Festo NEDU-L1R2-M12G5-M12LE-1R Manual

Festo Ikke kategoriseret NEDU-L1R2-M12G5-M12LE-1R

Læs gratis den danske manual til Festo NEDU-L1R2-M12G5-M12LE-1R (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 16 personer og har en gennemsnitlig bedømmelse på 4.5 stjerner ud af 8.5 anmeldelser. Har du et spørgsmål om Festo NEDU-L1R2-M12G5-M12LE-1R, eller vil du spørge andre brugere om produktet?

Side 1/1
Translation of the original instructions
© 2020 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product www.festo.com/sp.è
Document Product
User documents IO-Link devices
User documents USB IO-Link Master CDSU-1
Tab. 1
2 Safety
2.1 Safety instructions
Do not connect or disconnect plug connector when powered.
Only mount the product on components that are in a condition to be safely
operated.
Assembly and installation should only be carried out by qualified personnel.
These personnel have electrical training or a relevant qualification.
2.2 Intended use
Connecting a field device with M12 plug to a USB IO-Link Master with additional
supply for port class B.
Field device: IO-Link devices.
USB IO-Link Master: CDSU-1
3 Additional information
Accessories www.festo.com/catalogue.è
4 Configuration
4.1 Product design
1Socket
2Plug
3Wire end (2x)
4Cable
5Wires
Fig. 1 NEDU-L1R2-M12G5-M12LE-1R
4.2 Contact assignment
Field device side Controller side
Pin Signal Pin
1 4 2Socket Controller side Plug connector
1 24 V (L+/Logic) 1
3 0 V (L-/Logic) 3
4 C/Q (IO-Link) 4
Additional supply Wire ends5 3 1)
2 24 VL (P24/load) RD
5 0 VL (N24/load) BK
Open end
1) Colour code in accordance with IEC60757:1983-01
Tab. 2 Contact assignment
5 Assembly
5.1 Assembly, field device side
1. Align socket to match plug.1
2. Connect socket to the plug.1
3. Tighten the screw-type lock of the socket . Tightening torque:1
0.3Nm±67%
5.2 Assembly, controller side
1. Align the plug to match the socket.2
2. Insert the plug into the socket.2
3. Tighten the screw-type lock of the plug . Tightening torque: 0.3Nm±67%2
5.3 Mounting the additional supply
1. Shorten and pre-assemble wire ends as needed.
2. Connect the wires in accordance with the contact assignment.
5.4 Wiring
Character
istic
Cable characteristic Wiring
-P- Basic static
Tab. 3 Wiring
6 Technical data
NEDUL1R2M12G5M12LE1R
Cable characteristic For static applications
Shielding no
Current rating at 40°C [A] 4
Surge resistance [kV] 0.8
Operating voltage rangeDC UB[V] 0…30
Cable composition
Controller side [mm²] 3x0.254
Additional supply [mm²] 2x0.55
Cable diameterD
Controller side [mm] 3.84
Additional supply [mm] 1.755
Bending radiusR
Controller side [mm]4³12
Additional supply [mm]5³6
Ambient temperature
Fixed cable installation [°C] 30… 80z +
Material
Cable sheath TPE-U(PUR)
Insulating sheath PVC
Electrical connection1
Function Field device side
Connection type Socket
Connection technology M12x1 A-coded to EN61076-2-101
Type of mounting Screw-type lock with longitudinal knurl 18ß
Degree of protection IP40 In assembled state
Electrical connection2
Function Controller side
IO-Link
Communication
Connection type Plug connector
Connection technology M12x1 A-coded to EN61076-2-101
Type of mounting Screw-type lock with longitudinal knurl 13ß
Degree of protection IP65, IP68, IP69K In assembled state
Electrical connection3
Function Additional supply for Port Class B
Connection type 2x single wires
Connection technology Open end
Wire ends Cut off bluntly
Tab. 4 Technical data
8136091
NEDUL1R2M12G5M12LE1R
Distributor
8136091
2020-05a
[8136093]
Assembly instructions
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: NEDU-L1R2-M12G5-M12LE-1R

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo NEDU-L1R2-M12G5-M12LE-1R stil et spørgsmål nedenfor, og andre brugere vil svare dig