Læs gratis den danske manual til Festo CPX-E-CEC-M1 (7 sider) i kategorien DJ Gear. Denne vejledning er vurderet som hjælpsom af 38 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 19.5 anmeldelser. Har du et spørgsmål om Festo CPX-E-CEC-M1, eller vil du spørge andre brugere om produktet?

Side 1/7
CPX-E
Automation system
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instruction
8192618
2023-09b
[8192620]
8192618
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
IO-Link is a registered trademark of its respective trademark holder in certain
countries.
1 About this document
This document describes the use of the above-mentioned product family.
Certain aspects of use are described in other documents and must be observed
è1.1 Applicable documents.
1.1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
Document Content
Automation system CPX-E Manual Detailed description of the automation system
CPX-E
Operating instructions and manuals for the CPX-E
modules in the automation system CPX-E
Information on using the CPX-E modules
Tab. 1: Applicable documents
1.2 Product version
This document refers to the automation system CPX-E with CPX-E modules.
The product version can be identified from the product labelling or with the help
of appropriate software from Festo.
Software suitable for determining the product version is available from Festo in
the Support Portal èwww.festo.com/sp.
Information on using the software can be found in the integrated Help function.
1.3 Product labelling
The CPX-E modules are labelled on the left side. The product labelling is described
in the documentation supplied with the product.
1.4 Specified standards
Version
DIN46228-1:1992-08 EN60529:2013-10
DIN46228-4:1990-09 EN60715:2001-09
EN60068-2-27:2010-02 IEC60204-1:2014-10
Tab. 2: Standards specified in the document
1.5 UL certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL certification information
Product category code NRAQ/NRAQ7
File number E239998
Considered standards UL 61010-1, 3rd Edition, May 11, 2012, revised April 29, 2016
CAN/CSA-C22.2 No. 61010-1-12, 3rd Edition, Revision dated April
29, 2016
UL 61010-2-201, 1st Edition, Revised February 20, 2017
CSA-C22.2 No. 61010-2-201:14, 1st Edition, Issue date January 01,
2014
UL mark
Tab. 3: UL certification information
Technical data and environmental conditions may be subject to change in order
to comply with Underwriters Laboratories Inc. (UL) certification requirements
for the USA and Canada.
Note deviations Technical data.è
The unit shall be supplied by a power source which fulfils the requirements
on a limited-energy circuit in accordance to IEC/EN/UL/CSA 61010-1 or on
a Limited Power Source (LPS) in accordance to IEC/EN/UL/CSA 60950-1 or
IEC/EN/UL/CSA 62368-1 or a Class 2 circuit in accordance to NEC or CEC.
Unauthorised access to the device can cause damage or malfunctions.
When connecting the device to a network:
Protect the network against unauthorised access.
Measures to protect the network include:
• Firewall
Intrusion Prevention System (IPS)
Network segmentation
Virtual LAN (VLAN)
Virtual private Network (VPN)
Security at physical access level (port security)
For additional information Guidelines and standards for security in informationè
technology, e.g. IEC62443, ISO/IEC27001.
An access password only protects against unintentional modification.
NOTICE
Modules with Ethernet interfaces should only be operated in networks if all con-
nected network components are supplied by PELV circuits or integrated circuits
with equivalent protection.
2 Safety
2.1 Safety instructions
Take into consideration the legal regulations for the installation location.
Use the product only within the defined values
è13Technical data.
Observe the identifications on the product.
Observe further applicable documents.
Store the product in a cool, dry environment protected from UV and corrosion.
Keep storage times short.
Before working on the product: switch off the power supply and secure it
against being switched on again.
Comply with the handling specifications for electrostatically sensitive devices.
2.2 Intended use
The product described in this document is intended only for use within a pro-
tected range in the vicinity of a machine and/or automated system.
Use the product only as follows:
Use only in an industrial environment. Outside industrial environments, e.g.in
commercial and residential/mixed-use areas, it may be necessary to take meas-
ures to suppress radio interference.
Use only in combination with modules and components that are approved for
the applicable product variant èwww.festo.com/catalogue.
Only use the product if it is in perfect technical condition.
Only use the product in its original condition without unauthorised modifica-
tions. Only the conversions or modifications described in this and the further
applicable documents are permitted.
2.3 Training of qualified personnel
Work on the product should only be conducted by qualified personnel. The quali-
fied personnel must be familiar with installation of electrical control systems.
3 Additional information
Contact the regional Festo contact if you have technical problems
èwww.festo.com.
Accessories and spare parts èwww.festo.com/catalogue.
Firmware, software or configuration files èwww.festo.com/sp.
More information Content
Device description files Definition of the modules in an automation
system CPX-E for integration into the higher-level
controller
Documentation for the higher-order controller
and the additional devices in the network
Information on commissioning and parameterisa-
tion of the components
Tab. 4: More information
4 Product overview
4.1 Function
The Automation system CPX-E is a modular system for the connection of electrical
peripherals. The individual modules in an Automation system CPX-E are used,
forexample, to detect sensor signals and to control actuators. Using a bus
module or controller, the Automation system CPX-E can be connected to a higher-
order controller through a network or operated autonomously. Various interfaces
and functions are available for diagnostics.
4.2 Structure
4.2.1 Product design
4.2.1.1 Automation system CPX-E
The automation system CPX-E consists of a bus module or controller on the
left side and at least one I/O module for signal processing. The modules are
connected by linkage elements. The contacts of both external linkage elements
are protected by end supports.
2end supports are included with each bus module or controller.
1
2
3
Fig. 1: Structure of the automation system CPX-E (example)
1
Input and output modules
2
Linkage element
3
Bus module, here CPX-E-PN
4.2.1.2 CPX-E modules
The CPX-E modules are designed in such a way that it is possible to replace
individual components without dismantling the automation system CPX-E.
Terminal strips can be removed from the module by disengaging the interlock. An
individual module can be removed from the system by disengaging the module
interlock. The linkage element remains on the H-rail.
1
2
3
4
5
6
7
8
Fig. 2: Module design (example)
1
LED indicators
2
Terminal strips
3
Terminal strip interlock
4
Module interlock
5
Linkage element
6
Functional earth contact FE
7
Housing
8
DIL switch (module-dependent)
4.2.2 Display components
The CPX-E modules have LED indicators specific to the module or to the network
and system:
LED indicators specific to the module and network are described in the docu-
mentation for the that module.
The overview of the system-specific LED indicators is shown in the following
table èTab. 5 System-specific LED indicators.
The response of the system-specific LED indicators is described in:
è11Diagnostics and fault clearance
"Automation system CPX-E manual" è1.1 Applicable documents
System-specific LED indicators
LED Meaning
PS (green) Power System Monitoring of the operating voltage supply
UEL/SEN
PL (green) Power Load Monitoring of the logic and load voltage supply
UOUT
SF (red) System Failure System errors1)
M (yellow) Modify Force mode active or system start with saved
parameterisation and saved system configuration
has been set.
1) Display of 3 error classes by different flashing responses
Tab. 5: System-specific LED indicators
Detailed information on the error classes can be found in the "Automation system
CPX-E manual" è1.1 Applicable documents.
4.2.3 Control elements
The CPX-E module has interlocks for engaging and disengaging the module, con-
nector plugs and connected conductors.
1
2
3
Fig. 3: Control elements
1
Spring-loaded terminal interlock
2
Terminal strip interlock
3
Module interlock
4.2.4 Connecting elements
4.2.4.1 Connecting the automation system CPX-E
The individual modules of the automation system CPX-E are connected to each
other by means of the linking elements. The contact to the linking element is
established when the modules are hung into the H-rail
è6 Mounting.
If a module is removed, the connection to the other modules is interrupted.
4.2.4.2 Connecting the peripherals
For the connection of peripheral equipment, the modules have plug connectors
with spring-loaded terminals è7 Installation.
5 Functional example
1
2
3
4
5
6
Fig. 4: Functional example
1
Higher-order controller
2
Valve terminal VTUG
3
Standards-based cylinder with
proximity switches for position
sensing
4
Flow sensor
5
Indicator light
6
Automation system CPX-E with
bus module and I/O modules