EnerGenie EG-UPS-PS3000-01 Manual


Læs gratis den danske manual til EnerGenie EG-UPS-PS3000-01 (28 sider) i kategorien Uafbrydelig strømforsyning (UPS). Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 18 anmeldelser. Har du et spørgsmål om EnerGenie EG-UPS-PS3000-01, eller vil du spørge andre brugere om produktet?

Side 1/28
Line-interactive UPS
User Manual
~ 1 ~
Table of Contents
1 Safety Information .........................................................................................................................
2 Product Overview ............................................................................................................................ 4
2.1 Specifications 4..................................................................................................................................
2.2 Front panel features ....................................................................................................................... 7
2.2.1 Tower panel 7.................................................................................................................................................................
2.2.2 SRT panel 7....................................................................................................................................................................
2.3 Rear panel features 7.......................................................................................................................
2.3.1 Tower rear panel 7.........................................................................................................................................................
2.3.2 SRT rear panel 8............................................................................................................................................................
3 Installation........................................................................................................................................ 9
3.1 Unpacking inspection .................................................................................................................... 9
3.2 Installation information .................................................................................................................. 9
3.2.1 Safety precautions 9......................................................................................................................................................
3.2.2 Tower installation 10......................................................................................................................................................
3.2.3 Long backup model UPS installation 12......................................................................................................................
3.2.4 SRT installation 13.........................................................................................................................................................
4 Operation 15........................................................................................................................................
4.1 Buttons operation 15.........................................................................................................................
4.2 LED Indicator light 16........................................................................................................................
4.3 LCD display interface 16..................................................................................................................
4.4 UPS On/Off operation 18.................................................................................................................
4.4.1 Turn on the UPS 18........................................................................................................................................................
4.4.2 Turn off the UPS 19........................................................................................................................................................
4.5 Parameter query operation ......................................................................................................... 19
5 UPS Settings.................................................................................................................................. 21
6 Troubleshooting............................................................................................................................ 25
6.1 Fault messages 25............................................................................................................................
6.2 Common faults and processing ................................................................................................. 26
7 Maintenance 27...................................................................................................................................
7.1 Preventive maintenance ............................................................................................................. 27
7.2 Battery maintenance 27....................................................................................................................
Line-interactive UPS
User Manual
~~
1 Safety Information
Please charge the product for more than 8 hours before using.
When the battery has been discharged or the storage period has been more than 3 months,
the battery shall be charged for more than 8 hours in time, so as to ensure it is
fully-charged and prevent it from being damaged.
This product is specially designed for group computers. It shall not be connected with
inductive loads (e.g. motor, refrigerator, etc.). It is not recommended for life supporting
system and other specific major equipments;
Keep a distance of at least 50 cm from the display during installation of the product.
It’s normal for the surface temperature of the cabinet may rise to 50 during use of the
product.
Do not overload the product.
Do not open the cabinet of the UPS due to hazard of electrical shock, Contact your local
service center if maintenance or repair is needed.
UPS inner short circuit will cause electric shock or fire danger. Do not put any liquid vessel
on the UPS.
Cut off the power supply rapidly if the UPS work abnormal, and contact your local dealer.
Make sure not to keep or use the product in following environment.
No good air circulation
Place having flammable gas or corrosive material or lots of dust
Place under abnormal high or low temperature (above 40 or below 0 ), or high℃ ℃
humidity (above 90%)
Place where there is direct sunlight or near the heating appliance
Place where there is violent vibration
Outdoor
Do not use liquid extinguisher if there is a fire, a dry powder extinguisher is recommended.
Place the UPS near the mains source so that can cut off utility power without any delay in
case of emergency.
When the UPS is to be moved or reconnected, ensure that the AC input power supply is
cut off and the UPS is completely turned off, otherwise the output end may be electrified
and result in electric shock.
The battery life is shortened as the ambient temperature rises. Periodic battery
replacement can ensure UPS working properly and enough backup time.
The battery maintenance shall only be carried out by the personnel having professional
knowledge of batteries.


Produkt Specifikationer

Mærke: EnerGenie
Kategori: Uafbrydelig strømforsyning (UPS)
Model: EG-UPS-PS3000-01
Bredde: 467 mm
Dybde: 190 mm
Højde: 336 mm
Vægt: 28100 g
Brugervejledning: Ja
Produktfarve: Sort
Batterispænding: 12 V
Batterikapacitet: 9 At
Skærmtype: LED
USB-port: Ja
Batteriteknologi: Blybatterier (VRLA)
Formfaktor: Tower
Responstid: 10 ms
Relativ luftfugtighed ved drift (H-H): 10 - 90 %
Driftstemperatur (T-T): 0 - 40 °C
Støjniveau: 50 dB
Udgangseffekt: 220 W
Opladningstid for batteri: 12 t
Indgangsfrekvens: 50/60 Hz
Lydalarmer: Ja
Strømbeskyttelsesfunktioner: Overload,Short circuit
Strømstik: C14 forbinder
AC udgange, antal: 6 AC stikkontakt(er)
AC stikkontakt typer: C13 forbinder
Indgående driftsspænding (maks.): - V
Output strømkapacitet (VA): 3 kVA
Indgående driftsspænding (min.): 220 V
Udgangs driftsspænding (min.): 220 V
Udgangs driftsspænding (maks.): - V
Bølgeform: Sine
Typisk backup tid ved halv styrke: 30 min.
Typisk backup tid ved fuld styrke: 10 min.
Automatisk spændingsregulering (AVR): Ja
Uddgående frekvens: 50/60 Hz
Batteri bredde: 151 mm
Opladningsstrøm: 1.7 A
Batteri dybde: 65 mm
Batteri højde: 94 mm

Har du brug for hjælp?

Hvis du har brug for hjælp til EnerGenie EG-UPS-PS3000-01 stil et spørgsmål nedenfor, og andre brugere vil svare dig