Læs gratis den danske manual til Honeywell HPA094 (12 sider) i kategorien Luftrenser. Denne vejledning er vurderet som hjælpsom af 14 personer og har en gennemsnitlig bedømmelse på 4.6 stjerner ud af 7.5 anmeldelser. Har du et spørgsmål om Honeywell HPA094, eller vil du spørge andre brugere om produktet?

Side 1/12
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS
AIR PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the
air purifier.
2. Place air purifier where it is not easily
knocked over by persons in the household.
3. Always turn the air purifier controls to the
OFF position and unplug from the wall
outlet when not in use.
4. To disconnect the air purifier, make sure
the unit is powered OFF then grip the plug
and pull it from the wall outlet. Never pull
by the cord.
5. Do not use any product with a damaged
cord or plug or if product malfunctions, is
dropped or damaged in any manner. Keep
the cord away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is
fully assembled.
8. Do not run power cord under carpets, and
do not cover with throw rugs. Arrange
cord such that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or
use near water, in a bathroom, laundry
area or other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter
ventilation or exhaust opening as this may
cause electric shock or damage to the air
purifier. Do not block air outlets or intakes.
13. Locate air purifier near the outlet and
avoid using an extension cord.
14. This appliance has a polarized plug (one
blade is wider than the other). To reduce
the risk of shock, this plug is intended to
fit only one way in a polarized outlet. If the
plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a
qualified electrician.
DO NOT attempt to defeat this safety
feature.
15. A loose fit between the AC outlet
(receptacle) and plug may cause
overheating and a distortion of the plug.
Contact a qualified electrician to replace
loose or worn outlet.
16. Do not sit, stand or place heavy objects on
the air purifier.
17. Disconnect power supply before servicing.
18. SAVE THESE INSTRUCTIONS.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
THE DOCTOR’S CHOICE
TRUE HEPA
ALLERGEN REMOVER
AIR PURIFIERS
For Models: HPA090 series, HPA100 series,
HPA200 series & HPA300 series
The Honeywell Trademark is used by Kaz USA, Inc. under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
2 3
HPA100 series, HPA200 series, HPA300 series
Type
R
A
A
R
Odor Reducing Pre-Filter
or
R
A
A
R
Household Gas
& Odor Reducing Pre-Filter
Front Grille
YOUR AIR PURIFIER
SET-UP
Select a firm, level and flat location.
When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may
also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug
should be used underneath to prevent permanent staining. This is especially important in homes with
contamination from smoking, fireplaces, or where candles are burned.
Ensure the front of the unit faces away from the closest wall or furniture.
Ensure no grilles are blocked.
Control Panel
HPA090 series
Type R
AA
R
True HEPA
Filter (1)
Type
R
AA
R
Odor Reducing
Pre-Filter or
R
A
A
R
Household Gas &
Odor Reducing Pre-Filter
Front Grille
The True HEPA Filters and Odor Reducing Pre-Filter are supplied within the air purifier. New air purifiers
have their filters wrapped to ensure purity, and are labeled to help identify the proper replacement filter.
(Type
R
AA
R
True HEPA Filter; Type
R
AA
R
Odor Reducing Pre-Filter or
R
AA
R
Household Gas & Odor Reducing Pre-Filter)
• Before using your new air purifier you must remove the wrappers covering the filters and Pre-Filter.
Make sure the air purifier is OFF and unplugged. Press the two hand symbols () on the front grille to
release it from the unit and pull the grille toward you to remove it (see Fig. 2). Grasp the sides of the
filter frame near its top end and pull outward. Repeat for the second and third
filter if applicable.
• Remove protective wrap from the filters (including the Pre-Filter) that have
been supplied with your air purifier.
• Place the HEPA filter(s) into the air purifier housing. Ensure that the removal
pull” tabs are facing outward (this will facilitate filter removal later). Place the
Pre-Filter on top of the HEPA filter(s). Tuck the edges of the Pre-Filter into the
tabs that are located around the edges of where the HEPA filter(s) are inserted.
This will hold the Pre-Filter securely in place.
• Replace the front grille by placing the tabs on the bottom of the grille into the
slot(s) on the unit. Gently push the top of the grille into place by pressing on the hand symbols () to
secure in place.
Control Panel
Type R
AA
R
True HEPA Filters
HPA100 HPA300HPA200
HOW YOUR AIR PURIFIER WORKS
This model air purifier incorporates a 2-stage cleaning
system to help clean the air that passes through the
filter in the unit (Fig. 1).
Stage 1: Odor Reducing Pre-Filter
Stage 2: True HEPA Filter that captures
particles as small as 0.3 microns or larger
2
Filter(s)
Odor Reducing
Pre-Filter
STAGE 1 STAGE 2
Fig. 1
SET-UP
INSTALL TRUE HEPA FILTERS AND ODOR REDUCING PRE-FILTER
Fig. 2


Produkt Specifikationer

Mærke: Honeywell
Kategori: Luftrenser
Model: HPA094

Har du brug for hjælp?

Hvis du har brug for hjælp til Honeywell HPA094 stil et spørgsmål nedenfor, og andre brugere vil svare dig