Furuno SC-110 Manual


Læs gratis den danske manual til Furuno SC-110 (2 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 35 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 18 anmeldelser. Har du et spørgsmål om Furuno SC-110, eller vil du spørge andre brugere om produktet?

Side 1/2
SC50/110 Satellite Compass Operations and information Quick Guide
Specifications: 12-24 VDC (15 W), Heading [95%] (SC50) ±1.0°, (SC110) ±0.6°, follow-up: 45°/s rate-of-turn, settling time: ~4 minutes
Do not extend standard cables
;
LMR-400
(
u
p
to 60m
)
can also be used
;
label CABLE 1
(
BLK
),
CABLE 2
(
YELLOW
),
CABLE 3
(
RED
)
4.5-inch monochrome
LCD, 120 x 64 dots
Turning the Power On/Off
Use power switch on the processor unit to turn the power to the display unit on and off.
Panel Illumination, Display Contrast (64 levels)- press [DIM] key and omni-pad to adjust.
(If screen is blank, press [DIM] key then “” omni-pad key multiple times to adjust brilliance higher)
Display Modes - Steering, Nav Data, Set and Drift, Compass Rose, ROT, Heading (True only!)
DATUM settings - Confirm WGS84 (default), use when connected to an AIS and/or IMO compliant systems.
WAAS/DGPS Setup - Press the [MENU] key to open the menu. Make changes and press the [ENT] key.
OTHERS MENU
HOLD HDG DATA
Allows displaying of last-used heading data at power on. Indicator flashes, noting un-reliable heading .
HDG RESTORATION
Select GPS signal restore mode, automatically or manually, if lost. Manual restore requires key press.
HDG BACKUP
Select time to display backup data if the GPS signal is lost. This data is also output to external equipment.
Output sentence limitations - IEC 61162-1/2 format (typically compatible with NMEA sentences)
The number of sentences that can be output depends on baud rate and output interval settings.
The maximum number of characters per data sentence is shown in the table below.
Sentences included are HDT, HDM, ROT, ATT, VDR, VTG, GGA, GNS GLL, VHW, VBW, HVE, ZDA
The number of characters that can be output “N” is calculated by the following formula:
N < 0.083 x T x B (Where T = Interval [in seconds] and B = Baud rate (4800 default), 9600, 19200 or 38400
Compliant with: IMO MSC. 116(73), ISO/FDIS 22090-3,IMO A. 694(17), IEC 60945 (2002-08), IEC 61162 (2000)
SC50/110 Operations and Information Quick Guide GP Page 1 3/7/2005


Produkt Specifikationer

Mærke: Furuno
Kategori: Ikke kategoriseret
Model: SC-110

Har du brug for hjælp?

Hvis du har brug for hjælp til Furuno SC-110 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Furuno Manualer

Furuno

Furuno TZTF19F Manual

10 Oktober 2025
Furuno

Furuno FELCOM20 Manual

16 September 2025
Furuno

Furuno GP340 Manual

16 September 2025
Furuno

Furuno FS-1575 Manual

23 Juli 2025
Furuno

Furuno TZTX13X Manual

23 Juli 2025
Furuno

Furuno NX-900 Manual

23 Juli 2025
Furuno

Furuno FM-4800 Manual

23 Juli 2025
Furuno

Furuno MU-152 Manual

23 Juli 2025
Furuno

Furuno GP-39 Manual

23 Juli 2025
Furuno

Furuno FM-8900S Manual

23 Juli 2025

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer

Waterstone

Waterstone 7800 Manual

11 December 2025
Kwikset

Kwikset 258 Manual

11 December 2025
Schlage

Schlage F170 Manual

11 December 2025
Moen

Moen Align 7565EV Manual

11 December 2025
ALNO

ALNO MC10244 Manual

11 December 2025
JET

JET TAK-ZX Manual

11 December 2025
Waterstone

Waterstone 1455 Manual

11 December 2025
Laica

Laica NE2015 Manual

11 December 2025