FERM CRM1004 FC-700 Manual

FERM Kompressorer CRM1004 FC-700

Læs gratis den danske manual til FERM CRM1004 FC-700 (10 sider) i kategorien Kompressorer. Denne vejledning er vurderet som hjælpsom af 24 personer og har en gennemsnitlig bedømmelse på 4.4 stjerner ud af 12.5 anmeldelser. Har du et spørgsmål om FERM CRM1004 FC-700, eller vil du spørge andre brugere om produktet?

Side 1/10
Ferm B.V. P.O. Box 134 8280 AC Genemuiden • NL www.ferm.com 0208/27
Ferm FC-700
Oilless compressor
Ölfreier Kompressor
Olievrije compressor
Compresseur sans huile
Compresor libre de aceite
Oljefri kompressor
Itsevoiteleva kompressori
Oljefri kompressor
Oliefri kompressor
äÓÏÔÂÒÒÓ ÔÓ¯ÌÂ‚Ó„Ó ÚËÔ‡
USERS MANUAL
GEBRAUCHSANWEISUNG
GEBRUIKSAANWIJZING
MODE D’EMPLOI
MODEO DE EMPLEO
BRUKSANVISNING
KÄYTTÖOHJE
BRUKSANVISNING
BRUGER VEJLEDNING
êìäéÇéÑëíÇé èé ùäëèãìÄíÄñàà
Art.nr. 231700
2Ferm
Product: Ferm Oilless compressor
Type FC-700, Art. nr. 231700
Ferm, Genemuiden, The Netherlands
1. TECHNICAL DATA
This is a directly linked 1-cylinder compressor in mobile
design. This oil-free compressor is also equipped with a
reducing valve, a automatic shutdown and a quick coup-
ling.
Sound pressure level 83,8 dB(A)
CAREFULLY READ THE INSTRUCTIONS
BEFORE YOU USE THE COMPRESSOR!
2. SPECIFIC SAFETY RULES
BEFORE USING THE COMPRESSOR:
1. Place the compressor in a well ventilated, frost
free area.
To obtain sufficient ventilation and cooling the distan-
ce between the shield and the wall needs to be at least
50 to 60 cm.
2. The following points need to be checked:
- do the voltage of the engine and the engine safe
guard, if any, correspond to the mains voltage (ap-
pliances for a mains voltage of 230 V can be connec-
ted to a mains voltage of 220 V without any pro-
blems);
- an earthed mains connection (wall socket) needs
to be used;
- are the mains lead and the mains plug in a good con-
dition: solid, without any loose ends or damage;
- the pressure reducing valve may not be copletely
closed so as to prevent damage to membranes;
- before use the air tank needs to be empty.
IMPORTANT: To prevent damage to the motor
windings as a result of voltage variation it is advisable
to mount an engine safety switch.
WHILE USING THE COMPRESSOR:
1. Do not use extension cables which are too long.
IMMEDIATELY SWITCH OFF THE COMPRES-
SOR IN CASE OF:
1. defective mains plug, mains line or damage to the
mains line;
2. defective switch;
3. smoke or bad smell caused by scorched insulation.
3. INSTALLATION
The compressor needs to be placed in well-ventilated,
frost-free area. To obtain sufficient ventilation and coo-
ling the distance between the shield and the wall needs to
be at least 50 to 60 cm.
4. OPERATING THE COMPRESSOR
- The mains switch needs to be in “OFFor “0” posi-
tion before the mains plug is connected to the mains
voltage.
- Bij switching the switch to “ON” or “1” the compres-
sor will operate.
- Always keep the mains lead away from moving parts
of any linked up air-pressure equipment.
- With the use of the reducing valve it is possible to ad-
just the air pressure by hand. By pressing the reducing
valve the chosen position can be locked.
5. MAINTENANCE
The mains plug always needs to be taken out
of the socket (the mains socket) during main-
tenance or cleaning activities. Never use wa-
ter or other agressive liquids to clean the ma-
chine. Clean the machine by brushing it with
a brush.
PERIODIC MAINTENANCE OF THE COMPRES-
SOR WILL PREVENT UNNECESSARY PROBLEMS!
Every month:
Clean the air filter.
Every 1,000 working hours:
Carefully clean the outside of both the compressor
and the engine, to ensure an efficient cooling.
Condensation :
Regularly, i.e. several times a week, drain condensa-
tion from the air chamber, using the drain cock situa-
ted on the underneath of the air chamber.
!
UK English
Ferm 19
Art.
nr. Type
V~/Hz W RPM LTR. L/MIN BAR
231700 FC-700 230~50 1.100 2.800 25 200 7
1'
Exploded
view 2
FC-700
AVAILABLE SPARE PARTS FOR FC-700
REF.NR. DESCRIPTION FERM NR.
43 REAR COVER 208180
3 HEAD 208181
64 GASKET VALVE PLATE HEAD 208182
8223092 PISTON + CYLINDER COMPLETE 208183
62 GASKET 208185
8 CRANKSHAFT + AXLE 208186
23 FILTER 208187
49 COVER 208188
6 VALVE PLATE 208190
46-114 FAN 208191
80 CONDENSOR 25uF 208193
22 ROTOR 208194
24 STATOR 208195


Produkt Specifikationer

Mærke: FERM
Kategori: Kompressorer
Model: CRM1004 FC-700

Har du brug for hjælp?

Hvis du har brug for hjælp til FERM CRM1004 FC-700 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Kompressorer FERM Manualer

Kompressorer Manualer

Nyeste Kompressorer Manualer

Granit

Granit FL Manual

15 Januar 2025
Hamron

Hamron 604-193 Manual

13 Januar 2025
Güde

Güde 50079 Manual

12 Januar 2025
Bavaria

Bavaria BAC 180 Manual

11 Januar 2025
Zipper

Zipper ZI-COM 24 Manual

11 Oktober 2024
Gude Pro

Gude Pro 01730 Manual

26 August 2024
Gude Pro

Gude Pro 01732 Manual

26 August 2024