Festo OVEL-7-H-15-PQ-VQ4-UA-C-A-V1PNLK-R8 Manual
Festo
Ikke kategoriseret
OVEL-7-H-15-PQ-VQ4-UA-C-A-V1PNLK-R8
Læs nedenfor 📖 manual på dansk for Festo OVEL-7-H-15-PQ-VQ4-UA-C-A-V1PNLK-R8 (4 sider) i kategorien Ikke kategoriseret. Denne guide var nyttig for 10 personer og blev bedømt med 4.9 stjerner i gennemsnit af 5.5 brugere
Side 1/4

OVEL
Vacuum generator
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Operating instruction
8194696
2023-08b
[8194698]
8194696
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
IO-Link is a registered trademark of its respective trademark holder in certain
countries.
1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
Documents Product Content
Operating instructions Pressure transmitter SPTE –
Operating instructions Pressure sensor SPAE –
Tab. 1: Applicable documents
2 Safety
2.1 Safety instructions
–Only use the product in its original condition without unauthorised modifica-
tions.
–Before working on the product: switch off the power supply.
–Use the product only inside buildings.
–Take into account the ambient conditions at the location of use.
–The product is intended for use in industrial environments.
The product may generate high frequency interference, which may require
interference suppression measures in residential areas.
–Observe the specifications on the product labelling.
2.2 Intended use
The vacuum generator is used to generate a vacuum.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel have skills and
experience in dealing with electropneumatic (open-loop) control technology.
2.4 UL/CSA certification
In combination with the UL inspection mark on the product, the information in this
section must also be observed in order to comply with the certification conditions
of Underwriters Laboratories Inc. (UL) for USA and Canada.
UL/CSA approval information
Product category code QUYX, QUYX7
File number E322346
Considered standards UL61010-1, CAN/CSA C22.2 No. 61010-1
UL mark
Tab. 2: UL/CSA certification information
WARNING
The unit shall be supplied by a power source which fulfils the requirements on a
limited-energy circuit in accordance to IEC/EN/UL/CSA 61010-1 or on a Limited
Power Source (LPS) in accordance to IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/CSA
62368-1 or a Class 2 circuit in accordance to NEC or CEC.
3 Additional information
–Contact the regional Festo contact if you have technical problems
èwww.festo.com.
–Accessories and spare parts èwww.festo.com/catalogue.
4 Product design
5
6
4
7
8
9
11 10
1
2
3
4
Fig. 1: Product design OVEL-...-H3
1
Supply port for ejector pulse,
optional
2
Supply port
3
Solenoid valve for vacuum gener-
ation
4
Electrical connection, H3
5
Flow control screw to adjust the
intensity of the ejector impulse
6
Solenoid valve for ejector pulse,
optional
7
Vacuum sensor, pressure sensor
optional
8
Exhaust port, optional silencer
9
Vacuum generator cartridge
10
Vacuum port
11
Housing with mounting holes
4
6
7
8
9
10
1
2
3
4
5
11
Fig. 2: Product design OVEL-...-R8
1
Supply port for ejector pulse,
optional
2
Supply port
3
Solenoid valve for vacuum gener-
ation
4
Electrical connection, M8
5
Flow control screw to adjust the
intensity of the ejector impulse
6
Solenoid valve for ejector pulse,
optional
7
Vacuum sensor, pressure sensor
optional
8
Exhaust port, optional silencer
9
Vacuum generator cartridge
10
Vacuum port
11
Housing with mounting hole
5 Function
–The solenoid valve for vacuum controls the supply of compressed air for gener-
ating vacuum. A vacuum is generated so long as the vacuum solenoid valve is in
the switching position.
–The ejector pulse solenoid valve generates an ejector pulse to release the
workpiece safely from the suction cup with connector and to purge the vacuum
quickly. A separate operating pressure can be created for the ejector pulse
through the optional supply port.
–The vacuum sensor monitors the setpoint value for the generated vacuum.

6 Transport and storage
–Store the product in a cool, dry environment protected from UV and corrosion.
Keep storage times short.
7 Assembly
An unfavourable mounting position may impair the function of the product.
• Avoid condensate accumulation in the device through a suitable mounting
position.
• Exhaust air must be able to flow out unhindered.
Direct mounting
• Fasten the vacuum generator with 2 M3 screws.
–Tightening torque: 0.6Nm±20%
Mounting on common supply manifold
The QS fittings are not included with common supply manifold port.
The vacuum generator can be fastened to common supply manifolds with
max.8positions.
Use mounting kit OABM-MK-G3 èwww.festo.com/spareparts.
The vacuum generators with an additional port for ejector pulse (OVEL-...-Z-C-A)
cannot be combined with vacuum generators without an additional port
(OVEL-...-C-A).
1
2
3
Fig. 3: Mounting on common supply
manifold
1
Common supply manifold
2
Connecting adapter
3
Supply port clamping clip
1. Screw the connecting adapter [2] into the common supply manifold [1].
2. Plug the vacuum generator to the connecting adapter and lock it with the
included clamping clip [3].
3. Seal unused positions of the common supply manifold with blanking plugs.
An allocation with OVEL-5 and OVEL-7/-10 is possible only with size 15 common
supply manifolds.
8 Installation
8.1 Pneumatic installation
• Connect tubing to the vacuum generator. Recommendation: use PUN type
tubing èwww.festo.com/catalogue.
Circuit symbols of the vacuum generators with vacuum sensor
OVEL-UA-C-A-... OVEL-UA-Z-C-A-...
OVEL-RQ-C-A-... OVEL-RQ-Z-C-A-...
OVEL-UA-C-... OVEL-RQ-C-...
Tab. 3: Circuit symbols
Circuit symbols for the vacuum generators without vacuum sensor
OVEL-UA-C-A OVEL-UA-Z-C-A
OVEL-RQ-C-A OVEL-RQ-Z-C-A-...
OVEL-UA-C OVEL-RQ-C
Tab. 4: Circuit symbols
8.2 Electrical installation
WARNING
Risk of injury due to electric shock.
• For the electric power supply, use PELV circuits that guarantee a reliable electric
disconnection from the mains network.
• Observe IEC 60204-1/EN 60204-1.
• Connect all circuits for the operating and load voltage supply.
• Connect the vacuum generator to the electrical connection.
–Max. permissible line length: 30m.
Produkt Specifikationer
Mærke: | Festo |
Kategori: | Ikke kategoriseret |
Model: | OVEL-7-H-15-PQ-VQ4-UA-C-A-V1PNLK-R8 |
Har du brug for hjælp?
Hvis du har brug for hjælp til Festo OVEL-7-H-15-PQ-VQ4-UA-C-A-V1PNLK-R8 stil et spørgsmål nedenfor, og andre brugere vil svare dig
Ikke kategoriseret Festo Manualer

10 Januar 2025

10 Januar 2025

7 Januar 2025

7 Januar 2025

6 Januar 2025

6 Januar 2025

6 Januar 2025

21 December 2024

21 December 2024

17 November 2024
Ikke kategoriseret Manualer
- Ikke kategoriseret Kern
- Ikke kategoriseret Eschenbach
- Ikke kategoriseret Pawa
- Ikke kategoriseret Wegman
- Ikke kategoriseret Skandika
- Ikke kategoriseret Freewell
- Ikke kategoriseret Escene
- Ikke kategoriseret Spacedec
- Ikke kategoriseret Oklahoma Sound
- Ikke kategoriseret CaterCool
- Ikke kategoriseret Tivoli Audio
- Ikke kategoriseret Jacuzzi
- Ikke kategoriseret Vimar
- Ikke kategoriseret Alfen
- Ikke kategoriseret Synco
Nyeste Ikke kategoriseret Manualer

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025

8 Juni 2025