Læs gratis den danske manual til Jøtul GI 635 DV IPI Newcastle (52 sider) i kategorien Pejs. Denne vejledning er vurderet som hjælpsom af 19 personer og har en gennemsnitlig bedømmelse på 3.5 stjerner ud af 10 anmeldelser. Har du et spørgsmål om Jøtul GI 635 DV IPI Newcastle, eller vil du spørge andre brugere om produktet?

Side 1/52
1
139712_F GI 635 IPI 7/21
Installation and
Operation Instructions
Jøtul GI 635 DV IPI
Newcastle
Direct Vent Fireplace Insert
Pilot-on-Demand Ignition
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
In the Commonwealth of Massachusetts,
a carbon monoxide (CO) detector shall be
installed in the same room as the appliance.
WARNING:
FIRE OR EXPLOSION HAZARD. Failure to follow
safety warnings exactly could result in serious injury,
death, or property damage.
This appliance may be installed in an aftermarket,
permanently located, manufactured home or mobile
home, where not prohibited by local codes.
This appliance is only for use with the types of gas
indicated on the rating plate. A conversion kit is supplied
with the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.











Certified to ANSI Z21.88-2016 • CSA 2.33-2016 and
CAN/CGA 2.17-M-17.
2
139712_F GI 635 IPI 7/21
62.29%
Natural Gas
Jøtul GI 635 DV IPI
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI
Gas Specialists.
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER OR JOURNEYMAN
PLUMBER OR GASFITTER WHEN
INSTALLED IN THE COMMONWEALTH
OF MASSACHUSETTS.
1. If there is not one already present, on each
floor level where there are bedroom(s), a
carbon monoxide detector and alarm shall
be placed in the living area outside the
bedroom(s). The carbon monoxide detector
shall comply with NFPA 720 (2005
Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery powered
or both; and
c) Shall comply with NFPA 720 (2005
Edition).
3. A Product-approved vent terminal must be
used, and if applicable, a Product-approved
air intake must be used. Installation shall be
in strict compliance with the manufacturer’s
instructions. A copy of the installation
instructions must remain with the appliance
or equipment at the completion of the
installation.
Suggested Tools for Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shut-o valve -
T-Handle required in Massachusetts
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10 mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
Work Gloves
Safety glasses
Torx T-20 screwdriver
• Tin snips
THIS OWNERS MANUAL PROVIDES INFORMATION
TO ENSURE SAFE INSTALLATION AND EFFICIENT,
DEPENDABLE OPERATION OF YOUR FIREPLACE
INSERT. PLEASE READ THESE INSTRUCTIONS IN THEIR
ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE
USING OR SERVICING THIS GAS INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE
CONSTRUCTION OF THIS APPLIANCE OR ITS
COMPONENTS. ANY MODIFICATION OR ALTERATION
WILL VOID THE WARRANTY, CERTIFICATION AND
LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY
A QUALIFIED SERVICE AGENCY.
63.67%
Propane
PLEASE NOTE:
Initial Break-in
It is normal for smoke and odor to occur during the initial stages
of operation, depending upon temperatures generated over time.
This “curing” condition can be alleviated by promoting fresh air
circulation within the immediate vicinity of the appliance.
Operation Sound
Please be aware that cast iron and steel components expand
and contract with temperature fluctuations that are often
accompanied by “creaking” or “pinging” sounds. This is the result
of natural thermal activity.
The optional blower fan will also
generate a slight hum at the low
setting and progressively increase
with the velocity of forced air.
Based on CSA P.4.1-15