling Jaya, Selangor
Office Tel : (+60 3) 7843 5999
Office Fax : (+60 3) 7955 5511
Consumer Care Center Address: Lot C6, No. 28,
Jalan 15/22, Taman Perindustrain Tiong Nam,
40200 Shah Alam, Selangor
Consumer Care Center Fax : (+60 3) 5524 2521
Email : malaysia.customercare@electrolux.com
Philippines
Consumer Care Center Toll Free : 1-800-10-845-CARE 2273
Consumer Care Hotline : (+63 2) 845 CARE 2273
Electrolux Philippines, Inc.
10th Floor. W5th Avenue Building
5th Avenue Corner 32nd Street
Bonifacio Global City,
Taguig Philippines 1634
Trunkline: +63 2 737- 4756
Website : www.electrolux.com.ph
Email : wecare@electrolux.com
Singapore
Consumer Care Center Tel: (+65) 6727 3699
Electrolux S.E.A. Pte Ltd.
1 Fusionopolis Place,
#07-10 Galaxis, West Lobby
Singapore 138522.
Office Fax : (+65) 6727 3611
Email : customer-care.sin@electrolux.com
Thailand
Consumer Care Tel : (+66 2) 725 9000
Electrolux Thailand Co., Ltd.
Electrolux Building 14th Floor
1910 New Phetchaburi Road,
Bangkapi, Huai Khwang, Bangkok 10310
Office Tel : (+66 2) 7259100
Office Fax : (+66 2) 7259299
Email : customercarethai@electrolux.com
Vietnam
Consumer Care Center Toll Free : 1800-58-88-99
Tel : (+84 8) 3910 5465
Electrolux Vietnam Ltd.
Floor 9th, A&B Tower
76 Le Lai street - Ben Thanh Ward - District 1
Ho Chi Minh City ,Vietnam
Office Tel : (+84 8) 3910 5465
Office Fax : (+84 8) 3910 5470
Email : vncare@electrolux.com
Hongkong
Tel: (+852) 8203 0298
Dah Chong Hong, Ltd. - Service Centre
8/F., Yee Lim Godown Block C
2-28 Kwai Lok Street, Kwai Chung, N.T.
WARNING! PROCEDURE :
5.6 ns I er het t wall embedded cable through
S nt ‘A’ u a a ce ide E ry by c tting hole t the sour
cord rubber holder and lead he able Cable t c to
B c ‘B’ (F 6)ra ket . ig.
5.7 : cConnec het t able as following
BR N RED )OW or --LIVE (L
B LAC EUTRAL )LUE or B K --N (N
GR N R N RTH ( )EE or G EE /YELL --EAOW
5.8 o sit . tClamp he cable t the correct po ion
CH G NN TIOEC H RINK IF T E WI CO EC N IS
CO EC ce .RR T and repla t che over
5.9 , When putting bac hek t Front Cover
plea ake nose t te o hef t
pro edure shown belowc :
-Ens t i ure the posi ion s correc urnt, t the
T t t o empera ure Con rol K Inob nsert t OFF
posi ion hown in ig.A he Hea er aset as s F (At t t B )
-In t stall t F t The ront Cover,turn he empera ure
Con rol nob posi ion align wi het K to OFF t to th t
VR ( v ) shaft as shown in Fig.B At the Front Co er
5. i t 10 F x the Tempera ure Cont rol Knob and
sc ‘A’ (F .rew ig. 2)
Cable
Fig. 4
Brown or Red = Live (L)
Blue or Black = Neutral (N)
Green or Green/ Yellow = Earth ( )
Fig. 5
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
ON/OFF Double Pole Switch
Double PVC cable over 4.0mm
2
NOTE:
Refer to TABLE 1 for electrical loading and
correct size of wire conductor
METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER
Front CoverFig A Fig B
5.1 This appliance must be earthed.
Improper grounding could cause electrical
shock.
5.2 Remember to SWITCH OFF the power
supply before carrying out any electrical work.
5.3 Refer to TABLE 1 for the correct cable
size.
5.4 Use double insulation cable of over
4.0mm²
5.5 Lead the power cable from MCB to a
“ON/OFF’’ double pole Linked Switch
having a contact separation of at least 3mm
in all poles outside the bathroom, then lead
a cable to the terminal block inside the
Instant Hot Shower. (Fig. 4)
Position
this Way
A