Flojet Triplex 3626 Manual

Flojet Varmepumpe Triplex 3626

Læs gratis den danske manual til Flojet Triplex 3626 (4 sider) i kategorien Varmepumpe. Denne vejledning er vurderet som hjælpsom af 48 personer og har en gennemsnitlig bedømmelse på 4.3 stjerner ud af 24.5 anmeldelser. Har du et spørgsmål om Flojet Triplex 3626, eller vil du spørge andre brugere om produktet?

Side 1/4
“Triplex Diaphragm”
3426 / 3526 / 3626 Series
Automatic Water System Pump
FEATURES
• Self–Priming
• Dry Running
• Soft Noise Absorbing Mounts
• Snap–in Port Fittings
• Built-in Bypass : Less Pulsation
• Reduces need for accumulator tank
• Corrosion Resistant Materials
• Meets ISO 8846 (Ignition protection)
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing
Totally Enclosed. CE Models are
fully suppressed.
Pump: Three chamber diaphragm design
Self-priming up to 9 feet suction lift;
Pump able to run dry without damage Dimensions English (SI)
*CE fully suppressed models are identified by a prefix “R” and a CE mark on the label.(i.e. R3626144).
Self Declaration Of Conformance (SDOC) is available upon request.
OPERATION
With pump switch off and battery fully charged, fill water tank, open all faucets, then turn pump switch on. Water will
begin to flow. When the water is free of air, turn faucets off. Remember, you are filling the water heater and the toilet
and shower lines. When all valves are shut-off, pump will stop. Should pump fail to stop, turn switch off and see the
trouble shooting guide. CAUTION - Pump surface will get hot to the touch if operated for extended periods of time
under pressurized conditions.
2.25"
3.12"
4.24"
4.75"
3.18"
9.04"
(80 mm) (65 mm)
(229 mm)
(80 mm)
(108 mm)
(121 mm)
DIMENSIONAL DRAWING
Model 3426 / 3526 / 3626 Series
Pump Height Length Width Weight
Series inches (mm) inches (mm) inches (mm) Lb (Kg)
3X26XXX 4.75 (121) 9.00 (229) 6.00 (152) 3.50 (1.59)
MODEL* VOLTS AMP DRAW
@10 psi (0.7 bar)
FLOW
GPM (LPM)
PRESSURE SWITCH
Max psi (bar)
BYPASS
03526144 12V dc 4.4 2.9 (11) 50 (3.4) Yes
R3626344 24V dc 2.2 2.9 (11) 40 (2.8) Yes
R3426144 12V dc 4.4 2.9 (11) 25 (1.7) Yes
R3426344 24V dc 2.2 2.9 (11) 25 (1.7) Yes
R3426148 12V dc 3.5 2.0 (8) 25 (1.7) Ye s
R3426348 24V dc 1.7 2.0 (8) 25 (1.7) Ye s
C
A
B
Red (+)
Fuse
(+)
Switch
Battery
Black ( )
-
)
-
)
INSTALLATION WIRING
STEP 1
Remove shipping plugs from pump ports. Some water
from factory testing may spill out.
STEP 2
Connect fittings supplied with the pump to the RV’s
plumbing. Use 1/2’ I.D. Flexible hose (preferably braided
or reinforced) to reduce vibration through the plumbing
system as shown on Fig. 1. Use hose clamps on the
slip-on barb hose connectors.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
horizontally in an accessible location. If mounting
vertically, motor up, attach motor mounts first then pump
head mounts, while supporting weight of pump.
STEP 5
Install inlet A and discharge B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 6
Install a Flojet strainer in an accessible location (for
inspection and cleaning) between the tank and pump
inlet.
This strainer or equivalent is required for pump warranty
to be valid.
STEP 1
Use 14 gauge stranded wire to 20’, 12 gauge to 50’,
from power source.
STEP 2
Use a 10-15 amp rated on-off switch on the (+) positive
(red) motor lead.
STEP 3
Install a 10 amp fuse protection on the positive lead.
FIG. 1
Note: To help reduce noise and vibration of the pump
through the system use flexible lines on the inlet and
outlet of the pump as shown above. Be sure to use
lines rated to not collapse under pump vacuum.
City Water
Inlet
Check
Valve
Flojet Inlet
Strainer
Water
Heater
Water
Tank