Extech DV23 Manual


Læs gratis den danske manual til Extech DV23 (1 sider) i kategorien Måling. Denne vejledning er vurderet som hjælpsom af 4 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 2.5 anmeldelser. Har du et spørgsmål om Extech DV23, eller vil du spørge andre brugere om produktet?

Side 1/1
DV23enUS_V1.02/15
1
2
3
4
USERGUIDE
DV23 Non Contact VoltageDetector
Safety
Detectoron operation a known livecircuittoverifyproper
WARNING:RiskofElectrocution.Keephandsandfingersonthe
bodyoftheprobeandawayfromtheprobetipandtestedinductor
CAUTION:Read,understandandfollowSafety
RulesandOperating
Instructionsinthismanualbeforeusingthisproduct.
Do not attempt repairs. There are no user serviceable parts.
Do not expose unit to extreme temperatures or high humidity
Do not use the unit if it is wet or damaged
Do not apply more than
the rated voltage between the probe tip
andground.
Do not operatewiththecaseopen.
Thissymbol,adjacent symboltoanother orterminal,
indicatesthe the theuser usermustreferto manualfor
furtherinformation.
Thissymbol,adjacentto a terminal,indicatesthat,under
normaluse,hazardousvoltagesmaybe present.
Doubleinsulationsymbol
Specifications
VoltageSensitivity50V to 600V AC
Bandwidth 50/60Hz
Detectiondistance<0.2”
OperatingTemperature32 to 104
o
F(0to40
o
C)
StorageTemperature 14 to 122
o
F ( 10to50
o
C)
Altitude <7000’ (2000m)
RelativeHumidity < 95% RH
Batteries 2 x 1.5 ‘AAA’ type
Dimensions/Weight 6.25x1” (159x25mm) / 1.5oz (42g)
SafetyThis unit complies with:
EMC:EN613261:2006
LVD:EN61010 1:2010, EN61010 031:2002+1:2008
UL:UL610101,2
nd
Edition, 2005 07 22
CAN/CSAC22.2No.61010 1, 2
nd
edition, 2004 07
Forindooruseandinaccordancewith Overvoltage CategoryIV
600V,PollutionDegree2;conformstoCEstandards
ULListedThe UL mark does not indicatethatthisproducthas
beenevaluatedfortheaccuracyofitsreadings.
1. Pocketclip
2. Batterycompartment
3. Probetip
4. Detectorconelamp
OperatingInstructions
Note:Fornewmeters, andremovethebatteryendcap thenremove
thebattery insulating strip(ifnecessary).
ACVOLTAGEDETECTION
1. the Touch probe conductortip(3)tothehot orinsertintothe
hotsideoftheelectricaloutlet.
2. the IfACvoltage is present, detector cone will
illuminate(4)and
themeterwillbeep.
NOTE:Theconductorsinelectricalcordsetsareoftentwisted.For
bestresults,rubtheprobetipalong a lengthofthecordtoassure
gettingthe thetipincloseproximityto liveconductor.
NOTE:Thedetectorisdesignedwithhigh
sensitivity.Staticelectricity
orothersourcesofenergymay randomly trip the sensor.Thisis
normaloperation.
BATTERYINSTALLATION
1. the Remove endcap(2)bygentlytwisting.
2. InserttwoAAAbatteries(observepolarity).
3. the Replace endcap.
NOTE:Ifthemeterdoesnotworkproperly,check
the thatbatteriestoensure they’refreshand
properlyinserted.
CLEANING
Pleasewipethemeterwith cloth Do a damp asneeded. notuse
solventsorabrasiveswhen cleaning.
Warranty
FLIRSystems,Inc.warrantsthisExtechInstrumentsbranddevice to be free of defects in parts and workmanship
for oneyear fromdate andof appliesshipment(asixmonthlimitedwarranty tosensors cables).Ifitshould
becomenecessary to return the instrument for service during or beyond the warranty
period, contact the
CustomerServiceDepartmentforauthorization.Visit the website www.extech.com for contact information. A
ReturnAuthorization(RA)numbermustbe before anyissued productis isreturned.Thesender responsiblefor
shippingcharges, insurance and damage doesfreight, properpackagingtoprevent intransit.Thiswarranty not
apply
todefectsresultingfromactionof ofthe misuse,user assuch improperwiring,operationoutside
specification,impropermaintenanceorrepair,orunauthorizedmodification.FLIRSystems,Inc.specifically
disclaims specificanyimpliedwarrantiesor ormerchantability fitnessfor apurpose and be any willnot liablefor
direct,indirect,incidentalor
consequential damages. FLIR’s total liability is limited to repair or replacement of the
product.Thewarrantysetforthaboveisinclusiveand no otherwarranty,whetherwrittenororal, orisexpressed
implied.
Calibration,Repair,andCustomerCareServices
FLIRSystems,Inc.offersrepairandcalibrationservicesfortheExtech
Instrumentsproductswesell.NISTcertificationformostproductsisalso
provided.CalltheCustomerServiceDepartmentforinformationon
calibrationservices available for this product. Annual calibrationsshouldbe
performedtoverifymeterperformanceandaccuracy.Technicalsupportand
generalcustomerserviceisalsoprovided,refertothecontactinformation
providedbelow.
Copyright ©2015FLIRSystems,Inc.
Allrights rightreservedincludingthe ofreproductionin inwholeorinpart anyform
www.extech.com
Support Lines: U.S.(877)439 8324; International:+1 (603) 324 7800
TechnicalSupport: mail: support@extech.comOption3;E
Repair Returns: &Option4;Email:repair@extech.com
Productspecificationsare subject tochangewithoutnotice
Pleasevisitourwebsiteforthemostuptodateinformation
www.extech.com
FLIRCommercialSystems,Inc., 9
TownsendWest,Nashua,NH03063
ISO9001Certified


Produkt Specifikationer

Mærke: Extech
Kategori: Måling
Model: DV23

Har du brug for hjælp?

Hvis du har brug for hjælp til Extech DV23 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Måling Extech Manualer

Extech

Extech IR201A Manual

28 November 2025
Extech

Extech DV23 Manual

28 November 2025
Extech

Extech RHT10 Manual

28 November 2025
Extech

Extech DA50 Manual

28 November 2025
Extech

Extech 480836 Manual

28 November 2025
Extech

Extech MA3110 Manual

28 November 2025
Extech

Extech EA25 Manual

28 November 2025
Extech

Extech MA150 Manual

28 November 2025
Extech

Extech EA20 Manual

28 November 2025
Extech

Extech CA250 Manual

28 November 2025

Måling Manualer

Nyeste Måling Manualer

FLIR

FLIR E75 Manual

28 November 2025
Terraillon

Terraillon COACH Manual

27 November 2025
FLIR

FLIR T530 Manual

27 November 2025
FLIR

FLIR TG268 Manual

27 November 2025
Testo

Testo 558s Manual

26 November 2025
Eastron

Eastron SEM1 Manual

25 November 2025
Vevor

Vevor SC256M Manual

25 November 2025
Vevor

Vevor SD304 Manual

25 November 2025