Jabsco 23680-4003 Manual

Jabsco Pumpe 23680-4003

Læs gratis den danske manual til Jabsco 23680-4003 (2 sider) i kategorien Pumpe. Denne vejledning er vurderet som hjælpsom af 64 personer og har en gennemsnitlig bedømmelse på 4.8 stjerner ud af 32.5 anmeldelser. Har du et spørgsmål om Jabsco 23680-4003, eller vil du spørge andre brugere om produktet?

Side 1/2
MODELS:
23680-4003 12V DC
23680-4103 24V DC
COMMERCIAL DUTY
WATER PUPPY
FEATURES:
Continuous rated, medium duty pumps for
bilge and general purpose use.
lISO 8846 MARINE (Ignition protection).
lISO 8849 MARINE (Bilge pump standard).
lSmall bilge debris present no problem to
these bronze bodied, flexible impeller
pumps.
lSimple design means fewer wearing
parts.
l32 lpm (6.5 UK gpm) output @ 3m (10ft)
head.
lSelf priming to 1.2m (4 ft).
INSTALLATION INSTRUCTIONS:
Jabsco Water Puppy can be mounted on any flat
surface. Fit the pump in a dry, well ventilated
position where there is full access for service. If
installed in a vertical position the motor must be
above the pump head. Use the rubber grommets
provided to minimise vibration, do not overtighten the
mounting screws.
Secure 25mm (1”) id hose either direct to the
discharge ports or to ½” BSP male threaded fittings
using stainless steel hose clamps. Use spiral
reinforced hose (with a smooth internal bore) that will
not collapse under suction, or rigid or semi rigid
pipework systems. The pipework must be compatible
with the liquid being pumped. Pipe runs should be
kept as straight and short as possible, avoiding rising
and dipping over obstructions. Fit a strainer on the
inlet hose to prevent larger debris from entering the
pump.
WIRING INSTRUCTIONS
Make all electrical connections in dry locations,
connections in humid environments should be sealed
to prevent corrosion. Protect the circuit with a
correctly rated fuse or circuit breaker in the orange
positive (+) lead as close as possible to the power
source. Connect the black motor wire to the negative
(-) battery terminal. Inadequate voltage at the motor
terminals when the pump is running (not less than
10% below rated voltage at full load) due to partially
discharged batteries or insufficient cable size may
result in blowing fuses, failure to start or poor pump
performance.
WARNING: If the fuse fails
repeatedly do not fit a heavier fuse or
bridge the fuse terminals with silver
paper or metal wire. Failure to observe
this instruction may result in a fire
hazard due to overheating of cables.
WARNING: All marine pumps
discharging overboard must be
installed with the overboard discharge
well above both static and heeled
waterlines.
m ft lpm UK gpm
2 7 35 7.7
3 10 32 7
4 13 30 6.6
6 20 25 5.5
WATER PUPPY PERFORMANCE
TOTAL HEAD
WATER PUPPY
Approximate performance for new pump,
running water at 20°C with fully charged battery
WARNING: Do not use any Jabsco
pump for petrol, petroleum products or
any products with a flash point below
37°C (98°F), explosion or death may
occur.
MODEL
NO.
VOLTAGE
MAXIMUM
AMP
DRAW
MAXIMUM
FUSE
SIZE
MAXIMUM LENGTH
BETWEEN (+) & (-)
BATTERY TERMINALS
23680-4003 12 volt 13 amp 15 amp
4.5m (15ft) *
32 / 0.2mm
(1.0mm²)
ELECTRICAL WIRING INFORMATION
23680-4103
24 volt
6 amp
10 amp
4.5m (15ft) *
DIMENSIONAL DRAWING & PARTS LIST
WEIGHT: Water Puppy - 3.0kg (6.6lb)
Warranty: All products of the company are sold and all services of the company are offered subject to the company’s warranty and terms and conditions of sale, copies of which will be furnished upon request.
© 2011 Xylem, Inc Rev B 11/2012
100 Cummings Center, Ste 535-N, Beverly, MA 01915
+1 978 281 0440 +1 978 283 2619
KEY DESCRIPTION QUANTITY PART NO.
1 End Cover Screw * 3 SP1004-09
2 End Cover 1 9328-0200
3 Impeller * 1 6303-0003
4 O-ring * 1 X5251-049
5 Body 1 23064-2100
6 Seal * 1 SP2701-52
7 Screw (pump to motor) 2 X3001-147F
8 Slinger 1 6342
Motor 12V 1 74001-2652B
Motor 24V 1 74001-2653B
SK224
WATER PUPPY PART LIST
Service Kit (Contains Items Marked *)
9
* For longer installations, fit thicker cables


Produkt Specifikationer

Mærke: Jabsco
Kategori: Pumpe
Model: 23680-4003

Har du brug for hjælp?

Hvis du har brug for hjælp til Jabsco 23680-4003 stil et spørgsmål nedenfor, og andre brugere vil svare dig




Pumpe Jabsco Manualer

Jabsco

Jabsco Par-Max HD4 Manual

26 Januar 2024
Jabsco

Jabsco 31820-0492 Manual

24 December 2023
Jabsco

Jabsco Par-Max 3 Manual

9 September 2023

Pumpe Manualer

Nyeste Pumpe Manualer

Flo

Flo 79811 Manual

16 Juni 2025
Flo

Flo 79880 Manual

16 Juni 2025
Flo

Flo 79944 Manual

10 Juni 2025
Flo

Flo 79771 Manual

9 Juni 2025
Flo

Flo 79812 Manual

9 Juni 2025
Flo

Flo 79772 Manual

9 Juni 2025
Flo

Flo 79775 Manual

9 Juni 2025
Flo

Flo 79773 Manual

9 Juni 2025
Flo

Flo 79774 Manual

9 Juni 2025
Flo

Flo 79810 Manual

9 Juni 2025