Translation of the original instructions
© 2021 all rights reserved to Festo SE & Co. KG
All available documents for the product
Only use the product in original status without unauthorised modifications.
The manifold blocks CPE...- PRS connect directional control valves to central
supply ports and are intended for wall or H-rail mounting.
The manifold block CPE...-PRSG-2/-3 (double or triple) connects type CPE 5/2- or
5/3-way valves to central supply ports.
Two additional valves can be supplied with the help of the extension plate CPE...-
The end plate CPE...-PRS-EP can be used to create different pressure zones or a
two-sided compressed-air supply.
The maximum configuration level is:
with one-sided compressed-air supply or
with two-sided compressed-air supply
The CPE-...-PRSO-... have the diaphragms removed.
1. Place all manifold blocks in their assembly sequence.
2. Trace the pressure curve, e.g. with a sketch.
When using multiple pressure zones:
• Make sure that the diaphragms at the interface of two pressure zones remain
Pressed-in diaphragms cannot be closed again. In doing so, consider
removing the diaphragms of the compressed air ducts for an unobstructed
Removing unused diaphragms:
Press in the 3 diaphragms of the compressed air ducts on the manifold block
from the outside inwards in accordance with the pressure curve sketch using
Deburr fracture margins and
This time-saving method of operation results in irregular broken edges compared
Place all manifold blocks on the H-rail in accordance with the assembly
Press the manifold blocks on the H-rail until the mounting slides engage.5
Place one sealing ring each between each of the three compressed air ducts
and press the manifold blocks together.
Push a connecting component onto the rail shown on both sides until it1
1. Insert all valve spools up to the first detent.2
Place a seal on every compressed air outlet.