Læs gratis den danske manual til Hikvision DS-2TD2636B-13/P (1 sider) i kategorien fotokamera. Denne vejledning er vurderet som hjælpsom af 3 personer og har en gennemsnitlig bedømmelse på 5.0 stjerner ud af 2 anmeldelser. Har du et spørgsmål om Hikvision DS-2TD2636B-13/P, eller vil du spørge andre brugere om produktet?

Side 1/1
Highly Accurate Thermographic Camera
Installation and Conguration Guide
Temperature Measurement Range: 86 113 30 45 F (  C)
Working Temperature: 50 95 10 35 F (  C)
Accuracy: ± ±0.9F ( 0.5C)
Resoluon: 384 ×288
1
Installation
Wall-Mounted Deployment
2
Recommended Installaon Parameters
Model
Distance
(between human
and
camera)
Height
Elevaon
Angle
DS
-2TD2636B-
13/P
8' 2"23'
(2.5 m 7 m)
5' 7" 82"
(1.7 m
2.5 m)
20°
3
Advice
1. Select Body Thermometry as VCA Resource Type.
2. Go to Conguraon > Local interface, enable and save
the following sengs:
3. Go to Body Thermometry > Basic Setngs. Congure
and save the following setngs:
Emissivity: For human skin, this value is normally set as 0.98.
Distance: The actual distance between the camera and
human.
Check Enable Face Detecon and Display Temperature.
Suggest uncheck Upload Captured Face Image Display Face and
Temperature Posion if its not required.
Set Alarm Temp. Pre-alarm Temp.and
Press Draw Area to adjust face detecon region.
Click Max. Pupil Distance Min. Pupil Distance and to draw
width lter frame. Max and Min distance refer to camera
detecon distance.
4. Congure Camera 01 (Opcal) Setngs.
Uncheck Enable Blackbody Correcon if no blackbody is used.
Check Enable of Body Temperature Compensaon, and keep
parameters as default.
DS-2TD2636B
The environment can easily inuence the performance of thermal cameras Therefore, thermal cameras are .
required to be used in a stable indoor environment without wind, and the ambient temperature should be
consistent.
Here s some advice:
1. Set up a one-way screening zone, and ensure that the camera can clearly see the face of the person whose
skin-surface temperature is being measured.
2. Avoid backgrounds that are too crowded or bright.
3. Turn the camera on minutes before taking skin-surface temperature measurements because the camera 30 ,
needs to be stable.
4. If there is a large dierence between the indoor and outdoor temperatures it is suggested to wait more than ,
ve minutes before measuring the skin-surface temperature of someone who just got in.
5. Follow the guidance of required temperature measurement distance and height.
5. Congure Camera 02 (Thermal) Setngs.


Produkt Specifikationer

Mærke: Hikvision
Kategori: fotokamera
Model: DS-2TD2636B-13/P
Brugervejledning: Ja
Ethernet LAN-porte (RJ-45): 1
Ethernet LAN: Ja
Webbrowser: Ja
Forbindelsesteknologi: Ledningsført
Understøttede netværksprotokoller: IPv4/IPv6, HTTP, HTTPS, 802.1x, Qos, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
IP-adresse filtrering: Ja
Video komprimeringsformater: H.264, H.265
Understøttet placering: Udendørs
Sensortype: CMOS
Progressiv scanning: Ja
Voice codecs: G.711, G.722.1, G.726, MP2L2, PCM
Minimumsbelysning: 0.001 Lux
Optisk sensorstørrelse: 1/2.7 "
Ethernet-grænsefladetype: Hurtigt ethernet
HTTPS -kryptering: Ja
Kameraets lukkerhastighed: 1/100 sek./side
Videostreaming: Ja
Antal sprog: 32

Har du brug for hjælp?

Hvis du har brug for hjælp til Hikvision DS-2TD2636B-13/P stil et spørgsmål nedenfor, og andre brugere vil svare dig