Læs gratis den danske manual til Garmin GFL 10 (10 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 25 personer og har en gennemsnitlig bedømmelse på 4.7 stjerner ud af 13 anmeldelser. Har du et spørgsmål om Garmin GFL 10, eller vil du spørge andre brugere om produktet?

Side 1/10
GFL 10 Installation and Conguration Instructions
Use the Garmin
®
GFL 10 adapter to adapt analog information provided by a uid-level sensor
on your boat to your NMEA 2000
®
network. The GFL 10 adapter allows you to observe
uid-level information on compatible Garmin display devices connected to your NMEA 2000
network. For a list of compatible Garmin chartplotters and devices, visit www.garmin.com.
Compare the contents of this package with the packing list on the box. If any pieces are
missing, contact your Garmin dealer immediately.
Product Registration
Help us better support you by completing our online registration today. Go to http://my.garmin
.com. Keep the original sales receipt, or a photocopy, in a safe place.
Contact Garmin
Contact Garmin Product Support if you have any questions while using your GFL 10 adapter. In
the USA, go to www.garmin.com/support, or contact Garmin USA by phone at (913) 397.8200
or (800) 800.1020.
In the UK, contact Garmin (Europe) Ltd. by phone at 0808 2380000.
In Europe, go to www.garmin.com/support and click for in-country support Contact Support
information, or contact Garmin (Europe) Ltd. by phone at +44 (0) 870.8501241.
See the Important Safety and Product Information guide in the compatible Garmin display device box for
product warnings and other important information.
CAUTION: Always wear safety goggles, ear protection, and a dust mask when drilling, cutting, or
sanding.
NOTICE: When drilling or cutting, always check the opposite side of the drilling or cutting
surface.
Needed Tools and Supplies
Heat-shrink tubing and a heat gun
Cable ties
Additional NMEA 2000 cabling and connectors (optional)
July 2009 190-01081-06 Rev. A Printed in Taiwan
 GFL10InstallationandCongurationInstructions
Determining an Installation Location
When you are selecting a location to install the GFL 10 adapter, consider the following:
During installation, you connect the GFL 10 adapter to the analog gauge (or directly to the
uid-level sensor), and to the NMEA 2000 network. Therefore:
Choose a location that is within 173 in. (4.4 m) of the analog gauge (or the uid-level
sensor) to avoid splicing bare wires.
Choose a location between the NMEA 2000 backbone and the analog gauge (or the uid-
level sensor).
If you cannot connect the adapter directly to the NMEA 2000 network, add a drop cable.
See page 3 for more information.
The adapter is IEC 60529 IPX7 waterproof, and can be submerged up to 30 minutes at 1
meter. Do not install the adapter in a location where it will be submerged regularly, though
the location can be subject to wash-down.
You can use cable ties (not included) to secure the adapter to an existing structure on your
boat.
You can use mounted-head cable ties (not included) and screws (not included) to secure the
adapter to a bulkhead or other suitable surface on your boat.
Install the adapter at least 2 in. (5 cm) from a magnetic compass to prevent electromagnetic
interference, which can cause inaccurate compass readings.
Wiring the GFL 10 Adapter
Connect the GFL 10 adapter either to an analog gauge or to the sender directly using the bare
wires on the wiring harness.
Wiring the GFL 10 Adapter to an Analog Gauge
If your boat has an analog gauge representing the uid level, you can wire the GFL 10 adapter
directly to the gauge. Consult the owners manual provided by your boat or sensor manufacturer
to determine the ground, sensor, and power (ignition) connections on the gauge. Typically,
the power (ignition) connector is labeled with a “+”, a “+12V”, an “I”, or an “IGN” marking.
The ground connector is typically labeled with a “-”, a “ ”, or a “G” marking, and the sensor
connector is typically labeled with an “S” or a “G” marking. Do not remove any wires from the
back of the gauge, and wire the GFL 10 adapter to the gauge according to the following table.
Wiring the GFL 10 Adapter Directly to a Fluid-Level Sensor
If your boat does not have an analog gauge representing the uid level, you can wire the adapter
directly to the uid-level sensor. Consult the owner’s manual provided by your boat or sensor
manufacturer to determine the sending and ground terminals on the sensor. Typically, the
sending terminal is labeled with an “S” marking for sensor or a “G” marking for gauge, and the
ground terminal is typically labeled with a negative sign (-). Wire the GFL 10 adapter to the
sensor according to the following table.


Produkt Specifikationer

Mærke: Garmin
Kategori: Ikke kategoriseret
Model: GFL 10

Har du brug for hjælp?

Hvis du har brug for hjælp til Garmin GFL 10 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret Garmin Manualer

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer