Læs gratis den danske manual til Festo VABM-B10-20S-G14-5-P3 (1 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 10 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 5.5 anmeldelser. Har du et spørgsmål om Festo VABM-B10-20S-G14-5-P3, eller vil du spørge andre brugere om produktet?

Side 1/1
Assembly instructions (Original instructions)
8067309
1701b
[8067311]
†‡
Connection block
VABM-B10-20S
Festo SE & Co. KG
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
1. Applicable documents
All available documents for the product www.f
esto.com/pk
2. Safety
Switch off compressed air before mounting work.
Observe tigh
tening torques.
3. Intended use
Pneumatic linking of the valves.
4. Further info
rmation
Accessories for VABM www.fes
to.com/catalogue
5. Scope of delivery
20272d_3
VABM-B10-20S-...
1 Connection block
2 Screw M3x40
1)2)
3 Screw M3x30
1)2)
4 Seal
1)
5 Blanking plug B-1/4
(1x)
(nx)
(nx)
(nx)
(3x)
20272d_4
VABM-B10-20S-...-P3
1 Connection block
2 Screw M3x40
1)2)
3 Screw M3x30
1)2)
4 Seal
1)
5 Blanking plug B-1/4
(1x)
(nx)
(nx)
(nx)
(2x)
6. Not in scope of delivery
20260d_3
6 Solenoid valve
VUVS-… or
pneumatic valve
VUWS-...
1)
(nx)
1)
The number of screws , seals 2 3/4 and valves 6 is dependent on the available valve
positions.
2)
Number = 2 x available valve positions
7. Mounting of blanking plugs 5
5
5
55
20272d_9
Screw in the blanking
plugs 5 at the desired
position, as required.
Blanking plug [Nm]
58.5 _ 15 %
8. Mounting of connection b
l
ock 1
1
1
11
20272d_11
Place connection block 1
on mounting surface (A).
Tighten screws (B).
9. Alignment of seal 4
4
4
44
20272d_8
For valves VUVS-L/LT...:
Place the seal 4 in the
depression of the valve 6
so it is positive-locking.
Observe channel
designation 1/3/5 or 1/3.
20272d_12
For valves VUVS-LK...-S:
Place seal 4 on the
valve 6. Observe channel
designation 1/3/5 or 1/3.
Indexing hole (X) on the
valve 6 is:
only relevant for the
connection block
VABM-B10-20S-...
hidden according to the
alignment of the seal 4.
10. Mounting valve 6
6
6
66
Information
Screws 3 can only be mounted with solenoid valves 6 VUVS-LK…-S.
20272d_10
/Push screws 2 3 into the
drill holes of the valve 6.
Only screws 2 are
loss-protected.
Position valve 6 on the
connection block 1.
Check:
Projection (C) is in the
slot (D)
Valve 6 is aligned parallel
to the surface (E)
Channel designations 1/3/5
or 1/3 agree with each
other.
Tighten screws 2 3/ .
6
1.4 Nm _ 20 %
2
/
3
1
1
5
2
4
1
5
2
4
A
B
6
4
D
1
E
3
3
5
6
4
C
315
6
4
C
315
X
X
X


Produkt Specifikationer

Mærke: Festo
Kategori: Ikke kategoriseret
Model: VABM-B10-20S-G14-5-P3

Har du brug for hjælp?

Hvis du har brug for hjælp til Festo VABM-B10-20S-G14-5-P3 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Festo Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

MuxLab

MuxLab 500439 Manual

5 November 2025
GVM

GVM BL160-II Manual

5 November 2025
Rockville

Rockville SS6 Manual

5 November 2025
MEPROLIGHT

MEPROLIGHT MCO PRO Manual

5 November 2025
XPG

XPG Battlecruiser II Manual

5 November 2025
Hosa

Hosa USQ-110 Manual

5 November 2025