Fantini Cosmi ZTTSE Manual


Læs gratis den danske manual til Fantini Cosmi ZTTSE (2 sider) i kategorien Temperaturregulator. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Fantini Cosmi ZTTSE, eller vil du spørge andre brugere om produktet?

Side 1/2
104
ZTTSE
Manual thermostatic head with external sensor
The thermostatic valve automatically regulates the flow of hot water in the radiators according to the room temperature set on the
control knob. The use of the valve with thermostatic head and external sensor allows the requirements of thermal comfort to meet
the needs of the user, even when the radiator is in a point where the heat tends to accumulate such as, for example, behind curtains,
behind furniture, under shelves, or where solar radiations directly cover the valve.
Temperature
scale
Antifreeze
position
External
sensor cable
length
Sensitive element
ZTTSE 8.5 ÷ 28°C 6°C 2 m with liquid
C Ø
M30x1,5
A
B
116
L 2 m
Antifreeze position (*)
A [mm] B [mm] C [mm]
81 74 46
Open position (5)
A [mm] B [mm] C [mm]
86 79 47
Dimensions (mm)
CHARACTERISTCS
Polycarbonate body.
Thermostatic ethyl acetate bulb liquid.
Remote sensor, with gas expansion.
Sensor’s cable length: 2m.
Adjustment range (1÷5): 8.5 ÷ 28°C
Antifreeze position (*): 6°C
Hysteresis: 0.6°C
Position (3): 20°C
Max differential pressure (with thermostatic head mounted): 100 KPa.
Response time: 20 min (low thermal inertia).
105
C
INSTALLATION
Horizontal installation to allow better heat exchange with the
ambient.
Vertical installation does not allow the valve to work properly.
For the thermostatic head with remote sensor, the probe has
to be placed away from heat sources that could impair proper
operation.
HOMOLOGATION AND STANDARDS
Compliant with the requirements of Italian MD dated 19 February 2007 (tax deductions).
OPERATION
If the heating element is in a point where the heat tends to accumulate such as, for example, behind curtains, behind furniture, under
shelves, or where solar radiations directly cover the valve, the thermostatic head has to be used with a remote sensor. This allows
you to put the sensitive element in a place most suitable for proper room temperature reading.
Adjust by turning the numbered knob so that the symbol corresponding to
the desired temperature is positioned in the reference window.
To protect proper operation of the thermostatic head, we recommend you remove it from the valve during the summer period when
the heating system is idle.
TEMPERATURE LIMIT
When the temperature has been adjusted, we recommend you
block the knob or limit the operation range.
8.5 ÷ 28°C
YES