GE GNULQ Manual


Læs gratis den danske manual til GE GNULQ (16 sider) i kategorien Ikke kategoriseret. Denne vejledning er vurderet som hjælpsom af 28 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 14.5 anmeldelser. Har du et spørgsmål om GE GNULQ, eller vil du spørge andre brugere om produktet?

Side 1/16
1
TOOLS YOU WILL NEED
Installation
Kitchen and Bath Main Faucet
Instructions
Filtration System GXULQ/GNULQ
SAFETY PRECAUTIONS
Check with your state and local public works
department for plumbing and sanitation codes.
You must follow these guidelines as you install
the Kitchen and Bath Main Faucet Filtration
System. Using a qualified installer is recommended.
Be sure the water supply conforms with the
Performance Data. If the water supply conditions are
unknown, contact your municipal water company.
WARNING
Do not use with water that is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
It is highly recommended that a water shut-off valve
be placed directly upstream of your Kitchen and Bath
Main Faucet Filtration System.
PARTS INCLUDED
Filter Cartridge
Filter Head/Bracket
6 Feet of 3/8” Tubing
3/8 x 1/2” Faucet Adapter
3/8 Compression Hex Nut
3/8 Ferrule
3/8 Tube Insert
Mounting Screws
1/2 Compression to 3/8” Adapter
7/16” Compression to 3/8” Adapter
Optional accessories are available (Visa, MasterCard or
Discover cards accepted) by visiting our Website at ge.com
or from Parts and Accessories, call 800.626.2002 (U.S.) or
800.663.6060 (Canada).
Adjustable Wrench
Utility Knife
Phillips-Head
Screwdriver
49-50225-4 06-10 GE Printed in China
PROPER INSTALLATION
This Kitchen and Bath Main Faucet Filtration System
must be properly installed and located in
accordance with the Installation Instructions before
it is used.
Check with your local public works department for
plumbing codes. You must follow their guides as
you install the Kitchen and Bath Main Faucet
Filtration System.
Use the Kitchen and Bath Main Faucet Filtration
System on a potable, safe-to-drink, home COLD
water supply only. The filter cartridge will not
purify water or make unsafe water safe to drink.
DO NOT use on HOT water (100°F max).
Protect the Kitchen and Bath Main Faucet
Filtration System and piping from freezing. Water
freezing in the system will damage it.
Your Kitchen and Bath Main Faucet Filtration
System will withstand up to 100 psi water
pressure. If your house water supply pressure is
higher than 100 psi during the day (it may reach
higher levels at night), install a pressure reducing
valve before the system is installed.
Do not install on HOT WATER. The temperature
of the water supply to the Kitchen and Bath Main
Faucet Filtration System must be between the
minimum of 3F and the maximum of 100°F.
See the Performance Data section.
Do not install the Kitchen and Bath Main Faucet
Filtration System using copper solder fittings.
The heat from the soldering process will damage
the unit.
WARNING Discard all unused parts
and packaging material after installation. Small parts
remaining after installation could be a choke hazard.
Do not install filter in an outside location or
anywhere it will be exposed to sunlight.
System is
Tested and Certified by NSF International
against NSF/ANSI
Standard 42 for the reduction of
Chlorine, Taste and Odor and Particulates Class I and
against CSA B483.1.
Drill with 1/8” Drill Bit
HOT COLD
IN
OUT
Optional installation
STEP-BY-STEP
I
NSTAL
LATION I
N
ST
RU
CTIONS
Installation Overview
NOTE: Be sure to allow a minimum space of 11/22
under the system for removing the filter cartridge.
If you have copper tubing with 3/8compression fittings,
you’ll need to follow Step 3 Option B (Optional Installation).
CARTRIDGE SPECIFICATIONS
Performance Data – Filtration System GXULQ Using Filter GXULQR
nThis System has been tested according to NSF/ANSI 42 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in NSF/ANSI 42.
nActual performance may vary with local water conditions.
nDo not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after
the system.
2
Installation Instructions
FILTER CARTRIDGE REPLACEMENT
Replacement Filter Canister/Estimated Replacement Costs
GXULQRReplacement filter canister $29–34
For replacement parts, call toll-free 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
TO REMOVE FILTER:
Turn filter 1/4 turn to the left. The top surface of
the filter will move away from the bottom of the
head. Pull the filter down to remove.
HOT COLD
IN
OUT
Filter
Cartridge
INSTALLING THE SYSTEM
SELECT A LOCATION
Select a location for the system that is:
Protected from freezing.
Not exposed to direct sunlight.
Select and mark a location under the sink that allows
access for a filter cartridge change. See Section 4.
The system can be mounted vertically or horizontally.
DO NOT MOUNT THE SYSTEM UPSIDE DOWN.
B
A
1
DISCONNECT COLD WATER SUPPLY
Remove items from under the sink. Place a
bucket and some towels under the sink to collect
any water that may run out when disconnecting
the water supply lines.
Turn off the cold water supply valve and remove
the existing water supply tubing and fittings.
NOTE:
For copper tubing, leave the 3/8compression
fitting on the faucet stem. Go to Step 3, Option B.
B
A
2
3/8” x 1/2” Push to
Connect Adapter Filter Head/
Bracket
Standard No. 42: Aesthetic Effects
USEPA Influent Influent Effluent % Reduction Reduction
Parameter MCL Challenge Concentration Average Average Maximum Average Minimum Requirement
Chlorine taste and odor 2.0 mg/L ± 10% 1.9 mg/L <0.05 mg/L 0.05 mg/L >97.4% 97.4% ≥50%
Particulate, Class I
particles 0.5 to <1um**
≥10000 particles/mL 10333333 #/mL 20,500 #/mL 41,000 #/mL 99.8% 99.6% ≥85%
*Tested using a flow rate of 2 gpm (7.6 l/min); pressure of 60 psig; Operating Specifications
pH of 7.5 ± 0.5; temp. of 6± 5°F (20° ± 3°C) Capacity: certified for up to 2000 gallons (7,571 l); up to six months
**Measurement in particles/mL. Particles used were 0.5–1 microns. Pressure requirement: 20–100 psi (1.4–6.9 bar)
Temperature: 34°–100°F (1.1°–38°C)
FILTER CARTRIDGE REPLACEMENT (cont.)
TO REPLACE FILTER:
Push filter into the filter head/bracket. Turn filter
1/4 turn to the right until it stops. The top surface
of the filter will be flush with the bottom of the filter
head/bracket when fully installed.
NOTE: When correctly installed, the label will face out.
Turn on the cold water faucet to flush the filter for
5 minutes to remove air.
Change the batteries in the timer.
NOTE: Remove the water in the line to minimize the water released
during filter cartridge replacement. Turn off the cold water supply
valve and turn on the faucet for 5 seconds.
C
B
A
Shut-Off Valve
Ferrule
Hex nut
Tubing
insert


Produkt Specifikationer

Mærke: GE
Kategori: Ikke kategoriseret
Model: GNULQ

Har du brug for hjælp?

Hvis du har brug for hjælp til GE GNULQ stil et spørgsmål nedenfor, og andre brugere vil svare dig




Ikke kategoriseret GE Manualer

GE

GE GFC325N Manual

9 December 2024
GE

GE ZXR7510C Manual

6 Oktober 2024
GE

GE GXITD Manual

16 September 2024
GE

GE ZWSP42D Manual

19 August 2024
GE

GE ZGW124ENSS Manual

13 August 2024
GE

GE GNULQ Manual

9 August 2024
GE

GE ZX27CTYSS Manual

6 August 2024

Ikke kategoriseret Manualer

Nyeste Ikke kategoriseret Manualer