Instructions for Installation
Smoke detector plus / VdS 02/02 Seite: 1 von 6
pure white Art. Nr.: 0496 06
alu 0496 07
Smoke detector plus / VdS with radio transmitter module
pure white Art. Nr.: 0496 08
alu 0496 09
Product features
Battery-operated stand-alone Home Smoke Detector working on photoelectric principle.
Automatic self-test for smoke-sensing electronics, therefore extremely reliable and immune to
interference.
Option of operating as a wireless network with radio transmitter modules and a wireless alarm unit
(available as extras).
Loud pulsating warning tone if smoke detected, approx. 85 dB (A).
Battery low-power monitor (LED and short beeps at intervals) warns that battery voltage is
growing weaker, for up to about 30 days.
Contamination/fault warning function with LED and short beep.
Option of operating as a wired network with relay modules (available as extras). Up to 40 smoke
detectors can be linked together. If one smoke detector identifies a fire, the alarm is relayed all the
other smoke detectors in the network.
Integrated test button: if the smoke detector emits its warning tone when the test button is
pressed, it is in good working order.
Simple mechanical safeguard prevents smoke detector clicking into place in its base if no battery
is fitted.
Damage to the detector is not possible if the battery is installed with the wrong polarity.
Operating principle
The smoke detector is an early warning device for smouldering fires as well as flaming fires that
develop smoke. It operates on the proven light scatter principle. lnside the sensing chamber a light
source and a light sensor are arranged so that light normally does not fall on the sensor. It is only
when airborne particles enter the chamber that light is scattered onto the sensor (Tyndall effect) to
produce an electrical signal. This design means that no radioactive source is required. Smouldering
fires in particular are quickly identified by the smoke detector and the alarm given.
If smoke enters the sensing chamber, the built-in sounder is triggered. A logic circuit to eliminate false
alarms delays the alarm signal and resetting by up to 30 seconds.
This product has been approved by the Schadenverhütung GmbH in Cologne (VdS). Only security
products meeting the high quality demands of the prEN 12239 receive this approval.
Important test criteria are:
reliable smoke detection characteristics
good smoke entry
immunity to electrostatically discharge
functional check and battery presence control
Test button


Produkt Specifikationer

Mærke: Gira
Kategori: Røgalarm
Model: 0496 06

Har du brug for hjælp?

Hvis du har brug for hjælp til Gira 0496 06 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Røgalarm Gira Manualer

Gira

Gira 0496 06 Manual

23 Juli 2025

Røgalarm Manualer

Nyeste Røgalarm Manualer

Alecto

Alecto SD530 Manual

10 November 2025
SAVS

SAVS SA5MA Manual

8 November 2025
Alecto

Alecto SD110 Manual

4 November 2025
Kidde

Kidde 30CUA10-VCA Manual

2 November 2025
Alecto

Alecto BPB21 Manual

1 November 2025
Alecto

Alecto SD1010 Manual

1 November 2025
SAVS

SAVS SA5MB Manual

31 Oktober 2025
First Alert

First Alert CO615 Manual

23 Oktober 2025
X-Sense

X-Sense SD11 Manual

9 Oktober 2025