Læs gratis den danske manual til Extech CO100 (3 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 18 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 9.5 anmeldelser. Har du et spørgsmål om Extech CO100, eller vil du spørge andre brugere om produktet?

Side 1/3
User's Guide
Desktop Indoor Air Quality Monitor
Model CO100
2 CO100-EU-EN-V2.0-11/11
Introduction
Congratulations on your purchase of this Extech Meter. The Carbon Dioxide (CO
2
) Monitor is designed
for air quality control and health control by measuring Carbon Dioxide level in areas where CO
2
could
be a concern. The measured CO
2
value in ppm (parts-per-million), Temperature, Humidity and Time
will be displayed on the LCD along with three CO
2
status indications: Good (0 to 800ppm), Normal
(800 to1200ppm), Poor (>1200ppm). An acoustic alarm sounds when the CO
2
level exceeds a dened
level. This meter is shipped fully tested and calibrated and, with proper use, will provide years of
reliable service.
Operation
1. Power button (rear)
Turns the unit on or o.
2. (rear) HOLD button
Freezes the current reading in the display.
3. (rear) °C/°F button
Selects °C or °F
4. (rear) Clock button
Press and hold this button for 2 seconds to
enter into clock mode. Press the ” or “▲ ▼
button to adjust the ashing digits. Press the
clock button again to step through the
settings (day:month:year;hour:minute).
Press the “ESC” button to exit the clock setting mode.
5. Alarm button
Press the Alarm button once to activate the Alarm mode. The icon appears on LCD
display. If the measured value exceeds the dened value, the alarm will sound and the
display will ash. Press the button again to exit the Alarm mode.
Alarm Value Setting
Press and hold the ALARM button for 2 seconds to enter into setting mode. The icon
will ash.
Press the or ▲ ▼ button to increase or decrease the value.
Press the ESC button to exit the setting mode.
“GOOD-NORMAL” and “NORMAL-POOR” Value Setting
In the Alarm Value Setting mode, press the ALARM button to set the GOOD NORMAL
threshold value. “GOOD NORMAL” will appear in the display. Adjust the value as needed.
Press the ALARM button again to set the NORMAL POOR threshold value. “NORMAL
POOR” will appear in the display. Adjust the value as needed.
Press the ESC button to exit the mode.
6. button
Press this button to increase a value. Press the “ESC” button to exit the function.
7. button
Press this button to decrease a value. Press the ESC button to exit the function.
8. MAX MIN button
Press the button once, the ”MAX” icon appears and the Maximum measured value of
CO2, temperature and humidity will be displayed on the screen. The display will be
updated only if a higher value is measured. Press this button again, the ”MIN” icon
appears and the Minimum measured value of CO2 temperature and humidity will be
displayed on the screen. Press ESC button to exit the function.


Produkt Specifikationer

Mærke: Extech
Kategori: Ikke kategoriseret
Model: CO100

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech CO100 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Extech Manualer

Extech

Extech 380580 Manual

22 Oktober 2024
Extech

Extech CO220 Manual

27 September 2024
Extech

Extech MO57 Manual

18 September 2024
Extech

Extech HD750 Manual

13 September 2024
Extech

Extech 380396 Manual

1 September 2024
Extech

Extech HDV600 Manual

1 September 2024
Extech

Extech 380395 Manual

1 September 2024
Extech

Extech HDV540 Manual

28 August 2024
Extech

Extech 380260 Manual

28 August 2024
Extech

Extech CO100 Manual

11 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer