Everpure EZ-RO 650 Manual


Læs gratis den danske manual til Everpure EZ-RO 650 (28 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 5 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 3 anmeldelser. Har du et spørgsmål om Everpure EZ-RO 650, eller vil du spørge andre brugere om produktet?

Side 1/28
EZ-RO SYSTEMS
INSTALLATION & OPERATION GUIDE
For Reverse Osmosis Systems
with Blending & Atmospheric Tanks
foodservice.pentair.com
2 | PENTAIR EZ-RO INSTALLATION AND OPERATION GUIDE FOODSERVICE.PENTAIR.COM
SAFETY INSTRUCTIONS
NOTES
The appliance is only to be installed in locations
where its use and maintenance are restricted to
trained personnel.
Children should be supervised to ensure that they do
not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
The appliance is not suitable for installation in an area
where a water jet could be used.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualied persons in order to avoid a hazard.
Substances listed as reduced are not necessarily in
your water. System must be maintained according to
manufacturers instructions, including replacement of
lter cartridges.
Your water must be within required inuent water
characteristic limits for satisfactory operation. If not,
the reverse osmosis (RO) membrane cartridge’s life
may be shortened and your warranty will be voided
(see Installation Requirements).
Install on cold water line only. Tempered water up to
80°F (26.7°C) can be used.
Do not install where system will be exposed to direct
sunlight.
Make certain that installation complies with all
state and local laws and regulations. Only use PTFE
thread seal tape or plumbers tape without adhesive
backing to seal joints. Do not use pipe compound
(“pipe dope”), sticks, or similar compounds with
this unit; they contain petroleum derivatives which
can cause crazing and cracking of the plastic in the
filter housing.
WARNINGS
Installation shall comply with applicable local, state,
and national plumbing and electrical regulations.
This appliance must be grounded. This appliance is
equipped with a cord having an appliance-grounding
conductor and a grounding plug. The plug must be
plugged into an appropriate outlet that is installed
and grounded in accordance with all local codes and
ordinances. If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent or
similarly qualied persons in order to avoid a hazard.
Improper connection of the appliance-grounding
conductor can result in a risk of electric shock. Check
with a qualied electrician or service representative
if you are in doubt whether the appliance is properly
grounded. Do not modify the plug provided with the
appliance; if it will not t in the outlet, have a proper
outlet installed by a qualied technician.
The appliance is intended to be permanently
connected to the water mains and not connected by
a hose-set.
Before installing the system, make certain your
water supply complies with the following operating
specications. Failure to do so may reduce the
effectiveness of the system and will void the warranty.
Consult your local water treatment utility or a
certied water testing lab to determine the quality of
your water.
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system. The Pentair EZ-RO System
will not protect against disease-causing bacteria or
remove naturally occurring harmless bacteria.
The EZ-RO System contains replaceable components
that are critical to the eciency of the system.
Replacement of the reverse osmosis component
should be with one of identical specications, as
dened by the manufacturer, to assure the same
eciency and contaminant reduction performance.
The EZ-RO System has lter cartridges and an RO
membrane cartridge included with the system that
have limited service lives which are critical for the
effective reduction of total dissolved solids. Product
water should be tested periodically to verify that the
system is working properly.
The power supply must be securely mounted in a dry
location, unlikely to get wet due to potential leaks or
splashes from the RO processor or the tank assembly.
CAUTIONS
The EZ-RO System must be protected against
freezing which can cause the lter housing to crack,
resulting in water leakage.
Do not use electrical heating tape or a propane torch
on this unit.


Produkt Specifikationer

Mærke: Everpure
Kategori: Ikke kategoriseret
Model: EZ-RO 650

Har du brug for hjælp?

Hvis du har brug for hjælp til Everpure EZ-RO 650 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Everpure Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Watson

Watson B-4246 Manual

25 August 2025
Vestil

Vestil BOL-42-2 Manual

25 August 2025
Vestil

Vestil P-HOP-1.5 Manual

25 August 2025
ATen

ATen CE980 Manual

25 August 2025
Wesco

Wesco 272941 Manual

25 August 2025
DeWalt

DeWalt DXV53S Manual

25 August 2025