Læs gratis den danske manual til Festo CPX-2ZE2DA (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 22 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 11.5 anmeldelser. Har du et spørgsmål om Festo CPX-2ZE2DA, eller vil du spørge andre brugere om produktet?

Side 1/2
CPX-2ZE2DA
input/output module
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Brief description
8101596
2018-11a
[8101598]
CPX-2ZE2DA input/output module English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For all available product documentation è www.festo.com/pk
1 Intended use
When used in combination with a CPX terminal, the CPX-2ZE2DA input/output
module enables
the processing, analysis and generation of pulses and measured values
the output of signals and voltages.
The module is intended for use in an industrial environment. Outside of industrial
environments, e.g. in commercial and mixed-residential areas, actions to suppress
interference may have to be taken.
The module is exclusively intended for use in CPX terminals from Festo and for
installation in machines or automated systems, and it may only be used as follows:
in perfect technical condition
in original status without unauthorised modifications, except for the adapta
tions described in this documentation
within the limits of the product defined by the technical data (è Chap. 9).
2 Safety
This documentation is directed exclusively at technicians trained in control and
automation technology.
Detailed information can be found in the module description
(è P.BE-CPX-2ZE2DA-...) as well as in the CPX system description
(è P.BE-CPX-SYS-...).
Warning
Electric shock
Injury to people, damage to the machine and system.
For the electrical power supply, use only PELV circuits in accordance with
IEC 60204-1 (Protective Extra-Low Voltage, PELV).
Observe the general requirements of IEC 60204-1 for PELV circuits.
Use only voltage sources which guarantee reliable electrical isolation of the
operating and load voltage in accordance with IEC 60204-1.
Always connect all circuits for operating and load voltage supplies U
EL/SEN
,
U
VAL
and U
OUT
.
Note
Electrostatic charge
Damage to the internal electronics.
Ensure assembly personnel are electrostatically discharged before
conducting any assembly work.
Note
Take into consideration the specifications and instructions in the module de
scription and the assembly instructions for the components.
Commission the module only if fully mounted and wired.
3 Transport and storage conditions
Protect the product during transport and storage from the following
mechanical loads
impermissible temperatures
moisture
aggressive atmospheres.
Only store and transport the product in its original packaging.
4 Connection and display components
1
2
3
4
5
6
7
8
aA
aB
9
aJ
aC
aD
aE
Status - inputs for channel 0
1Encoder input 1 (green)
2Encoder input 2 (green)
3Encoder input 3 (green)
4Digital input DI (green)
Status - inputs for channel 1
5Encoder input 1 (green)
6Encoder input 2 (green)
7Encoder input 3 (green)
8Digital input DI (green)
Status - outputs
9Digital output DO channel 0 (yellow)
aJ Digital output DO channel 1 (yellow)
Diagnostics
aA Module error (red)
aB Digital output DO channel 0 (red)
aC Digital output DO channel 1 (red)
aD Encoder supply 24 V (red)
aE Encoder supply 5 V (red)
Fig. 1
The assignment illustrated here may vary in individual operating modes.
For details regarding the operating modes, please refer to the module
description.
Fig. 2
Channel 0 Channel 1
Terminal Allocation Terminal Allocation
X1 .0 + X5 .0 +Encoder input 1 Encoder input 1
.1 .1
.2 + .2 +Encoder input 2 Encoder input 2
.3 .3
X2 .0 + X6 .0 +Encoder input 3 Encoder input 3
.1 .1
.2 Encoder supply 5 V
1)
+ .2 Encoder supply 5 V
1)
+
.3 .3
X3 .0 Encoder supply 24 V
1)
+ X7 .0 Encoder supply 24 V
1)
+
.1 .1
.2 Encoder supply 24 V
for DI
1)
+ .2 Encoder supply 24 V
for DI
1)
+
.3 .3Digital input DI Digital input DI
X4 .0 Reference potential for
encoder supply 24 V
for DI
X8 .0 Reference potential for
encoder supply 24 V
for DI
.1 .1Digital output DO Digital output DO
.2 .2Reference potential for DO Reference potential for DO
.3 Functional earth (FE) Functional earth (FE).3
1) Protected against short circuit and overload
Fig. 3


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: CPX-2ZE2DA

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo CPX-2ZE2DA stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

IFM

IFM E43416 Manual

2 Januar 2026
Pyle

Pyle PCRMP2DY Manual

2 Januar 2026
Testboy

Testboy TV 285 Manual

2 Januar 2026
Pioneer

Pioneer 2AM700 Manual

2 Januar 2026
Ruvati

Ruvati RVH7419 Manual

2 Januar 2026
Vaxcel

Vaxcel T0703 Manual

2 Januar 2026
Govee

Govee H1167 Manual

2 Januar 2026
Ruvati

Ruvati RVH9733 Manual

2 Januar 2026
Asus

Asus Prime AP202 Manual

2 Januar 2026